Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
sketch:
Kore Technology GmbH in Germany has many years of experience in magnetic field testing and has launchedGMR63A weak magnetic field three-dimensional Gaussian meter can be used for air cargo magnetic field detection, accurate detection of geomagnetic field, etc.3.2The inch color industrial touch screen provides rich display content and has the maximum value/minimum value/Maintain value/Alarm threshold, real-time magnetic field strengthXYZFunctions such as component value and vector value.
GMR63The three-dimensional probe of the weak magnetic field three-dimensional Gaussian meter has an exceptionally excellent feature: its probe sensor adopts microelectromechanical manufacturing technology, with high spatial resolution and excellent orthogonality accuracy, and the probe thickness is only2.8mmThe width is only7.2mmIt is very suitable for research institutions, universities, and businesses to use.
GMR63Measurement range of weak magnetic field 3D Gaussian meter600μT, Resolution10nTThe three-dimensional probe option with built-in temperature sensor has temperature compensation function, which can improve the accuracy and stability of measurement data when the temperature changes. Therefore, it is strongly recommended to purchase a probe with built-in temperature sensor.
GMR63The weak magnetic field three-dimensional Gaussian meter has passedCECertification andEMC(electromagnetic compatibility)Testing.
characteristic | |
●Three dimensional magnetic field detection ●Ergonomic design ●Graphical interface operating system ●3.2inchLCDcolorful touch screen ●Maximum value/minimum value/hold function ●Intelligent recording and viewing ●XYZComponent value and vector value display ●4400mAHrechargeable battery |
●The probe thickness is only2.8mm ●The probe width is only7.2mm ●measuring range600uT ●resolution10nT ●DCAccuracy:0.8% ●complete5Position display ●Excellent orthogonality accuracy ●Probe with temperature compensation function optional |
![]() |
![]() |
![]() |
GMR63Three dimensional weak magnetic field Gaussian meter parameters:
model |
GMR63 |
Measurement parameters | |
accuracy/axle(DC) |
±0.8% |
range/axle |
600μT (6G) |
resolution |
10nT (0.1mG) |
Display digits |
5 |
Frequency response range[fT] |
DC - 80Hz |
Typical temperature coefficient |
<±500ppm>±500ppm>℃(Conventional 3D probe) <±100ppm>±100ppm>℃(Probe with built-in temperature sensor) |
front panel | |
display type |
3.2Inch color resistive touch screen,320x240pixel |
Display units |
Gaussian(G)Tesla(T) |
Display update rate |
3order/second |
display mode |
DC、AC、XYZ3D display, maximum value, minimum value, alarm, etc |
probe | |
Compatible probes |
details“Probe specifications”list |
Probe cable length |
standard1.5Rice; |
USBinterface | |
function |
1Communication interface: used for connectingPCMonitor and measure with Gaussian meter host; 2Charging interface: used for connectingPCOr a portable power bank(power bank)Charge the Gaussian meter host. |
software/drive |
Upper computer software, no need to install other drivers |
Host specifications | |
operation temperature |
+15℃to +35℃(accuracy rating) -10℃to +60℃(Reduced accuracy) |
storage temperature |
- 20℃to +60℃ |
Environmental magnetic field |
<> |
battery |
rechargeable4400mAHLithium Ion Battery |
Battery operating time |
>16Hour (standard test environment) |
size |
238 mmW× 95 mmH× 42 mmD |
weight |
350g |
qualification |
CECertificationEMCauthentication |
Probe specifications
![]() |
3D probe | |||||||
probe Type |
maximum range |
resolution |
Frequency response range |
Probe rod size (mm) |
operation temperature |
DCaccuracy (25℃) |
Probe rod material |
Weak magnetic field probe Y06L150GMR63 Y06L150GMR63T |
6G (600μT) |
0.1mG (10nT) |
DC -80Hz |
60*7.2*2.8 |
-20℃- +60℃ |
±0.8% |
plastics |
Note:
1The model contains letters at the end“T”Probe with built-in temperature sensor, equipped with temperature compensation function, and its temperature coefficient<±100ppm>±100ppm>℃;
2Sensor center position and three-axis direction:
Probe selection type description
Y |
06 |
L |
150 |
GMR63 |
T |
probe Type A -Axial probe T -radial probe X - 2 AXIS Y - 3 AXIS
|
Probe length 06 - 6 cm 08 - 8 cm 10 - 10 cm 25 - 25 cm
… |
Probe style C – CRYOGENIC F – FLEXIBLE H – HIGH TEMP. L – LOW FIELD M – METAL P – PLASTIC U – ULTRATHIN W – WIDE FIELD |
Probe cable length 150 – 150cm 300 – 300cm 500 – 500cm
… |
Gaussian meter type GMR63 – GMR63 probe
|
Temperature compensation function (Probe with built-in temperature sensor)
T -have BLANK -not have |