MPG-1206Multi parameter water quality online analysis system integration platform, which can directly integrate multiple water quality online analysis parameters into one machine, in large-scale applications(7or10Centralized viewing and management on the touch screen panel display;
This system integrates online water quality analysis, remote data transmission, database, and analysis software
Flexible configuration combinations,The sample and analysis section inside this cabinet combines water turbidity, residual chlorinepHConductivity, dissolved oxygen, temperatureORPTheSSTheTDSBy using standard parameters, it can also be extended to meet the actual needs of different customers6、8、10、12Item or more parameters; The waterway section adopts the company's application research results - a series flow analysis device, which requires very few water samples and has strong real-time performance. When a small water sample flows through multiple sensors, it is sorted according to different technical characteristics and response sequences. When the water sample passes through the flow device, all parameters are captured in real time, and it can also achieve continuous expansion of external large units;
Remote data transmission options with multiple routing options are available, allowing for centralized viewing, situational analysis, and other remote data processing on our company's large data servers using platform analysis software. We can also build our own databases and servers for software development for our clients.
Technical Specifications:
|
System model |
MPG-1206 |
|
|
Measurement configuration |
Turbidity/residual chlorine/pH/conductivity/dissolved oxygen/temperature |
|
|
measurement range |
Residual chlorine/chlorine dioxide |
(0.01-2.00)mg/L; (0.01-20.00)mg/L(ppm) |
|
|
turbidity |
0.001-4000)NTU |
|
|
pH |
0.00-14.00PH differential electrode |
|
|
conductivity |
(0-20000)us/cm |
|
|
dissolved oxygen |
(0.01-20.00)mg/L |
|
|
temperature |
(0.0-99.9) ℃ (Thermal element: NTC10K) |
|
resolution |
residual chlorine |
0.01mg/L |
|
|
turbidity |
0.0001NTU when<10NTU |
|
|
|
>0.001NTU at 10NTU |
|
|
pH |
0.01 |
|
|
conductivity |
0.01μS/cm |
|
|
dissolved oxygen |
0.01mg/L |
|
|
temperature |
0.1℃ |
|
accuracy |
residual chlorine |
Within the 90% confidence interval, not exceeding ± 10% FS |
|
|
turbidity |
± 2.5% FS when<40NTU |
|
|
|
>± 5% FS at 40NTU |
|
|
pH |
0.01pH |
|
|
conductivity |
±1.0% |
|
|
dissolved oxygen |
0.3mg/L |
|
|
temperature |
±0.5℃ |
|
communication interface |
RS485 |
MODBUS RTU Communication Protocol |
|
working power supply |
System power supply voltage |
AC 220V±10% |
|
working environment |
Temperature: (0-50) ℃; Relative humidity: ≤ 85% RH (without condensation) |
|
|
storage environment |
Temperature: (0-60) ℃; Relative humidity: ≤ 85% RH (without condensation) |
|
|
Cabinet dimensions |
1500mm×550mm×450mm (height x width x depth) |
|