Dongguan Tangxia Precision Instrument Factory
Home>Products>JG8001-O2 Oxygen Concentration Analyzer
JG8001-O2 Oxygen Concentration Analyzer
JG8001-O2 Oxygen Concentration Analyzer
Product details

JG8001-O2 Oxygen Concentration Analyzer


oxygenanalysisinstrumentbrief introduction

oxygenanalysisinstrumentUsed for mobile devices that require detection and analysis of oxygen concentrationOccasions for temperature and humidity measurementgas analyzeruseReal time display of concentration on 3.5-inch clear color screenWe use the best products in the current industryelectrochemistryOr infrared, catalytic combustion, thermal conductivityPID photoionizationPrinciple of gas sensorSwiss precision capacitive digital temperature and humidity sensor.It can detect and analyze gas concentrations in pipelines, confined spaces, and atmospheric environments, as well as detect gas leaks, detecting gas types exceeding500 types, and can also detect and analyze various background gases such as nitrogen or oxygenconcentrationSingle gasPurity.

oxygenanalysisInstrument features:

● WaterproofsplashDustproofExplosion proof and shock resistantIntrinsic safety circuitdesign, anti-static, anti electromagnetic interference

Don't protect yourselfIP66, Built in water vapor and dust filters to prevent sensor and instrument damage caused by water vapor and dust

Built in pump suction measurement,Quick responseThe sampling distance is greater than10 meters,Special gas path design

The 3.5-inch clear color screen displays real-time concentration, alarm, time, temperature, humidity, storage, communication, and printing

high-capacityData storage function, with a standard storage capacity of 100000 pieces of data, and larger capacities can be customized.

Automatic recognition of infrared communication interface, USB interface, RS232 interface, optional built-in or external wireless infrared printer

USB charging interface, can be charged with a computer or power bank, compatible with mobile phone chargers, overcharge, overdischarge, overvoltage, short circuit

● Adopting10000mALarge capacity rechargeablenumeratorpolymerBattery, capable of long-term continuous operation

● Sound and lightAlarm, visual alarm, undervoltage alarm, fault alarm, and multi-directional stereoscopic display of alarm status during alarm.

The alarm value can be set,The alarm mode can be selected as low alarmAlarm, interval alarm, weighted average alarm

● AccuracyTemperature and humidity measurement (optional), along with temperature compensation for the sensor, within the temperature range of the instrument-4070 degrees

Low can be detected0.001PPM,approvedetection99.999%Vol,Support low range automatic switching (to be specified when ordering).

It can be detected in real-time or timed (for situations where the amount of gas being measured is relatively small), and the pump can be turned off to extend the start-up time when not detected.

Optional simultaneous detection of 16 typesGas, expanded to 18 types, units can be freely switched,Conventional gases do not require input of molecular weight, while special gases do

Automatically calculate and switch based on the required molecular weight input, with units available for selection:PPM、mg/m3、Vol%、LEL%、PPHM、ppb、mg/L

threeSwitchable display modes: simultaneous display of four gas concentrations, large font cyclic display of single channel gas concentration, real-time curve

The Chinese and English interfaces are selectable, with the default Chinese interface,Concise Chinese or English operation tips, easy for users of all ages to operate

● Data recovery function,Selective or full recovery is possible, and concentration calibration errors are automatically identified and prevented to avoid adverse effects caused by human factors

Zero point automatic tracking, multi calibration of target points, ensuring measurement linearity and accuracy, and meeting both standards and local metrology bureau standards.

Capable of recording calibration logs, maintenance logs, troubleshooting strategies, sensor lifespan expiration reminder, and next concentration calibration time reminder function

oxygenanalysisTechnical parameters of the instrument:

Gas detection:oxygenO2 Optional: Simultaneous detection16 types, up to 18 types of gas and temperature and humidity measurements, depending on the sensor and on-site environment

Detection range:0~5%, 30% Vol,0~1000, 5000, 1000050000ppm optional, other ranges can be customized

Resolution:0.01%Vol or 0.001% Vol (099.999% Vol, 1ppm optional

Detection principle:Electrochemical and fluorescence principles are optionalDepending on the measurement range, on-site environment, and user requirements

