Beijing Jingcheng Huatai Instrument Co., Ltd
Home>Products>Handheld ATP fluorescence detector is selling well
Handheld ATP fluorescence detector is selling well
Brief description: The handheld ATP fluorescence detector is popular and uses biochemical reaction methods to detect ATP content. When in use, collect
Product details

Handheld ATP fluorescence detector is selling well

Handheld ATP fluorescence detector is selling wellScope of use:

Suitable for rapid detection of microorganisms in food and drinking water, rapid detection of cleanliness of tableware, rapid detection of disinfection results of food processing equipment, workbenches, catering utensils, etc., and real-time evaluation of medical environment work platforms,Enforcement screening by law enforcement departments (cleanliness control of kitchen and dining table operating tools, evaluation of tableware disinfection, hygiene supervision by quality control departments, rapid testing of catering cleanliness for large-scale commercial events such as the Olympics).

Technical parameters:

1Large screen LCD display

2Detection accuracy:4×10-18mol/ATP

3Scope of testing:0 to 9999 RLUs

4Testing time:15second

5Detection limit:1.4cfu/ml

6Operating temperature range:5℃ to40

7Operating humidity range:2085%

8ATPrate of recovery:90-110%

9Detection mode:RLUE. coli screening

1050A userIDsetting

11Number of adjustable result limits:250individual

12Result expressionAccording to:RLUThe value is calculated using a preset formula and displayed as a level

132000Memory Storage

14Automatically judge as qualified

15Automatically calculate the pass rate

16Built in self calibrating light source

17Turn on the device30Second self check

18Equipped withRS232interface(be equipped withUSBinterface), the results can be uploaded toPC

19Instrument size(W×H×D):190mm×88mm×36mm

20Using rechargeable lithium batteries,Equipped with solar charger and car power supply

21Standby state(20℃):6Month

22Chinese operation manual

23Stable liquid luciferase

24Wet integrated collection swab

Random configuration: Fluorescence detector (handheld) host, instrument package, hanging rope, battery, PC data cable, data analysis software, Chinese operation manual

The ATP fluorescence detector uses biochemical reaction method for detectionATPContent. When in use, use pre wettedATPSwab collection of specimens,ATPThe swab is soaked in buffer solution, which helps to extract biological substances from dry or wet surfaces(ATP). The swab contains a reagent that can lyse the cell membrane, which can separate the cellsATP is released and reacts with specific enzymes contained in the reagent to produce light. The luminescence value is then detected using a fluorescence lux meter, and the number of microorganisms is proportional to the luminescence value.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!