GC-8860 gas chromatograph (full EPC)
● Operation display: 7-inch color LCD touch screen, can be used as a handheld controller ● Temperature control area: 8 channels; Temperature control r
Product details

● Operation display: 7-inch color LCD touch screen, can be used as a handheld controller

Temperature controlled area: 8 channels; Temperature control range: 4 ℃ to 450 ℃ above room temperature,

Increment: 0.5 ℃; Accuracy: ± 0.1 ℃

● Program heating stage: 20 stages, lift rate: 0.1-120 ℃/min

● Air path control:The entire EPC electronic pressure and flow control system can choose to set the carrier gas and tail gas blowing types: He, H2, N2, and Ar. Each carrier gas system can achieve constant pressure, constant current, constant speed, program pressure, program flow, and program linear velocity gas control modes.

Range: 0-100psi (pressure);

0-1000mL/min (flow rate), resolution: 0.01Psi (pressure);

0.01 mL/min (flow rate); Maximum diversion ratio: 1:7500

External events: 8 channels; Auxiliary control output 2 channels

Type of injector: packed column injection, capillary injection, six way valve gas injection, automatic injector

Number of detectors: 3 (maximum); FID, TCD, ECD, FPD, and NPD are optional

● Start injection: manual or automatic options are available

● Communication interface: Ethernet: IEEE802.3,Signal acquisition rate: 1200Hz; Has a retention time lock.

Temperature control range: 4 ℃ to 450 ℃ above room temperature(Set in increments of 1 ℃)

Automatic ignition, capable of withstanding 100000 ignition cycles

Carrier gas (column head pressure)

Carrier gas: EPC electronic pressure flow control range: 0-100psi

Diversion and emptying

Diversion: Maximum diversion ratio: 1:7500

Gap pad blowing

Maximum diversion ratio: 1:7500

Hydrogen flame ionization detector (FID)

Detection limit: ≤ 1×10-12G/S (n-hexadecane)

Baseline noise: ≤ 2×10-14A

Baseline drift: ≤ 1×10-13A/30min

◆ Linear range: ≥ ten7

ECd(ECD)

◆ ≤ 5 × 10-14g/ml (Hexachlorocyclohexane Isooctane Solution)

Baseline noise: ≤ 0.03mv

Baseline drift: ≤ 0.2mV/30min

◆ Linear range: ≥ ten3

Flame photometric detector (FPD)

◆ Detection limit: (S)≤5×10-11G/s, (P) ≤ 1 × 10-12G/s (Methyl parathion anhydrous ethanol solution)

Baseline noise: ≤ 3×10-13A

Baseline drift: ≤ 2×10-12A/30min

injector

Supports up to 256 sample grades