Sensor lifespan:Industrial 6 yearsFluorescence principle5 years

Anti interference capability:(Industry)Completely offsetting the effects of antioxidant carbon, carbon dioxide, and propane, the interference coefficient of other gases is: hydrogen sulfide 0.01%,

Sulfur dioxide 0.01%, benzene 0.02%, hydrogen 0.02%, nitrogen oxide 0.005%

Detection method:built-inPump suction, traffic800 milliliters per minute

Display mode:3.5-inch 320X240 resolution large screen clear color screendisplay

Detection accuracy:≤±1%(F.S)More precise and customizable

line sexually Degree:≤±1%

weight repeated Sex:≤±1%

Uncertainty:≤±1%

Alarm method:audible and visual alarmVisual alarm, sound and light+Visual alarm, turn off alarm

Response time:T9010second

Recovery time:10second

Working power supply:DC3.6V

Usage environment:Temperature-40℃~+70℃; Relative humidity ≤0-99%RH

Sample gas temperature:-40℃~+70℃Optional temperature sampling and cooling filter handle or temperature and humidity pretreatment system can detect 1300The concentration of flue gas

Temperature display:-40℃~+120℃Accuracy 0.5

Humidity display:0~100%RHAccuracy 3% RH

Battery capacity:3.6VDC,10000mARechargeable molecular polymer battery, withOvercharge, overdischarge, overvoltage, short circuitProtection function

Communication interface:Infrared, USB, RS232 automatic recognition

Explosion proof type:Intrinsically Safe

Explosion proof mark:Exia II CT4

Protection, etc.:IP66. Rain and water splashes, dust prevention

External dimensions:230×210×120mm(L×H×W)

Weight:2.5Kg

Application scenarios:All occasions requiring gas concentration detection and analysis, including petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment, etc


Conventional gas types and parameters (gas types, ranges, and resolutions not listed can be customized by phone)

The measurement range of the tested gas can be selected with range resolution and response time

Flammable gas (EX)

0-100%LEL

0-100%VOL

0.1%LEL/0.1%VOL

≤10S

Oxygen (O2)

0-30%VOL

0-25%VOL

0.01%VOL

≤10S

Carbon monoxide (CO)

0-1000ppm

0-2000ppm

0.1ppm/1ppm

≤10S

Hydrogen sulfide (H2S)

0-100ppm

0-1000ppm

0.01ppm/0.1ppm

≤10S

Ammonia (NH3)

0-100ppm

0-200ppm

0.01ppm/0.1ppm

≤10S

Chlorine gas (CL2)

0-10ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Hydrogen chloride (HCL)

0-20ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Nitric oxide (NO)

0-100ppm

0-250ppm

0.01ppm/0.1ppm

≤10S

Nitrogen dioxide (NO2)

0-20ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Formaldehyde (CH2O)

0-10ppm

0-50ppm

0.01ppm/0.1ppm

≤10S

Ozone (O3)

0-10ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Carbon dioxide (CO2)

0-2000ppm

0-100%VOL

1ppm/0.01%VOL

≤10S

JG3000 series gas selection table

Gas type and molecular formula

Optional range (range not listed can be customized by phone); The letter 'Chang' indicates the standard range

CO Carbon Monoxide

0-50, 100, 200, 500, 1000 (normal), 2000, 5000ppm

H2S hydrogen sulfide

0-10, 20, 50, 100, (normal), 200, 0-500, 1000, 2000ppm

O2 oxygen

0-5%, 25%, 30% (Regular), 50% VOL

EX may have natural gas

0-100% LEL (normal)

N2 nitrogen gas

0-100%. Vol (often)

NH3 ammonia gas

0-50, 100ppm (normal), 200, 500, 1000, 2000, 5000ppm

CL2 chlorine gas

0-10 (normal), 20, 50, 100, 200, 500 ppm

VOC Total Volatile Organic Gas Detector

0-2、10、50、100、200、1000、2000、6000、10000PPM

H2 hydrogen gas

0-500, 1000 (normal), 2000, 5000, 10000, 20000, 40000 ppm

CH2O formaldehyde

0-10 (normal), 20, 50, 100, 500, 1000ppm

O3 ozone

0-1, 5, 10, 20, 50 (normal), 100, 200, 500, 1000ppm

CO2 carbon dioxide (infrared)

