High throughput grinder
model: XM-GTL500
Brand: Shanghai Jingxin ®
Specification: Unit
Product Description:
Shanghai Jingxin ® The high-throughput tissue grinder (patented product, counterfeit will be prosecuted! ZL2018300207398) is a special, fast, efficient, and multi tube consistent system. It can extract and purify raw DNA, RNA, and proteins from any source, including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.
Technical features:
Compared with other existing sample preparation methods, this grinder has the advantages of wide versatility, high efficiency and flexibility. This system avoids many disadvantages such as laborious, time-consuming, and inefficient traditional methods such as grinding, homogenization, and ultrasonic treatment, and can efficiently, quickly, and stably lyse and purify nucleic acids and proteins of various types of samples.
Grindable samples:
1. Plant tissues: roots, stems, leaves, flowers, fruits, seeds, etc
2. Animal tissues: brain, heart, lungs, stomach, liver, thymus, kidneys, intestines, lymph nodes, muscles, bones, etc
3. Fungi and bacteria: yeast, Escherichia coli, etc
4. Food and drugs: various types of food, pills, etc
5. Volatile samples: coal, oil shale, wax products, etc
6. Plastics and polymers: PE、PS、 Textiles, resins, etc
Operation process:
Product features:
This grinding machine adopts a special vertical up and down integrated vibration mode, which uses high-frequency reciprocating vibration, impact, and shearing of grinding beads (zirconia, steel beads, glass beads, ceramic beads). Quickly achieve the goal. Make the ground samples more sufficient, uniform, repeatable, and free from cross contamination between samples
1. Multiple operations with good results
Efficient and fast work can complete the grinding of 2 × 24, 2 × 48, and 4 × 96 samples within 1 minute. Time and effort saving, with small differences between batches and within batches. The extracted protein has higher specific activity and longer nucleic acid fragments.
2. No cross contamination
The sample tube is in a fully enclosed state during the crushing process, and disposable centrifuge tubes and beads can be used. The samples are kept intact in the tube to avoid cross contamination between samples and external contamination.
3. Easy to operate
3.1 Built in program controller, which can set parameters such as grinding time and rotor vibration frequency;
3.2 Humanized operating interface.
4. Good stability
4.1 Adopting vertical oscillation method for more thorough grinding and better stability;
During the operation of the instrument, the noise level should be less than 50dB and should not interfere with other experiments or instruments.
5. Convenient low-temperature operation
When a low-temperature grinding environment is required, the adapter containing the sample can be immersed in liquid nitrogen and cooled for 1-2 minutes. After removal, it can be quickly fixed on the host to start grinding without the need for further freezing treatment, saving liquid nitrogen.
6. Good repeatability
Set the same procedure for the same organizational sample to achieve the same grinding effect. Short working hours, sample temperature will not rise
Technical parameters:
main parameter |
Parameter Range |
Application areas: |
Organization homogenization, grinding, cell lysis, homogenization, material dispersion, preparation, sample mixing, oscillation |
Sample processing: |
15Capable of processing both throughput and throughput within seconds384A sample, including applicable ones12Position and24Liquid nitrogen freezing adapter |
Compatible sample size: |
384*(0.2-0.5ML) /192*2ML /48*5ML/24*(7-15)ML /4*25ML /2*50ML, various specifications of grinding tubes can be customized at will |
Touch screen display: |
It can be operated conveniently and intuitively, and can also be upgraded to touch screen display operation. |
Storage data: |
Can store ten sets of experimental data, with animal heart, spleen, lungs, kidneys, bones, skin, and hair patterns set according to different experimental samples |
Seismic principle: |
The German innovation Schleifen-1 features an innovative shock-absorbing principle, as well as a special vertical up and down integrated movement method and an innovative grinding bead movement method, ensuring the idealization of sample processing and instantaneous crushing effect. |
Feed size: |
No requirements, adjust according to the adapter |
Discharge particle size: |
~5µm |
Number of grinding platforms(Acceptable number of grinding tanks) |
>2 |
Fastening device with automatic center positioning |
yes |
Homogenization speed and time: |
0—70 HZ/second,working hours:0second-9999Minutes, users can set them themselves; |
Grinding ball diameter: |
0.1-30mm |
Grinding ball material: |
Alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand; |
Acceleration: |
stay2Reaching a high speed within seconds |
Slow down: |
stay2Reaching a lower speed within seconds |
Noise level: |
<55db |
Grinding method: |
Wet grinding, dry grinding, and low-temperature grinding are all acceptable |
Refrigeration: |
Capable of upgrading to ultra-low temperature liquid nitrogen freezer or air cooler for refrigeration |
Adapter material: |
Adapter material: PTFE or alloy steel |
Full protection: |
The fastening device with automatic center positioning is equipped with a safety lock during operation, providing full protection throughout the process |
Grinding kit material: |
Hard and rigid,Polytetrafluoroethylene (PTFE) zirconia |
Instrument size: |
400millimeter*340millimeter*530millimeter |
Instrument weight: |
45kg . |
Basic configuration:
Ø One XM-GTL500 host
Ø 2ml adapter set, 2ml refrigeration adapter set, 2ml refrigerant adapter set (optional)
1000 Ø 5MM grinding beads. 1000 5MM ceramic grinding beads
Ø One set of specialized bead gun (optional)
remarks
*The XM reagent kit can be used to quickly, efficiently, stably, and batch extract DNA/RNA proteins from samples
*1HZ=30 revolutions per second 1HZ=100 RPM
*Conventional adapters can be placed in the refrigerator to provide a cold environment for samples during operation. An adapter with refrigeration can be provided, which can be soaked in liquid nitrogen for more than thirty minutes.
*The noise emission value for the working environment depends on the type of sample and the setting of the grinder. The parameters in the table are in an unloaded state
*Small amounts of samples typically used for DNA and RNA separation can be prepared in disposable centrifuge tubes. An adapter made of polytetrafluoroethylene material can be used to accommodate 5 or 10 disposable sample tubes for cell lysis. In the multi sample tissue grinder, cell tissue is rapidly and effectively fragmented in a very short period of time, thus eliminating the need for additional low-temperature refrigeration
Optional Accessories
Jingxin is equipped with comprehensive DNA, RNA, and protein extraction kits for various samples such as animals, plants, and microorganisms, which can quickly, efficiently, stably, and in bulk extract target components.
Extract objects | Jingxin matching reagent kit | |
Animal organization | DNA | XM-1 |
RNA | XM-2 | |
protein | XM-3 | |
plant tissue | DNA | XM-4 |
RNA | XM-5 | |
protein | XM-6 | |
microorganism | DNA | XM-7 |
RNA | XM-8 | |
protein | XM-9 |