Jiedao IslandGC-1690TIntroduction to gas or dimethyl ether gas chromatograph:
Product Name: Gas or Dimethyl Ether Gas Chromatography System
model:GC-1690T
Manufacturer: Jiedao
Coke oven gas, blast furnace gas, converter gas, artificial gas, water gas, and semi water gas are gases closely related to people's production and life, widely used in fields such as *, petrochemicals, metallurgy, and fine chemicals. It is of great significance to calculate the calorific value of various gases by analyzing their composition and the content of each component.
GC-1690TThe gas analysis chromatograph solves the full analysis of gases such as hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide, methane, etc. in gas with a single injection, and can directly calculate the calorific value. Adding optional attachments can also complete the determination of benzene, naphthalene, and hydrogen sulfide.
Jiedao IslandGC-1690TIntroduction to Gas or Dimethyl Ether Gas Chromatography
This instrument is suitable for rapid analysis of water gas, semi water gas, coke oven gas, blast furnace gas, etc.GC-1690The gas chromatograph is equipped with a single valve dual column and a thermal conductivity detector for gas analysis. The components includeH2、O2、N2、CO、CO2,CH4Scope of detectionH2do5%-100%,Other for1ppm-100%(volume fraction)If you want to testH2SAs long as the flame intensity is increased(FPD)Detector andH2SAnalysis column is sufficient, with dual channels in parallel, and can be obtained with one injectionH2S、H2、O2、N2、CO、CO2,CH4The content of components, includingH2Sdetection range1ppm-100%The system has an economical and reasonable configuration, simple operation and maintenance, high analysis efficiency, stable performance, and high repeatability. The analysis time can be controlled within8minor5minWithin.
Jiedao IslandGC-1690TGas or dimethyl ether gas chromatograph configuration:
1.GC1690T(High sensitivity)TCD) 1tower
2.Heating six way sampler 1cover
3.Stainless steel analytical column 2branch
4.Chromatography workstation 1cover
5.Standard gas (including pressure reducing valve) 1Bottle (see table above)
6.High purity helium gas cylinder 1 Bottles (recommended for on-site procurement)
7.Computer and Printer 1Set (recommended for on-site procurement)
8.If we want to detect trace amounts in gasH2SYou need to purchase accessories(1.FPDdetector1tower; 2.H2Sanalytical column1branch; 3.Imported six way valve1cover;)
Note: Gas analysis column2Replace with dimethyl ether column1Zhi, replace the planting gas withH2(SGH-300A)Can become a dimethyl ether gas chromatograph