Shanghai Nuobing Freezing Machinery Co., Ltd
Home>Products>High temperature water source heat pump unit at 110 ℃
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18001904189
  • Address
    No. 118 Shantong Road, Jinshan High tech Park, Shanghai
Contact Now
High temperature water source heat pump unit at 110 ℃
High temperature water source heat pump unit at 110 ℃
Product details

Our company specializes in researching and producing screw type high-temperature water source heat pump units, which can reach a maximum temperature of110℃Heating capacity50kwarrive3000kwOptional. Screw type high-temperature water source heat pump unit, using environmentally friendly refrigerantR134aOr specialized high-temperature mixed refrigerant, fully utilizing industrial wastewater, bathing wastewater, geothermal tail water, oilfield reinjection water, urban centralized heating return water, etc. as heat source water, can completely replace coal-fired gas boilers, efficient and energy-saving, and produce75℃The above high-temperature hot water meets the demand for centralized high-temperature heating or industrial process hot water. Compared to room temperature screw water source heat pump units, hot water has a higher temperature and a wider range of applications,NBSGThe screw type high-temperature water source heat pump unit is suitable for heating occasions with radiators at the end, slaughterhouses, chemical electroplating and electronics, metallurgical smelting, food drying, food and tobacco drying, textile printing and dyeing, packaging and printing, cosmetic raw material industries, electronics and other industries that have high-temperature heat sources and require high-temperature hot water.

The main features of our screw type high-temperature water source heat pump unit are as follows:

1、 The overall framework structure is compact and beautiful:

1The unit structure layout is convenient, compact, and simple. The compressor, evaporator, and condenser are arranged in layers above and below, while other refrigeration components are arranged along the periphery of the frame, making it convenient for users to fully grasp the operating status of the unit. This provides effective protection for the evaporator and condenser during transportation, machine room installation, and daily operation, and makes maintenance more convenient. The layout inside the unit has undergone three-dimensional optimization design, with a compact layout and optimized external proportions. It requires less maintenance and repair space, occupies less room space, and significantly saves space.

2、 Compressor description:

1. Adopting a specially designed semi enclosed twin-screw compressor for high-temperature water source heat pump units, with a large capacity and high-efficiency motor, the compression ratio and displacement are higher than those of room temperature heat pump units, ensuring efficient and stable operation of the unit under high-temperature conditions.

2. Adopting high-precision machining of twin-screw rotors, aviation grade bearings are sturdy and wear-resistant, with stable performance, low noise, low vibration, and smooth operation.

3. Oil separator: The compressor is equipped with a three-stage high-efficiency oil separator, and a separator is designed on the pipeline to ensure extremely high oil separation efficiency even at very high exhaust speeds. By improving the oil supply and lubrication method, the exhaust oil content and exhaust superheat are effectively reduced, thereby further improving the oil separation effect.

4. According to the needs, it can be adjusted in stages or continuously: energy control can be achieved through a slide valve, which can increase the cooling capacity10%--100%Stepless adjustment within the range.

3、 Evaporator (optional high-efficiency falling film evaporator) features:

1Adopting a shell and tube asymmetric structure design, where gaseous and liquid refrigerants flow through heat transfer copper tubes with different cross-sectional areas, the refrigerant circulates at the optimal and uniform flow rate regardless of whether it is in liquid or gas state. This not only allows the refrigerant to evaporate fully, but also reduces the circulation resistance of the circuit.

2Compared with symmetrical structures, asymmetric evaporators not only have higher heat transfer efficiency, but also have higher oil return efficiency.

3High heat transfer efficiency vortex shaped internally threaded copper tube increases heat transfer area and refrigerant disturbance, improving heat transfer efficiency.

4The design, manufacturing, and inspection of the evaporator all comply withGB/150Steel Pressure VesselsJB/4750National standards and regulations for pressure vessels such as "Pressure Vessels for Refrigeration Equipment".

4、 Condenser (optional high-efficiency falling film condenser) features:

1. The shell and tube heat exchanger adopts efficient double threaded copper tubes, which improves the heat exchange effect between the shell side refrigerant and the tube side cooling water, and increases the heat exchange efficiency by up to30%about.

2. The condenser adopts a unique intake method to evenly distribute the flow of refrigerant, extend the condensation distance, and achieve the best heat transfer effect. It also increases the subcooling of the unit, thereby effectively improving the cycle efficiency of the unit. 3. The design, manufacturing, and inspection of the condenser all comply withGB/150Steel Pressure VesselsJB/4750National standards and regulations for pressure vessels such as "Pressure Vessels for Refrigeration Equipment".

5、 Control cabinet:

1. The start-up and microcomputer control parts of the high-temperature water source heat pump unit are integrated into the same control cabinet, located at the front of the unit, making it easy for on-site operators to operate in the machine room and between units. All electrical repairs can be carried out at the front of the unit.

2. The electrical control box is made of high-quality steel plate, and its outer surface has been galvanized and powder coated to make it resistant to weather and effectively protect the electrical components of the unit.

3. For the safety of operators, once the host is powered on, operators will not be able to open the isolation board between the control and electrical components to ensure their safety.

6、 Control system:

1Using SiemensPLCThe new control system has a good human-machine interface, excellent control and adjustment functions, strong scalability, monitoring and management capabilities, and extremely strong compatibility. Multiple expansion accessories, adding remote and group control functions.

2Friendly human-machine interface: The operation screen is embedded in the unit for convenient operation and good protection. Fully computer-controlled, achieving unmanned operation. visualLCDThe interface displays data and parameter adjustments in multiple languages and menus. According to Clement's tradition, the press status and parameters have separate intuitive displays, making the operation situation clear at a glance.

3The microcomputer intelligent controller has complete fault protection, alarm, recording and analysis functions, including high and low voltage switch, phase loss, reverse phase, overload, overcurrent, overheating, exhaust temperature, water flow, antifreeze and other protection functions. It also realizes the recording and alarm display of faults

7、 Specialized heating80Hot water above ℃:

The high-temperature water source heat pump unit adopts a single environmentally friendly refrigerant R134AOr specialized high-temperature heat pump refrigerant,Utilize the inflow from the water source side10-45Low grade energy at ℃, produced80High temperature hot water at ℃,Satisfy the heating needs of radiators at the end of buildings, as well as the demand for high-temperature hot water for industrial use. Can directly replace coal-fired and gas-fired boilers, environmentally friendly, efficient and energy-saving.

8、 Electronic expansion valve:

The high-temperature water source heat pump unit adopts internationally renowned brand electronic expansion valves, which have high sensitivity and precise control. The refrigerant flow can be quickly adjusted according to actual working conditions, improving the full load and partial load performance of the high-temperature water source heat pump unit.

9、 Efficient economic device energy-saving and oil cooler technology:

1. The system is equipped with a high-performance economizer, and the application of air replenishment and enthalpy increase technology increases subcooling and improves unit performance.
2.
Specially designed oil cooler uses refrigerant cooling to prevent poor lubrication of the system caused by high oil temperature.

In summary, our company's high stability screw type high-temperature water source heat pump units currently use the most advanced technology, professionally equipped with high-temperature heat pump dedicated compressors, high-efficiency spray falling film condenser evaporators, fast response electronic expansion valves, high-efficiency economizers for energy conservation, high-efficiency oil separation cooling systems, and a complete advanced control system to achieve energy-saving, environmentally friendly, efficient, and stable characteristics. At present, our company's screw type high-temperature water source heat pump unit has been widely praised and recommended by customers. If you need related services for screw type high-temperature water source heat pump units, please feel free to contact our company's relevant service personnel at any time.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!