Product Features
- 1. Exquisite appearance design, convenient and user-friendly operation, ABS plastic casing, lightweight and compact in size. 2. Drawer type operation desk, left and right side door opening design and hidden observation window are convenient for taking, placing, observing and cutting gel. The built-in gel placement center indicator light facilitates the positioning of gel in the center. 3. All windows and doors have an overlapping and staggered sealing structure design, enhancing the UV transmission effect and space sealing effect of the darkroom, and minimizing the harm of ultraviolet rays to the human body. 4. Dual intensity transmission ultraviolet wavelength: 302nm, reflection wavelengths: 254365nm. 5. Equipped with imported low light high-resolution digital CCD, it is easy to capture weak spectral bands, browse and display in real time, and operate conveniently. Six times optical manual or automatic zoom lens, easy to zoom and observe gel. 6. Adopting a multi-layer coated filter group to effectively filter out background interference noise; The control functions of zoom, focus, aperture, ultraviolet light, and white light can be achieved through a computer; The control functions of zoom, focus, aperture, ultraviolet light, and white light can also be achieved through the panel. 7. It has functions such as automatic UV cut-off, delayed power-off, and leakage protection when opening the door, which maximizes the protection of users from harm. 8. Equipped with ultra-thin white light board, it adopts internationally leading phosphor screen ultraviolet white light conversion technology. 9. Configure special gel imaging analysis software; Equipped with advanced lane automatic recognition function, it helps identify, move, adjust, and number lanes and bands. Export various experimental reports to text or Excel format files. Calculate and compare the molecular weight, optical density, migration rate, pH value, and percentage content of nucleic acids and proteins. And it has 1D and 2D analysis, DotBlot image processing analysis; Colony and clone counting image analysis function. Used for DNA analysis RNA、 Collection, observation, analysis and preservation of protein and other electrophoretic gel images. 1 Exquisite design, user-friendly operation, ABS plastic case, light weight, small size. 2、Drawer-style gel platform, left and right sides of the door design and hidden observation window, convenient to take and place the gel, observation, cutting. Built-in gel placement center indicator, easy to gel positioning placed in the center position. 3、All open the window to open the door with overlapping dislocation seal structure design, enhance the darkroom of the UV transmission effect and space airtight effect, the maximum to avoid UV damage to the human body. 4、Double intensity transmission UV wavelength: 302nm, reflection wavelength: 254,365nm, transmission ultraviolet area: 250mm ×200mm. 5 Equipped with imported low-light high-resolution digital CCD, easy to capture the weak spectrum, real-time browsing display, easy to operate. Six times the optical manual or automatic zoom lens, easy to observe the scaling of the gel. 6、Adopts multi-layer coating filter group, effectively filter out the background interference noise; through the computer to achieve the control of zoom, focus, aperture, UV lamp and white light function; can also be achieved the control of to control zoom, focus, aperture, UV Lights and white light through the panel. 7、With open the door automatically off the UV, power-off-delay, leakage protection functions, maximum protection of the user from harm. 8、With ultrathin learpanel, using the international leading UV-screen UV white light conversion technology. 9、Configure dedicated gel imaging analysis software; with advanced swimlane automatic identification function, help to identify, move, adjust, and number of swimlanes and bands. Export various experimental reports to text or Excel format files. DCalculation and comparison of nucleic acid, protein molecular weight, optical density, migration rate, PH value and percentage content. And has 1D and 2D analysis, DotBlot image processing analysis; Analysis function of colony and clone counting image. Used for DNA, RNA, protein and other electrophoresis gel image collection, observation and analysis and preservation.
performance index
-
type name
IAS-500
camera
useSony Exmor CMOScamera
Zoom lens
F=1:1.2,2/3Inch import6Zoom lens
Effective pixels
3072×2048
Pixel Density
12bit
pixel size
2.4×2.4μm
Resolution
630megapixel
Sensitivity
Can detect levels below20pgEBStained double chainDNA
Signal to noise ratio
≥56db
Filter
590nm
UV transmittance area
168×210mm
Visible light transmission area
200×250mm
Transmitting area of phosphor screen white light plate
210×260mm
Transmitting ultraviolet light source wavelength
302nm
Reflected ultraviolet light source wavelength
254、365nm
Transmitting UV lamp power
302nm(8W)
Reflected UV lamp power
254nm(11W)The365nm(11W)
Input power supply
AC110V/220V,50/60Hz
fuse
250V 3Aφ5×20
External dimensions
W.450×D.440×H.770mm
clean weight
21.5kgs