VIP member
German Sick LMS511-20190_ Laser Scanner Belt Conveyor Special
German Sick LMS511-20190_ Laser Scanner Belt Conveyor Special
Product details

overview
- Non contact measurement of bulk material volume and mass flow rate
- Laser pulses with high angular resolution ensure extraordinary image accuracy
- The estimation of 5-fold echo pulses ensures the reliability of height measurement
- Non contact conveyor belt monitoring function
- Integrated center of gravity calculator
- Sturdy structure, suitable for harsh environmental conditions
- Integrated built-in heater, suitable for measurement under low temperature conditions
- Compact enclosure with protection level of IP 67
Your benefits
- Maximizing the transportation capacity of conveyor belts
- Prevent conveyor belt slippage and save maintenance costs
- Extend the service life of conveyor belts
- Shorten loading time
- Optimize conveyor belt capacity and improve efficiency
- Simple installation
- Low maintenance cost
- *Minimizing energy consumption for greater energy efficiency
applications
- Volume flow monitoring of raw materials in the food industry
- Monitoring of coal and ore transportation equipment
- Loading device and sedimentation device
- Monitoring dust accumulation in power plants
- Loading control of transportation vehicles such as trucks, ships, and trains
- Volume and mass flow measurement in gravel factories and other fields of the construction industry
Application examples
Conveyor belt monitoring and mill monitoring
Conveyor belt control and coal crusher monitoring
Filling containers for fly ash
Conveyor belt control and crusher monitoring
Conveyor belt control and crusher monitoring in organic waste incineration
Volume measurement during ship loading and unloading
Conveyor belt operation during material handling
Measurement of volumetric and mass flow rates during material handling
Bulk material testing during material handling
Measurement and distribution of coal or sintered material quantity and flow rate on the sintering belt
Level monitoring of waste bins on electric arc furnaces
Conveyor belt control and coal crusher monitoring
Internal monitoring of train carriages
Ship loading, analysis, and volume measurement
Overview of Technical Parameters
measuring principle | Laser time-of-flight technology |
medium | bulk materials |
output signal |
4 mA ... 20 mA Ethernet TCP/IP Switch input and switch output USB auxiliary interface RS-232/RS-422 |
*High conveying speed | ≤ 30 m/s |
Online Data Sheet
LMS511-20190
Bulkscan ® LMS511
flow sensor
LMS511-20190 | Bulkscan ® LMS511
flow sensor
The image may have deviations
ordering information
Type Order Number
LMS511-20190 1059529
Other device specifications and accessories www.sick.com/Bulkscan_LMS511
Detailed technical parameters
Product Features
Infrared light source (905 nm)
Laser level 1, safe for human eyes (IEC 60825-1 (2007-6))
Opening angle 190 °
Scanning frequency 35 Hz
50 Hz
75 Hz
Unlimited bandwidth
The heating device is
Working area of 0.5 meters 20 m
Number of selected Echo protocols 5
performance
Response time 13 ms, 20 ms, 28 ms
Mean filtering 0 s 3,600 s
Accuracy ± 3%, under ideal conditions
≤± 5%, depending on the surface of the material
*Large conveying speed ≤ 30 m/s
interface
help screen ✔
Protocol USB 2.0
Data transmission rate ≤ 500 kBaud
Serial host interface ✔
Protocol RS-232/RS-422
Data transmission rate ≤ 500 kBaud
Ethernet ✔
Protocol TCP/IP
Data transmission rate of 100 Mbit/s
Switch input terminal 2 (+encoder)
2 Fluid Sensors | SICK Online Data Sheet | August 17, 2016 15:21:43
If there are any changes, no further notice will be given!
