Inductive probe, probe
Inductive probe, probe
Product details
Pen sensor/high-precision inductive probe Electronic probe: SYLVAC,P2,P5,P10,P25,P50

High precision inductance probe: SYLVAC,P2,P5,* The image shows the application of the sensor

*B=Roller bearing; V=vacuum lift; L=Right angle type; S=The measuring head is equipped with a rubber protective cover. Unless otherwise specified, it refers to friction bearings P10, P25, P50 with inductive probes or sensors

Technical parameters:
model measuring range Pre itinerary maximum error Correction error Repeatability Standard force measurement Waterproof standard
P2BL 2mm 0.25mm 1.5µm 0.5µm 0.2µm 0.60-0.75N
P2B
P2BV
P2BVL
P5 5mm 0.7mm 1.6µm 0.6µm 0.2µm 0.60-1.20N IP64
P5BL 0.50-0.90N
P5V 0.60-1.20N
P5B 0.50-0.90N
P5BV 0.50-0.90N
P5L 0.60-1.20N
P5BVL 0.50-0.90N
P5LV 0.60-1.20N
P10 10 mm 0.5 mm 1.6 µm 0.6µm 0.2µm 0.60-0.80N IP40
P10S 0.70-1.25N IP50
P10L 0.60-0.80N IP40
P10LS 0.70-1.25N IP50
P25 25 mm 0.8 mm 1.9µm 0.8µm 0.2µm 0.60-1.00N IP40
P25S 0.70-1.40N IP50
P50 50 mm 1 mm 3.9µm 1.5µm 0.4µm 0.50-1.10N IP40

Technical parameters:
model measuring range Pre itinerary maximum error Correction error Repeatability Standard force measurement Waterproof standard
P2BL 2mm 0.25mm 1.5µm 0.5µm 0.2µm 0.60-0.75N
P2B
P2BV
P2BVL
P5 5mm 0.7mm 1.6µm 0.6µm 0.2µm 0.60-1.20N IP64
P5BL 0.50-0.90N
P5V 0.60-1.20N
P5B 0.50-0.90N
P5BV 0.50-0.90N
P5L 0.60-1.20N
P5BVL 0.50-0.90N
P5LV 0.60-1.20N
P10 10 mm 0.5 mm 1.6 µm 0.6µm 0.2µm 0.60-0.80N IP40
P10S 0.70-1.25N IP50
P10L 0.60-0.80N IP40
P10LS 0.70-1.25N IP50
P25 25 mm 0.8 mm 1.9µm 0.8µm 0.2µm 0.60-1.00N IP40
P25S 0.70-1.40N IP50
P50 50 mm 1 mm 3.9µm 1.5µm 0.4µm 0.50-1.10N IP40
Technical parameters:
model measuring range Pre itinerary maximum error Correction error Repeatability Standard force measurement Waterproof standard
P2BL 2mm 0.25mm 1.5µm 0.5µm 0.2µm 0.60-0.75N
P2B
P2BV
P2BVL
P5 5mm 0.7mm 1.6µm 0.6µm 0.2µm 0.60-1.20N IP64
P5BL 0.50-0.90N
P5V 0.60-1.20N
P5B 0.50-0.90N
P5BV 0.50-0.90N
P5L 0.60-1.20N
P5BVL 0.50-0.90N
P5LV 0.60-1.20N
P10 10 mm 0.5 mm 1.6 µm 0.6µm 0.2µm 0.60-0.80N IP40
P10S 0.70-1.25N IP50
P10L 0.60-0.80N IP40
P10LS 0.70-1.25N IP50
P25 25 mm 0.8 mm 1.9µm 0.8µm 0.2µm 0.60-1.00N IP40
P25S 0.70-1.40N IP50
P50 50 mm 1 mm 3.9µm 1.5µm 0.4µm 0.50-1.10N IP40

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!