1、 Overview

HG7500Multi functional precisionCalibration instrumentIt is a multifunctional precision display with multi range, wide range, high-precision seven and a half bit output and displayCalibration instrumentThis instrument can output high-precision DC voltage/Current, AC voltage/Current, DC power, and AC power with power factor control, with functions such as resistance simulation, capacitance simulation, and DC voltage and current measurement, suitable for calibration or verificationCalibration devices such as voltmeters, ammeters, power meters, power factor meters, phase meters, frequency meters, multimeters, multimeters, and various power measurement transmitters below level 0.05 can also be used as standard sources. This instrument fully complies withJJG 124-2005 Verification Regulations for Ammeters, Voltmeters, Power Meters, and Resistance MetersJJF 1587-2016Calibration Specification for Digital MultimetersJJF 1284-2011The relevant requirements of the "Calibration Specification for AC/DC Meter Calibration Instruments" can be widely applied to quality inspection, measurement, teaching and research, and instrument maintenance work in industrial and mining enterprises, aerospace, military, research institutes, railways, power, military, schools and other units.

2、 Main functions and features

stem or root of plantsinstrumentVerifiableThe instruments are as follows: indicating instrumentsAC voltmeter,exchangeAmmeter, single-phaseexchangepower meterDC voltmeterdirect-currentAmmeterdirect-currentpower meter, resistance meterCapacitive meter, clamp meter*Wait.

2.1AC/DC voltage output1000Vmaximum1100 Velectric currentoutput100Amaximum110A.Communication frequency range:45Hz1kHz.

2.2Simulated resistance range:0200;Analog capacitor output range:0.1nF200uF;Continuing Adjust.

2.3 Transmittermeasuring range0±12V; 0± 24mA.

2.4 It can accurately output DC power, AC active power, apparent power, and power factor.

2.5Strong load capacity, ensuring stable and accurate measurement values under full load conditions, and can cover the calibration of analog meters.

2.6Output hasFixed point output, potentiometer adjustment, rotary encoder, step ratioVarious methods of adjusting values.

2.7Equipped with a large-sized LCD touch color screen, the measurement value display is intuitive and the operation is very convenient.

2.8 *Optional25T/50TThe coil can generate a maximum of2000AEquivalent current for calibrating AC/DC clamp meters.

2.9The output has comprehensive software and hardware protection functions, improving the long-term reliability of the device.

3、 Main technical indicators

3.1 Technical indicators of DC voltage20℃±2℃):

range

adjust

fineness

accuracy

± (reading value%+full-scale%)

ripple wave

coefficient

Load capacity

RATING

Maximum value

75mV*

5ppm

0.006%RD+0.004%RG

<0.05%

10 mA

100 mA

300mV

20 mA

1V

20 mA

3V

0.003%RD+0.002%RG

20 mA

10V

20 mA

30V

20 mA

100V

5 mA

300V

0.006%RD+0.004%RG

5 mA

1000V

5 mA

30 mA

3.2 Technical indicators of DC current20℃±2℃):

range

Regulating fineness

accuracy

± (reading value%+full-scale%)

ripple wave

coefficient

Load capacity

30uA

5ppm

0.006%RD+0.004%RG

<0.2%

10V

300uA

1mA

3mA

0.003%RD+0.002%RG

10mA

30mA

300mA

2A

10A

0.006%RD+0.004%RG

3V

25A

30A

50A

2V

60A

0.02%RD+0.01%RG

100A

3.3 Technical indicators of AC voltage20℃±2℃):

range

load

capacity

adjust

fineness

accuracy

± (reading value%+full-scale%)

degree of distortion

45-200Hz

>200Hz

100 mV

50 mA

50ppm

0.03%RD+0.02%RG

02%

300 mV

1 V

0.01%RD+0.02%RG

0.03%RD+0.02%RG

3V

10 V

30 V

100 V

300 V

20 mA

1000 V

10mA

0.03%RD+0.02%RG

3.4 Technical indicators of AC current20℃±2℃):

range

load

capacity

adjust

fineness

accuracy

± (reading value%+full-scale%)

degree of distortion

45-1000Hz

0.3 mA

5V

50ppm

0.12%RD+0.08%RG

02%

1 mA

3 mA

0.06%RD+0.04%RG

10 mA

30 mA

100 mA

10V

0.03%RD+0.02%RG

200 mA

0.5 A

1 A

2.5 A

5 A

10 A

4V

25 A

30 A

50A

60A

3V

100A

3.5 Technical indicators of power, power factor, phase, and frequency20℃±2℃):

project

range

accuracy

AC Power

Continuous adjustable from 1W to 30kW

When PF=± 0.8 to ± 1 (50Hz), < 0.05%

When PF=± 0.8~± 0.5 (50Hz), < 0.1%

DC power

Continuous adjustable from 1W to 30kW

0.01%

Power factor

1~-1 continuously adjustable

<0.05%

phase

0~360°

<0.02°

frequency

(Sine wave)

45Hz~200Hz

<0.01%

200Hz~600Hz

<0.03%

600Hz~1000Hz

<0.05%

Scope of AC power assessment:

Voltage:30V, 100V, 300V, 600V

electric current:1A, 2A, 5A, 10A, 20A

Frequency:50Hz

3.6 Analog Resistance Technical Indicators20℃±2℃):

range

accuracy

± (reading value%+full-scale%)

20Ω

0.04%RD+0.02%RG

100Ω

0.03%RD+0.02%RG

2kΩ

20kΩ

200kΩ

2MΩ

20MΩ

0.06%RD+0.04%RG

200MΩ

0.12%RD+0.08%RG

3.7 Simulation capacitor technical indicators:

Capacitance Range

accuracy

± (reading value%+full-scale%)

0.1nF~10nF

0.6%RD+ 0.4%RG

10nF~100nF

0.3%RD+ 0.2%RG

100nF~10uF

0.12%RD+0.08%RG

10uF~200uF

0.3%RD+ 0.2%RG

3.8 DC measurement (transmitter):

range

20mA

2mA

10V

1V

measuring range

-24~+24mA

-2.4~+2.4mA

-12~+12V

-1.2~+1.2V

Input Resistance

100Ω

100Ω

1.25MΩ

1.25MΩ

accuracy

±(0.006%*RD+0.004%*RG)

3.9 Other technical indicators:

weight Quantity:20.5Kg (excluding accessories and packaging boxes)

body Accumulate:520mm×445mm×205mm

Working power supply: AC220V±10%

Working environment: Temperature-20~40°C. Relative humidity ≤ 85%.