LMS511-20190 | Bulkscan ® LMS511
flow sensor
Output signal switch device 6
Analog signal provides independent attachment BAM100
Communication interface help interface, 1, USB 2.0, 500 kBaud
Serial host interface, 1, RS-232/RS-422, 500 kBaud
Ethernet, 1, TCP/IP, 100 Mbit/s
Optical signal 5 LEDs (additional 7-segment display)
Mechanical/electronic parameters
Electrical connection 5-pin M12 equipment socket
Scanner/heater power supply voltage 19.2 V 28.8 V
Allow residual ripple ± 5%
Peak current of switch 2 A
Scanner working current ≤ 1.3 A
Power consumption of 22 W+ 55 W heating device (standard)
Shell color gray (RAL 7032)
Protection level of enclosure IP 67 (EN 60529, section 14.2.7)
Protection level III
Weight 3.7 kg
Dimensions 160 mm x 155 mm x 185 mm
The distance between the sensor and the bulk material is ≥ 0.5 meters
Power on delay ≤ 60 seconds
Environmental parameters
Electromagnetic compatibility (EMC) EN 61000-6-2:2005/EN 61000-6-3/A1 2011
Working environment temperature -40 ° C+ 60 °C
Storage temperature range -40 ° C+ 70 °C
Environmental light resistance capacity 70000 lx
classification
ECl@ss five
ECl@ss 5.1.4
ECl@ss six
ECl@ss six point two
ECl@ss seven
ECl@ss eight
ECl@ss eight point one
ECl@ss nine
ETIM 5.0 EC002580
ETIM 6.0 EC002580
UNSPSC 16.
2016-08-17 15:21:43 | Online Data Sheet
If there are any changes, no further notice will be given!
Fluid Sensor | SICK 3
LMS511-20190 | Bulkscan ® LMS511
flow sensor
Dimensional drawing (unit of measurement: mm)
Bulkscan ® LMS511
① 4 threaded holes M8 x 9
② Unobstructed transparent protective cover
③ 4 threaded holes M6 x 8
application
4 Fluid Sensors | SICK Online Data Sheet | August 17, 2016 15:21:43
If there are any changes, no further notice will be given!
LMS511-20190 | Bulkscan ® LMS511
flow sensor
Installation Tips
Bulkscan ® LMS511
90°
Correct positioning
Transport rollers
³ 500 mm
Incorrect positioning
Transport rollers
Recommended accessories
Other device specifications and accessories www.sick.com/Bulkscan_LMS511
Briefly describe the type of order number
Other installation accessories
Mast support tensioning belt (sold by meter) tensioning belt 5306222
Tensioning belt lock Tensioning belt lock 5306221
Clamping bracket and calibration bracket
Mast bracket requires additional installation of bracket (2059271) or fixing kit (2018303) aligned with bracket 2018304
Installation bracket and fixing plate
DFV60 spring arm/mounting arm DFV60 spring arm 2056155
1 piece, installation bracket for direct backward installation onto walls or machines, non adjustable installation kit 1 2015623
1 piece, a mounting bracket for direct installation from the back onto a wall or machine, adjustable along both the longitudinal and transverse axes,
Can only be used in conjunction with fixed component 1 (2015623)
Installation Kit 2 2015624
1 piece, a mounting bracket for direct installation backwards or downwards onto walls, floors or machines, which can be installed along the longitudinal axis and transverse axis
Axis adjustment can only be used in conjunction with fixed components 1 (2015623) and 2 (2015624)
Installation Kit 3 2015625
LMS5xx mounting bracket (for retrofitting when already using 2018303) mounting bracket 2059271
Power supply equipment and power supply cables
2016-08-17 15:21:43 | Online Data Sheet
If there are any changes, no further notice will be given!
