Vi-CELL MetaFLEXHigh speed cell culture biochemical analyzerThe design is based on rapid and accurate analysis of various biochemical indicators in cell culture media, making it an ideal choice for both large-scale production and small-scale development applications in cell culture.
Instrument features:
- Quick: Get all results in just 35 seconds
- Low sample size: The sample size is 65 μ L
- Reliability: Built in calibration process and independent QC verification ensure the reliability of test results
High speed cell culture biochemical analyzerperformance
Measurement parameters | |||
Type | Parameters | Unit | Scope |
pH | pH | PH unit | 6.3-8.0 |
Gas (culture medium) | pCO2 | mmHg; Torr | 5-250 |
kPa | 0.67-33.3 | ||
pCO2
| mmHg; Torr | 0-800 | |
kPa | 0-107 | ||
Electrolyte | cK+ | mmol/L | 0.5-25 |
meq/L | 0.5-25 | ||
cNa+ | mmol/L | 7-350 | |
meq/L | 7-350 | ||
cCa2+ | mmol/L | 0.1-9.99 | |
meq/L | 0.2-19.98 | ||
mg/dL | 0.4-40.04 | ||
cCl- | mmol/L | 7-350 | |
meq/L | 7-350 | ||
Metabolites | cGlu | mmol/L | 0-60 |
mg/dL | 0-1081 | ||
g/L | 0-10.81 | ||
cLac | mmol/L | 0-31 | |
meq/L | 0-31 | ||
mg/dL | 0-279 | ||
g/L | 0-2.79 |
The range of parameters represents the actual measurement range of the analyzer.
measurement system | |
Sample size (full parameters) | 65 μL |
Measurement time (full parameters) | 35 seconds* |
Cycle time | 60 seconds* |
Test flux | 44 samples per hour* |
Average normal operating time | 23.5 hours/day** |
*There are differences during the startup period
*There are differences during the start-up period; System verification takes 2.5 minutes
Sensor box | |
Service life | 300 times (within 30 days after unsealing) |
Retention period | 4 months |
Storage temperature | 2-8°C / 35-46°F |
Automatic quality control | Yes, it is |
Test box | |
Service life | 300 times (within 30 days after unsealing) |
Retention period | 4 months |
Storage temperature | 2-25°C / 35-77°F |
Quality Assurance
Fully automated quality management system
- Three specialized QC reagents
- Automatic detection and fault correction
- Continuous system analysis and verification
- Air detection
- Automatically lock abnormal parameters
- Customizable QC solutions
Instrument certification
- IQ/OQ
Regulatory compliance
21 CFR Part 11
The Electronic Records and Electronic Signature Guidelines (21 CFR Part 11) issued by the US Food and Drug Administration (FDA) stipulate the requirements for submitting electronic format document materials and the standards for approving electronic signatures. The following main system functions of Vi CELL MetaFLEX help ensure its compliance with the regulations of 21 CFR 11:
- Sample result record: 2000
- Activity record: 5000
- Verification record: 1000
- Password protection ensures data security
- Electronic signature function
- Secure user login
- Level 8 user permissions
- Management Configuration Tool