VIP member
Gas intelligent pressure controller
The 6000F intelligent gas pressure controller adopts reliable and validated valve technology, and uses high-precision pressure sensors as measurement
Product details
1.1Safety points
1. The power plug of the instrument must be connected to a well functioning deviceGround wireOn the three pin power socket. The normal operating voltage range of the instrument is 190-250VAC, 50HZ.
2. The instrument power fuse is located in the instrument power socket (5A fuse), with one connected for use and the other as a backup. When replacing, the power must be turned off.
1.2Instructions for the back panel of the controller
1. The power plug of the instrument must be connected to a well functioning deviceGround wireOn the three pin power socket. The normal operating voltage range of the instrument is 190-250VAC, 50HZ.
2. The instrument power fuse is located in the instrument power socket (5A fuse), with one connected for use and the other as a backup. When replacing, the power must be turned off.
1.2Instructions for the back panel of the controller
| name | brief |
| OUTPUT | select |
| input sensor | select |
| USB | Please refer to the electronic document for the agreement |
| RS232 | Please refer to the electronic document for the agreement |
| Input positive pressure | It is recommended to add a pressure reducing valve to the input end of the gas source |
| Input negative pressure | Connect the vacuum pump to evacuate, it is recommended to add a one-way valve to prevent oil from flowing into the controller due to vacuum |
| Output air pressure | control output |
1.3Specification parameters
| Pressure measurement | |
| Pressure range (Customizable) |
Absolute pressure: 0-200kPa, 700kPa, 1.7MPa, 3.5MPa, 7MPa Gauge pressure: 0-200kPa, 700kPa, 1.7MPa, 3.5MPa, 7MPa |
| Atmospheric reference range | 75-115kPa absolute pressure (select any range and add atmospheric reference option to achieve absolute pressure/gauge pressure range conversion) |
| Over limit indication | Exceeding the full range pressure range of the pressure sensor by 20% |
| pressure medium | Except for atmospheric pressure sensors, other pressure sensors use 316 isolation diaphragms, but it is still recommended to use dry, oil-free, non corrosive gases. It is recommended to use dry air or nitrogen to avoid the risk of blockage. |
| display | |
| panel | 7.0-inch widescreen color touch screen, equipped with an integrated touch screen |
| Communication update rate | 8 times per second |
| Display update rate reading |
2 times per second ±9999999 |
| Pressure Unit | kPa、bar、MPa、PSI |
| Performance (within the verification temperature range) | |
| Standard accuracy | 0.05% FS includes nonlinearity, hysteresis, repeatability, and temperature effects, assuming steady-state temperature conditions and periodic zeroing. |
| Improve accuracy | 0.025% FS includes nonlinearity, hysteresis, repeatability, and temperature effects, assuming steady-state temperature conditions and periodic zeroing. |
Online inquiry
