This series of ventilation fans has reliable performance, high efficiency, low noise, simple structure, and easy installation. Suitable for ventilation and heat dissipation of variable frequency speed regulating motors.
Usage environment:
The ambient air temperature varies with the seasons, but does not exceed 40 ℃; When the relative temperature of the surrounding air is greater than 90% and the temperature is 25 ℃.
remarks:
The specifications listed in the sample (Type A) are standard types, and the following types can be made according to the user's special requirements:
1. Change the structure of dimensions such as L1, L2, and L3;
2. Make a vertical structure with a rain cover (the standard type is horizontal);
3. Make a left outlet (standard type is right outlet) and a top outlet structure;
4. The casing can be made to accommodate structures such as brakes and encoders;
5. The fan motor may have special requirements such as different voltage and frequency electrical systems, improved protection level, and increased insulation level (standard model electrical system 380V50HZ, protection level IP55, insulation level F).
Outline and installation dimension diagram:
Note: 1.3 elongated circular holes (n=3) are uniformly distributed in the E direction; Four elongated circular holes (n=4) are uniformly distributed in the F-direction;
2. The diameter d is the refueling hole, of which G71A-132A does not have a refueling hole (diameter d does not require machining);
Do G160A-225A require oil filling holes (to be machined when specified in the order);
G250A-355A has an oil filling hole (diameter d needs to be machined).
3. The chassis shown in the diagram has a right outlet structure, which can also be made into a left outlet and top outlet structure; If the top outlet structure is made with 3 elongated circular holes (n=3) or a top outlet structure with an oil filling hole (φ d), if there is interference between the installation hole or oil filling hole and the junction box, the junction box will be moved 5mm or extended L2 in the opposite direction of the installation hole or oil filling hole, and the specific size will be linked to ABB.
Main technical parameters:
model | D1 | D2 | L1 | L2 | L3 | L4 | β | η | R | n | X | d | notes |
G-71A | 132 | 136 | 12 | 42 | 136 | 1.5 | 4 | 3 | 3 | 8 | No refueling hole | ||
G-80A | 150 | 155 | 8 | 32 | 150 | 1.5 | 4 | 3 | 3 | 15 | No refueling hole | ||
G-90A | 169 | 172.5 | 14 | 39 | 155 | 1.5 | 4 | 3 | 3 | 12 | No refueling hole | ||
G-100A | 188 | 193 | 14 | 46 | 162 | 1.5 | 5 | 3.5 | 3 | 12 | No refueling hole | ||
G-112A | 210 | 217 | 14 | 51 | 166 | 1.5 | 5 | 3.5 | 3 | 12 | No refueling hole | ||
G-132A | 250 | 258 | 20 | 62 | 177 | 1.5 | 5 | 3.5 | 3 | 15 | No refueling hole | ||
G-160A | 300 | 308 | 20 | 86 | 201 | 33 | 2 | 5 | 3.5 | 4 | 15 | 20 | Is there a fuel hole according to the order requirements |
G-180A | 340 | 352 | 25 | 96 | 248 | 34.5 | 2 | 5 | 3.5 | 4 | 12 | 20 | Is there a fuel hole according to the order requirements |
G-200A | 380 | 394 | 30 | 110 | 262 | 45 | 2 | 6 | 4.5 | 4 | 12 | 20 | Is there a fuel hole according to the order requirements |
G-225A | 430 | 443 | 31 | 106 | 268 | 36 | 2 | 6 | 4.5 | 4 | 12 | 20 | Is there a fuel hole according to the order requirements |
G-250A | 470 | 482 | 29 | 150 | 312 | 40 | 2 | 8 | 5 | 4 | 12 | 20 | There is a fuel hole |
G-280A | 530 | 546 | 34 | 156 | 370 | 36.5 | 2 | 9 | 5.5 | 4 | 12 | 20 | There is a fuel hole |
G-315A | 600 | 616 | 82 | 222 | 436 | 38 | 2 | 13 | 6 | 4 | 12 | 20 | There is a fuel hole |
G-355A | 680 | 694 | 124 | 265 | 480 | 38 | 2 | 13 | 6 | 4 | 12 | 20 | There is a fuel hole |
G-400A | 700 | 787 | 82 | 280 | 500 | 38 | 3 | 13 | 6 | 4 | 12 | 20 | There is a fuel hole |
model | Electric system (three-phase) | Power (W) | Current (A) | Speed (r/min) | Airflow (m ³/h) | Total pressure (Pa) | Noise dB (A) | Blade diameter (mm) |
G-71A | 380V 50Hz | 35 | 0.09 | 2800 | 200 | 42 | 63 | 131 |
G-80A | 380V 50Hz | 60 | 0.24 | 2800 | 350 | 60 | 64 | 150 |
G-90A | 380V 50Hz | 60 | 0.24 | 2800 | 500 | 80 | 67 | 169 |
G-100A | 380V 50Hz | 60 | 0.24 | 2800 | 650 | 82 | 69 | 186 |
G-112A | 380V 50Hz | 60 | 0.24 | 2800 | 1000 | 110 | 71 | 210 |
G-132A | 380V 50Hz | 60 | 0.24 | 2800 | 1000 | 70 | 74 | 250 |
G-160A | 380V 50Hz | 60 | 0.24 | 2800 | 1000 | 40 | 65 | 300 |
G-180A | 380V 50Hz | 180 | 0.71 | 1400 | 1200 | 55 | 69 | 340 |
G-200A | 380V 50Hz | 180 | 0.71 | 1400 | 1800 | 65 | 70 | 380 |
G-225A | 380V 50Hz | 230 | 0.71 | 1400 | 2750 | 82 | 76 | 430 |
G-250A | 380V 50Hz | 230 | 0.71 | 1400 | 3300 | 85 | 77 | 470 |
G-280A | 380V 50Hz | 370/280 | 1.1 | 1400 | 4000 | 110 | 79 | 530 |
G-315A | 380V 50Hz | 370/500 | 1.45 | 1400 | 5200 | 150 | 80 | 600 |
G-355A | 380V 50Hz | 500 | 1.8 | 900 | 6200 | 100 | 75 | 680 |
G-400A | 380V 50Hz | 500 | 1.8 | 900 | 6500 | 85 | 78 | 720 |
Note: The diameter d is the refueling hole, of which: 1. G71A does not have a refueling hole (diameter d does not require processing); 2. Do G160A-225A require oil filling holes to be specified when placing an order (with a diameter of φ d to be processed when requested in the order); 3. G250A-400A has an oil filling hole (diameter d needs to be machined).