Fluid Sensor | SICK 5
LMS511-20190 | Bulkscan ® LMS511
flow sensor
Briefly describe the type of order number
Power supply DC 24 V/4 A power supply 6010362
Power supply DC 24V/10A power supply 6020875
Plug connectors and cables
A head: plug, M12, 4 needles, straight head, D-code
B-head: plug, RJ45, 8 needles, straight head
Cable: Ethernet, suitable for conveyor belts, PUR, shield, 5 m
SSL-2J04-G05ME 6034415
A head: plug, M12, 4 needles, straight head, D-code
B-head: plug, RJ45, 8 needles, straight head
Cable: Ethernet, suitable for conveyor belts, PUR, shield, 10 m
SSL-2J04-G10ME 6030928
A head: plug, M12, 4 needles, straight head, D-code
B-head: plug, RJ45, 8 needles, straight head
Cable: Ethernet, suitable for conveyor belts, PUR, shield, 20 m
SSL-2J04-G20ME 6036158
A head: plug, USB-A, Straight head
B-head: plug, Mini-USB, Straight head
Cable: USB, shield, 3 m
Used to connect the configuration interface with the USB interface of the PC
Connect the cable (insert)
Head plug)
6042517
A head: plug, M12, 12 needles, straight head, A code
B-head: Cable
Cable: Shielded, 5 m
Connect the cable (insert)
Head scattered line
6042732
A head: plug, M12, 12 needles, straight head, A code
B-head: Cable
Cable: Shielded, 10 m
Connect the cable (insert)
Head scattered line
6042733
A head: plug, M12, 12 needles, straight head, A code
B-head: Cable
Cable: Shielded, 20 m
Connect the cable (insert)
Head scattered line
6042734
A head: socket, M12, 12 needles, straight head, A code
B-head: Cable
Cable: Shielded, 5 m
Connect the cable (insert)
Seat scattered line
6042735
A head: socket, M12, 12 needles, straight head, A code
B-head: Cable
Cable: RS-232, RS-422, shield, 10 m
Connect the cable (insert)
Seat scattered line
6042736
A head: socket, M12, 5 needles, straight head, A code
B-head: Cable
Cable: Shielded, 5 m
Connect the cable (insert)
Seat scattered line
6036159
A head: socket, M12, 5 needles, straight head, A code
B-head: Cable
Cable: Shielded, 20 m
Connect the cable (insert)
Seat scattered line
6042564
A head: socket, M12, 5 needles, straight head, A code
B-head: Cable
Cable: Shielded, 10 m
Connect the cable (insert)
Seat scattered line
6042565
A head: socket, M12, 12 needles, straight head, A code
B-head: Cable
Cable: RS-232, RS-422, shield, 20 m
Connect the cable (insert)
Seat scattered line
6042737
Modules and gateways
BAM100 analog module for Bulkscan, manufactured by Beckhoff, operating voltage 24 V DC (-15%)/
+20%), the top cap track is installed on a 35 mm C-shaped track with locking device according to EN 50022, Ethernet
Network TCP/IP interface (RJ45), CoLa communication, 3 x input terminals: 4 mA 20 mA, 4 x output terminals:
4 mA ... 20 mA
BAM100-HE44K 2073296
Lens cleaning cloth
6 Fluid Sensor | SICK Online Data Sheet | August 17, 2016 15:21:43
If there are any changes, no further notice will be given!
LMS511-20190 | Bulkscan ® LMS511
flow sensor
Briefly describe the type of order number
Cleaning cloth, used for cleaning the front panel lens cleaning cloth 4003353
Detection and monitoring tools
Scan and search for receiver Scan Finder LS-80L 6020756 for locating infrared scanners
Programming and configuration tools
Incremental measurement shift encoder, electrical interface: 10... 30 V HTL Push Pull, Wanxiang fixed arm, measuring wheel circumference
Length=300 mm, surface O-ring, connection type: M12 8-pin plug, line count 1024, operating temperature range
- 20 °C ... 100 °C
DFV60E-22EC01024 1060308
Incremental measurement shift encoder, electrical interface: 10... 30 V HTL Push Pull, Wanxiang fixed arm, measuring wheel circumference
Length=300 mm, surface O-ring, connection type: 1.5 m 8-pin cable, number of rows 1024, operating temperature range
Around -20 ° C 100 °C
DFV60E-22EK01024 1060309
2016-08-17 15:21:43 | Online Data Sheet
If there are any changes, no further notice will be given!
Fluid Sensor | SICK 7
Online Data Sheet
SICK AG | Waldkirch | Germany | www.sick.com
SICK Overview
SICK is one of the major manufacturers of industrial intelligent sensors and sensing technology solutions. The unique range of products and services is safe and effective
Control the process to create an optimal foundation, prevent personal accidents and avoid environmental pollution.
We have extensive experience in various fields and are familiar with their processes and requirements. This way, we can use smart sensors to provide customers with what they need. exist
We will test and optimize system solutions based on customer needs at our application centers in Europe, Asia, and North America. SICK is trustworthy for you
Suppliers and research and development partners.
Comprehensive services further enhance our orders: SICK provides comprehensive services to assist and ensure safety and production throughout the entire lifecycle of machines
Rate.
This is' sensor intelligence 'for us.
Traveling with you globally:
Contact person and location of other branch offices - www.sick.com
Online inquiry