HI9146 Hana portable dissolved oxygen meterSuitable for the determination of dissolved oxygen in different water quality and exhaust gases in various industries, it has an automatic endpoint mode. After selecting this option, once stable measurement results are obtained, the reading will be automatically locked on the LCD display screen. It has a backlit display screen that can easily check the reading in low light conditions. The polarographic dissolved oxygen electrode has a built-in temperature sensor that provides automatic temperature compensation and Good Laboratory Practice (GLP) query function.
Two measurement modes
Provide dissolved oxygen (DO) readings displayed in mg/L (ppm) or saturation percentage (%), with the option to automatically compensate for altitude (max 4000 m) and salinity (max 40 g/L) during measurement. The polarographic dissolved oxygen electrode is equipped with a built-in temperature sensor for automatic temperature compensation, with a temperature compensation range of 0.0 to 50.0 ° C (32.0 to 122.0 ° F)
Automatic calibration
Single point or two-point calibration automatic calibration, zero point or air automatic 100% (8.26mg/L) calibration. In order to perform accurate calibration, it is recommended to wait for at least 15 minutes after replacing the dissolved oxygen film and dissolved oxygen filling solution before calibration to ensure that the dissolved oxygen electrode is in the best state.
Height and salinity compensation
When measuring dissolved oxygen below sea level, the solubility of oxygen increases; When measuring dissolved oxygen above sea level, the solubility of oxygen decreases. The solubility of oxygen in water is also influenced by the salt content in the water. Users can modify these values for quick and convenient height and salinity compensation.
GLPquery
The Good Laboratory Practice (GLP) query function allows for the retrieval of calibration data at any time, including date, time, standards used, as well as temperature, altitude, and salinity values.
dissolved oxygenDO |
range |
Dissolved oxygen DO: 0.00 to 45.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 300.0% |
resolution |
Dissolved oxygen: 0.01 mg/L (ppm), saturated dissolved oxygen: 0.1% |
|
accuracy |
@25 ° C/77 ° F: 1.5% F.S. or one word, whichever is greater |
|
calibration |
Single point or two-point calibration automatic calibration, zero point or air automatic 100% (8.26mg/L) calibration |
|
temperature |
range |
0.0 to 50.0 ° C, 32.0 to 122.0 ° F |
Resolution/accuracy |
Resolution: 0.1 ° C, 0.1 ° F; Accuracy: ± 0.2 ° C, ± 0.4 ° F (ignoring temperature probe) |
|
Compensation indicators |
temperature compensation |
Automatic compensation range 0.0 to 50.0 ° C, 32.0 to 122.0 ° F |
Salinity compensation |
Manual compensation range 0 to 80 g/L (resolution: 1 g/L) |
|
Height compensation |
Manual compensation range 0 to 4000 meters (resolution: 100 meters) |
|
Other indicators |
Standard electrode configuration |
HI76407F built-in temperature sensor, polarographic dissolved oxygen electrode and electrode sheath, specifications: 4 meters or 10 meters |
Power source |
1.5VAAA × 3 high-quality battery |
|
application environment |
0 to 50 °C(32 to 122°F ); RH-max95% (non condensing) |
|
Dimension |
Host size: 185 x 72 x 36 mm (7.3 x 2.8 x 1.4 "), Host weight: 300 g (10.6 oz.) |
HI9146 host Large screen background light LCD, operation guide display, battery level icon, prompt for timely battery replacement, accurate and reliable measurement, automatic compensation for height, salinity and temperature, automatic calibration function in the air, measurement results displayed in ppm (ml/L) or%. |
|
HI7040L customized dissolved oxygen zero (0%) standard solution Standard value: 0%, it is a dual combination zero oxygen solution suitable for calibration of polarographic and electrochemical dissolved oxygen sensors. It uses high-purity chemical reagents and high-quality deionized water, and has been rigorously certified with various measuring tools and containers. It is carefully prepared in a constant temperature and humidity environment that meets the requirements and can be traced back to NIST standard reference materials (SRM). |
|
HI7041 customized dissolved oxygen filling solution Tailored filling solution for polarographic dissolved oxygen electrode design; Specification: 30mL × 4, 230mL, 500mL HI7041 filling solution is customized for Hanna's polarographic dissolved oxygen electrode development. Using the correct dissolved oxygen electrode filling solution is crucial for the performance of the dissolved oxygen electrode; The polarographic sensor technology is based on the Ross and Clark polarographic measurement methods; The dissolved oxygen electrode consists of a platinum electrode and a solid silver electrode. Hana's high-quality potassium chloride solution with unique configuration is used in conjunction with PTFE (polytetrafluoroethylene) dissolved oxygen membrane and polarographic dissolved oxygen electrode; Using polarographic techniques, an external voltage is applied to the platinum cathode, silver anode, electrolyte solution, and gas permeable membrane to establish a current proportional to the oxygen concentration in the solution.
|
|
HI76407A/P, HI76407V/P custom PTFE dissolved oxygen film The dissolved oxygen membrane separates the cathode (platinum material) and anode (silver material) of the dissolved oxygen electrode from the sample to be tested. Oxygen diffuses through the dissolved oxygen membrane and interacts with the polarographic system of the dissolved oxygen electrode to generate a current proportional to the oxygen concentration; When the dissolved oxygen membrane is not in use, the shelf life of the standard storage conditions is two years. After installation and use, it is recommended that users replace it every 6 months in a regular measurement environment.
|
HI9146-04
Host, HI76407F-04 with built-in electrode protection tube and temperature sensor polarographic dissolved oxygen electrode, 4 meters long, HI76407A/P customized dissolved oxygen film, quantity: 2, HI7041S dissolved oxygen filling solution, specification: 30mL, Chinese and English user manual, HI721016 customized instrument carrying case.
HI9146-10
Host, HI76407F-10 with built-in electrode protection tube and temperature sensor polarographic dissolved oxygen electrode, 10 meter long, HI76407A/P customized dissolved oxygen film, quantity: 2, HI7041S dissolved oxygen filling solution, specification: 30mL, Chinese and English user manual, HI721016 customized instrument carrying case.
【TipsTo ensureHI9146 Hana portable dissolved oxygen meterFor convenient measurement or to ensure the stability of measurement data, it is recommended to choose HI181 with electrode holder type magnetic stirrer or HI190M magnetic stirrer. At the same time, Shanghai Jingcan Precision Machinery Co., Ltd. also sells portable Hash from the United StatesHQ30D dissolved oxygen analyzerOnline detection in ItalyMagnetic OD7685Welcome to inquire!