GLM-DHF82 multi-element rapid analyzer
Product Introduction GLM-DHF82 multi-element rapid analyzer is an analyzer developed based on the principle of photometric analysis. It adopts a uniqu
Product details

DFH82.png

Product Introduction

GLM-DHF82Multi-element rapid analyzerIt is an analyzer developed based on the principle of photometric analysis,Adopting unique linear extension and sensitivity improvement methods,Solved the problem of high component content deviation from linearity in traditional photometric analysis,Analyzing the problem of poor sensitivity in low component content.Realized rapid analysis on a large scale and with high precision. It has significant advantages in the field of silicate systems, especially suitable for industries such as ceramics, refractory materials, cement, glass, geology, non-metallic minerals, etc. This product has been widely used in colleges, research institutes, factories, and mining enterprises, and has entered the international market.

Main technical parameters

1-1Measurement elements and scope

SiO20.2-99% Al2O3 0.2-99% Fe2O3 0.1-99%  TiO2 0.1-99%

K2O 0.1-15% Na2O0.1-15% CaO  0.1-99% MgO 0.1-99%

B2O3 0.1-30% ZrO2 0.1-99% Li2O0.1-15% SnO 0.1-99%

PbO 0.1-99% ZnO 0.1-99% MnO 0.1-15% Cr2O3 0.1-15%

BaO 0.1-10% NiO 0.1-15% CoO 0.1-10% P2O5 0.1-30%

1-2Rapid analysis of the main components of the following chemical raw materials

Chromium salt productsV2O5ProductMnOProductNiOProducts, titanium dioxide, phosphate, cobalt oxide, zinc oxide, boric acid, borax, water glass, sodium humate.

1-3High precision analysis of low content components

Can beFe2O3TiO2K2ONa2OCaOMgOP2O5MnOCr2O3Extend the detection limit of elements to0.02%The analysis accuracy is better than0.02%.

2Analysis accuracy: the analysis accuracy of each elementequalExceeding the allowable error specified in the relevant national standard analysis methods.

3Analysis speed: Starting from self proclaimed quantity2-3Completed in hoursSiO2  Al2O3Fe2O3TiO2K2ONa2OCaOMgOComplete analysis.

4Sample injection channel:3individual

5Continuous measurement of sample quantity:10individual

Instrument working conditions

1Power supply220V 50HZ 2Whole machine power1KW 3Weight of the whole machine100Kg

4Installation area3500×850mm 5Environmental temperature530 6Relative humidity less than85%