Handheld alcohol concentration meterapplication
-
Automatic alcohol concentration ratio in biopharmaceutical industry
-
Continuous monitoring of processes such as organic industrial alcohol, ammonia water, ethanol, etc
-
Daily moisture analysis in the laboratory
-
Monitoring of slurry and slurry concentration during mining process
-
Monitoring and analysis of moisture content in food industry slurries and emulsions
Handheld alcohol concentration meter
feature
-
The measurement range is large and can be applied to 0 Range from 1 to 100%
-
Widely applicable and suitable for testing the concentration of polar to non-polar substances
-
Fast response speed, signal response time<5s,
-
The detection structure is easy to adjust
-
Double temperature compensation is applied to the instrument for higher accuracy.
-
Durable and sturdy, not prone to scaling, adhesion, or blockage
-
The material compatibility selectivity is large, and the test value can be seen in 2-5 seconds
-
Pollution caused by volatile gases during distillation
-
No additional fees for consumables
-
Low energy consumption; DC12V charger; 9V rechargeable battery
/Alcohol concentration meter
Technical Specifications
| Measurement principle | The principle of microwave energy attenuation caused by absorption when passing through matter |
| Measurement object | Organic compounds such as alcohol, ammonia water, mineral slurry, emulsion, etc |
| resolution | 0.1% |
| Measurement range | 0.1%~100% ; Ammonia water: reaching saturation level |
| indication error | ±0.5% |
| stability | Zero drift less than 0.1% within 24 hours |
| Measurement time | 2s. Professional regulations require taking the average, and the function of recording data and then averaging can be used to meet the requirements |
| repetitiveness | Less than 2% within 24 hours (refer to the repeatability calculation formula) |
| monitor | 16x2 LCD liquid crystal display |
| Instrument operating temperature (optional) | -20℃ - 55℃ -10℃ -60℃ 0℃ -80℃ |
| Moisture content scale value | 0.01% |
| work pressure | Less than 0.6MPa |
| power supply | 12VDC or 24VDC |
| signal transmission | Standard (4-20) mA |
| Communication transmission | RS232 serial port or RS485 |
| According to the installation method | Customization upon customer request (flange, chuck, pipeline) |
| insertion depth | 100 millimeters (standard); customizable |
| Application requirements | The mixing of materials must be uniform* |
| box dimensions | Room temperature sensor D38x300mm, high temperature sensor D38x800mm, handheld host: 204x100x36mm |
| packing dimensions | 415x335x120mm at room temperature, 1000x260x110mm |
| Total weight | 4.0kg (room temperature) -6kg (high temperature)
|