The detection tube of the transmitter is equipped with a set of reed switches and precision resistors. When the magnetic float outside the tube changes with the liquid level, the reed switches located at the liquid level inside the detection tube are sequentially connected to change the resistance value of the transmitter. The conversion circuit module inside the junction box converts its resistance value into current output.
Measurement range: 300-8000mm
Accuracy: ± 1.5% FS (measurement range greater than 1000mm)
Power supply: 24VDC (15-35V) 24V power supply can be provided by our company's display instrument
Power consumption: ≤ 720mW
Output signal: 4-20mA two-wire system
Working pressure: 1.6 MPa, 2.5 MPa
Working temperature: High viscosity type:- 35~120℃
Medium density: 0.5~2.0g/cm3
Medium viscosity: ≤ 0.8Pa s 3Pa s
Explosion proof mark: Explosion proof type: d Ⅱ BT4~T6
Intrinsic safety type: ib Ⅱ CT4 ~ T6
Shell protection: IP65
Connection flange standard: Made according to the HG20593-97 DN100 PN1.0 raised face flange standard of the Ministry of Chemical Industry. Please specify other standards by the user
Electrical interface: 2 M20 * 1.5 internal threads