Guangzhou Dongyi Automation Technology Co., Ltd
Home>Products>Insert thermal gas flowmeter
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    2nd Floor, Building 3, Jibang Technology Park, No. 8 Jishan New Road Street, Tianhe District, Guangzhou
Contact Now
Insert thermal gas flowmeter
Insert thermal gas flowmeter
Product details

product overview


Thermal gas flowmeter is an instrument that uses the principle of thermal conduction to measure fluid flow rate. The instrument uses the constant temperature difference method to accurately measure gas mass flow rate. Thermal gas mass flow meters have the advantages of small volume, high degree of digitization, easy installation, and accurate measurement.


Product Features


1Proprietary traffic data model algorithm; Fuzzy theory control algorithm for temperature and humidity;
2
High performance intelligent microprocessors and analog-to-digital/digital to analog conversion chips;
3
Large caliber, low flow rate, negligible pressure loss, wide range ratio10001, can be expanded according to user requirements;
4
Directly measure mass flow without temperature and pressure compensation;
5
Low flow velocity measurement is very sensitive;
6
Convenient design and selection, easy installation and use;
7
Suitable for measuring the flow rate of various single or mixed gases.
8
Adopting highly stable patented technology platinumRTDsensor
9
Adopting proprietary technology "balanced structure packaging",Self compensation of medium temperature
10
Proprietary algorithm,Can achieve high linearity, high repeatability, and high precision
11
It can achieve measurement of large pipe diameter and small flow rate, and the minimum flow rate can be measured as low as zero,resolution0.001m/s
12
No movable parts, vibration impact can be ignored
13
The requirements for straight pipe sections are not high1-2D
14
It is independent of the temperature and pressure of the medium
15
Exclusive high-temperature algorithm, medium temperature can reach+510℃,
16
Input traffic signals12Point dynamic correction, built-in10Point correction
17
Online dynamic correction of current/Voltage Output

Product Application


1Public works---Monitoring of electricity, gas, and water treatment
Gas in pipelines; Universal system; Biogas; Gas; natural gas; liquid gas; Preheating air for boiler
2Oil and gas industry

Energy exchange; Gas recovery from filling wells; Gas metering; Gas quality analysis; Leakage test; Natural gas measurement; Torch gas monitoring
3The power industry

Gas measurement during gas distribution in fuel systems; Measurement of various gases in boilers and auxiliary systems; Gas measurement in gas furnaces; Hydrogen measurement; Measurement of primary and secondary air in power plant blast furnaces
4Chemical industry

Smoke circulation monitoring; Gas flow measurement in sampling system; Gas flow measurement of induced draft fan; Measurement of ammonia gas in fertilizer plants; Measurement of various gas flow rates in battery factories
5Metallurgical industry

Gas filling measurement in steel plants; Measurement of blast furnace gas in ironworks; Measurement of coke oven gas in coking plants; Measurement and control of heating furnace gas (blast furnace gas, coking gas, natural gas, etc.) in steel rolling mills; Control of gases such as hydrogen, oxygen, and nitrogen in heat treatment quenching furnaces, etc
6Pulp and paper industry

Gas measurement in wastewater treatment system; Smoke flow monitoring; Boiler recycling secondary/Three levels of air; Boiler gas and air supply measurement
7Food and pharmaceutical industry

The addition of fresh air during processing operations; CO2 treatment in breweries; The flow rate of hot air in the bottle sterilizer; Measurement of gas flow rate during thermal oxidation process; Ventilation system; Boiler inlet, exhaust gas, process control
8environment protection

Gas measurement during biogas utilization process; Measurement of chlorine gas during chlorine treatment process; Gas measurement in aeration tanks during sewage treatment process; Exhaust monitoring of chimney and flueSO2andNOXThe displacement
9Other industries

Factory compressed air measurement; Coal powder combustion process/Gas ratio control fuel; Control of Hot Gas Flow from Vertical Grinding Mill in Cement Industry


Product parameters


1Measurement range:0.5100Nm/s20℃,101.33KPa
2Accuracy:±1.5%The reading is ±1.5%full scale

3Range ratio: Typically1001(depending on the range of calibrated flow)

4Range of pipe diameter: 15mm6000mm

5Scope of application:Suitable for various types of single or mixed gases. Containing dust, sand, moisture, and various corrosive gases. (Excluding acetylene gas)

6Environmental temperature range: - forty℃~+85℃; Humidity less than90%RH

7Temperature range of the medium: - forty℃~+100℃;-40℃~+200℃;-40℃~+450℃;-40℃~+510

8Sensor diameter: ф3、 ф2.5

9Insertion sensor probe diameter: ф19(Standard) ф16、 ф12

10Sensor material:316Stainless steel, Hastelloy, titanium

11Material of probe rod (protective cover):316Stainless steel (standard), Hastelloy alloy

12Bidirectional measurement of medium flow rate

13Analog output: Flow rate:4-20mADC,Temperature:4-20mADC,Maximum Load: one thousandΩ

14Accumulated pulse output

15Type in12Nonlinear correction of segments, built-in10Nonlinear correction of segments

16Communication: Serial port outputRS232/RS485

17Power supply:24VDC/600mA220VAC/2W

18Alarm:12Circuit relay output5A/220V5A/30VDCEnter settings

19Large screenLCDDisplay: 7-digit instantaneous flow, 8-digit cumulative flow

20Process pressure: 1.6Mpa(Maximum)20MPa

21Installation process form: Plug in type (card sleeve, card sleeve+ball valve, flange connection) suitable forDN80The above pipeline installation, pipeline type (flange, threaded connection) is suitable forDN15The above pipeline installation.

22Explosion proof grade: intrinsic safety type(iaCT5)Explosion proof type(ExdCT4

23Protection level:IP65

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!