The HYD-3000 intelligent electromagnetic flowmeter is suitable for measuring the volumetric flow rate of conductive liquids flowing in closed pipeline
Product details

The HYD-3000 intelligent electromagnetic flowmeter is suitable for measuring conductive liquids flowing in closed pipelinesThe volumetric flow rate of the body has LCD display, pulse output, and 4-20mA output. It is widely usedMeasurement and control systems in fields such as water treatment, chemical engineering, papermaking, pharmaceuticals, metallurgy, and urban construction.

Main features:

 Flow direction:

straight,reverse side,Net traffic

Range ratio: 150: 1

Repetitive error: ± 0.1% of the measured value

Accuracy level:Pipeline type: 0.5level,1.0level

Temperature of the tested medium:

Ordinary rubber lining:- 20~+60℃

High temperature rubber lining:- 20~+90

Polytetrafluoroethylene lining:- 30~+100

High temperature PTFE lining:- 40~+180

Rated working pressure:

Pipeline type: DN10~DN80:≤ 1.6Mpa DN100~DN250: ≤ 1.0Mpa

DN300~DN1200:≤ 0.6MpaHigh voltage can be customized

Flow measurement range:The flow measurement range and convective velocity range are 0.1~15m/s

Conductivity range:

The conductivity of the measured fluid is ≥ 5 μ s/cm

Most media composed of water have a conductivity of 200~800μs/cmElectromagnetic flow meters can be selected within the range

Current output:

Load resistance: 0~10mAAt 0-1.5K Ω

       4~20mAAt 0~750 Ω

Digital frequency output:The upper limit of output frequency can be within 1~5000HZInternally set, transistor with photoelectric isolation has an open collector and bidirectional output. When the external power supply is ≤ 35v and conducting, the maximum collector current is 250mA

Communication signal output: RS-232, RS-485, Hart, Modbus (RTU format) optional, interface with lightning protection function

Electrode material: Molybdenum containing stainless steel, titanium (Ti)),Tantalum (Ta), Hastelloy (H), Platinum (Pt) or other special electrode materials

power supplyExchange AC85~265V,45~63HZ harmonic<5% DC 16-36V

Length of straight pipe sectionPipeline type upstream ≥ 5DNDownstream ≥ 2DN

Connection methodThe flowmeter and piping are connected by flanges

ambient temperature:- twenty-five~+60℃

relative humidity: 5%~95%

Total power consumption:< 20W