High precision measurement probe DK805 series
High performance measurement probe with a lifespan of 30 million cyclesDK805 seriesAccuracy 0.001mm; Resolution of 0.1 microns, 0.5 microns; Measure a length of 5mm; The longest cable can reach 22m; Easy to install, sturdy design, suitable for various factory operating environments, resistant to oil, water, dust, and strong shock resistance; Matching products: MG10/MG20/MG30/MG40/LY71/LY72/LT30.
The structure is compact and has a high resolution of 0.1 microns, and the response speed has been further improved:
1. Measurement range: 5mm
2. Accuracy: 1 μ m (high-resolution mode), 1.5 μ m (resolution for universal models)
3. Maximum resolution: 0.1 μ m
4. Maximum reaction speed: 80 meters/minute (resolution 0.1 micrometers) 250 meters/minute (resolution 0.5 micrometers)
5. Built in reference points
6. Excellent water and oil resistance.
7. Use flex resistant flexible cables.
8. Suitable for various factory operating environments.
9. Designed to be sturdy and suitable for harsh environments.
10. The air pressure assist device can vertically move the rotating shaft, easy to install, and flange type probe gauges can be selected
model |
High resolution models |
General purpose resolution models |
||
DK805SAR |
DK805SBR |
DK805SAR5 |
DK805SBR5 |
|
DK805SALR |
DK805SBLR |
DK805SALR5 |
DK805SBLR5 |
|
DK805SAFR |
DK805SBFR |
DK805SAFR5 |
DK805SBFR5 |
|
DK805SAFLR |
DK805SBFLR |
DK805SAFLR5 |
DK805SBFLR5 |
|
output |
A/B reference point signal differential line driver output (compliant with EIA-422) |
|||
resolving power |
0.1μm |
0.5μm |
||
measuring range |
DK805S:5mm |
|||
Accuracy (at 20 ℃) |
1μm p-p |
1.5μm p-p |
||
Measurement force |
DK805S downward: 0.45 ± 0.25N
Horizontal direction: 0.40 ± 0.25N
Up: 0.35 ± 0.25N
|
|||
Reference point |
One location (1mm position in axial motion) |
|||
Maximum response speed |
80m/min |
42m/min |
250m/min |
100m/min |
Seismic resistance (20 to 2000Hz) |
100 m/s2 |
|||
Anti impact (11ms) |
1000 m/s2 |
|||
Protective structure * 1 |
SAR/SBR:IP66,SALR/SBLR:IP64(IP67*2) |
|||
Homework temperature |
0 ° C to 50 ° C |
|||
Storage temperature |
-20 degrees Celsius to 60 degrees Celsius |
|||
supply voltage |
DC+5V±5% |
|||
Power consumption |
1W |
|||
Cable length |
2.5m |
|||
Main pole diameter |
Ø80-0.009mm |
|||
weight*3 |
About 30g |
|||
probe |
Equipped with carbide spherical tip (DZ-123) mounting screw M2.5 |
Equipped with steel ball tip and M2.5 mounting screw |
||
parts |
Comes with wrench, user manual, supplementary instructions+ P M4 * 5 screws (2), hose elbow (limited to SAL and SBL types only) |
|||
Output cable length (can be connected to electronic devices) |
Maximum length of 22m |
|||
service life*4 |
At least 30 million times without impact |

Magnescale (formerly SONY) related products
Grating ruler|Magnetic scale
Scale SR127
SR128(GB-A)
SR138(GB-ER)
SL130/SL110
SL331/PL60
SL700/SL710/SL720
SR74/SR75
SR77
SR84/SR85
SR87
PL20C
PL25-3
PL81/PL82
PL60-3
PL101
Digital Gauge
DG10B/DG10N/DG10P
DG25B/DG25P/DG25S
DG50B/DG50P
DG100B/DG100P/DG100N
DG110B/DZ531/DZ581
DG155BP/DG155P/DG205BP/DG205P
DG805/DG810
DK830S
DK110NLR5
DK155/DK205
DK50/DK100
DK10/DK25
DK802A/DK802B
DK805A/DK805B
DK812A/DK812B
DT12N/DT12P
DT32N/DT32P,DT32NV/DT32PV
DT512N/DT512P
DL310B/DL330B
DE12BR/DE30BR
U60B-F
U30B-F
U12B-F
Digital Display Control Unit Displays
LG20
LT10A
LT11A
LT20A
LT30
LH70
LH71
LH72
LY71
LY72
Signal processing unit Detector
MG10/MG20/MG30
MG40/MG41/MG42/MG43
MT12/MT13/MT14
MJ100/MJ110
MJ620
MJ820/MJ821
MJ830/MJ831
Roll detection system
MD20B
MD50-2N/MD50-4N
MSS-976R
HA-705LK
MK3
Related Accessories
SET-B3/SET-K2
SET-P15
SET-P16
DZ/LZ/SZ/CE
PH-100/PH-500
PG-104