0-1000, 2000 (normal), 5000, 10000, 50000ppm

CO2 carbon dioxide (infrared)

0-10%、20%、50%、100%Vol

NO nitric oxide

0-100, 0-250 (normal), 500, 1000, 2000, 4000ppm

NO2 Nitrogen dioxide

0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm

NOX nitrogen oxides

0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm

SO2, sulfur dioxide

0-10, 20, 100 (normal), 150ppm, 200, 1000, 2000 ppm

ETO epoxyethane

0-10 (normal), 20, 50, 100ppm

Ethylene oxide ETO

0-500、1000ppm

PH3 phosphine

0-10 (normal), 20, 50, 100, 1000, 2000, 3000, 5000ppm

HCL hydrogen chloride

0-10 (normal), 20, 50, 100ppm

HCN hydrogen cyanide

0-10 (normal), 20, 50, 100ppm

COCL2 phosgene

0-1ppm (normal)

CLO2 chlorine dioxide

0-1, 10 (normal), 20, 50ppm

SiH4 silane

0-10, 50ppm (normal)

F2 fluorine gas

0-1 (normal), 10ppm

HF hydrogen fluoride

0-10 (normal), 50ppm

HBr hydrogen bromide

0-10, 50 (normal), 100ppm

B2H6 diborane

0-5, 10, 50ppm (normal)

AsH3 arsine

0-1, 10 (normal), 50ppm

GeH4 Germanane

0-1ppm (normal)

N2H4 hydrazine, hydrazine

0-1ppm (normal)

THT tetrahydrothiophene

0-100ppm, 0-50mg/m3 (normal), 0-100mg/m3

Br2 bromine gas

0-5, 10 (normal), 50ppm

C2H2 acetylene

0-100ppm (normal)

CS2 carbon disulfide

0-100% LEL, 50ppm (normal)

C3H3N acrylonitrile

0-10, 20 (normal), 50, 100ppm

CH3COOH ethyl acetate

0-10、20p、 50, 100 (normal), 500, 1000ppm

C2H4 ethylene

0-10 (normal), 20, 50, 100, 500, 1000ppm

CH3OH methanol

0-50, 100 (normal), 500, 1000ppm

C2H5OH ethanol

0-10, 50, 100 (normal), 500, 1000ppm

CH4S Methyl Thiol

0-20 (normal), 50ppm

C2H3Cl vinyl chloride

0-50, 100ppm (usual)

Chloromethane (monochloromethane, dichloromethane, etc.)

0-50、100ppm

C8H8 styrene (electrochemical)

0-50、200、1000、10000ppm

Styrene (PID)

0-100 (normal), 200, 1000, 6000ppm

Total volatile organic compounds (TVOC) PID

0-1,10,50PPM, (High precision, high resolution 0.001PPM)

Total volatile organic compounds (TVOC) PID

0-100 (normal), 2001000, 6000, 10000ppm

Bromomethane (CH3Br) (PID photoionization)

0-100 (normal), 2001000, 10000PPM

Bromomethane (CH3Br) (electrochemical)

0-50100 (normal), 2001000ppm

C6H6 benzene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

C6H6 benzene (PID photoionization)

0-100 (normal), 2001000, 600010000ppm

Toluene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

Toluene (PID photoionization)

0-100 (normal), 200,1000, 6000, 10000ppm

Xylene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

Xylene (PID photoionization principle)

0-100 (normal), 2001000, 600010000ppm

Total volatile organic compounds (TVOC) electrochemistry

0-10,50,100PPM

C6H6 benzene (electrochemical)

0-10,50,100PPM

Toluene (electrochemical)

0-10,50,100PPM

Xylene (electrochemical)

0-10,50,100PPM

The ranges listed in the above table are conventional ranges and are not included in the list. If you need to test, please consult our sales personnel

Jinggong Instrument provides you with comprehensive technical support and after-sales service! Details consultation: WeChat Same Account




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!