Hebi Kaike Analytical Instrument Co., Ltd
Home>Products>Fully automatic fluoride and chloride ion analyzer
Fully automatic fluoride and chloride ion analyzer
Minimum order quantity: 1 unit Supply quantity: 100 units Product origin: Hebi, China Product grade: premium Product brand: Hebi Kaike Product packagi
Product details

全自动氟氯离子测定仪Fully automatic fluoride and chloride ion analyzer


Functional characteristics of hydrolysis part

1Using Chinese7The inch LCD touch screen displays temperature, sample delivery location, and delivery time at all times, with a user-friendly interface and simple operation.

2The program can be edited according to user needs.

3Furnace temperature adoptedPIDControl furnace flow, high temperature control accuracy, effectively extending the service life of silicon carbon tubes.

4Spiral stainless steel sample sending mechanism, sample sending distance, sample sending position, and sample sending speed can be set freely.

5The heating rate can be adjusted freely and can be directly connected to a socket for use.

6Fully automatic sample delivery, dispensing, automatic sealing plug, automatic opening of the plug, and automatic reset of the plug.

7The evaporation rate can be adjusted freely, the steam is stable, and the service life is long.

8Equipped with imported high-precision digital electrodes to ensure the accuracy of the experiment.

Functional characteristics of titration section:

Equipped with fully automatic titration software, it can be used forWIN10Computer operating system, titration solution can be set, titration speed can be freely set according to sample characteristics, data results can be queried, exported and uploaded; Both fluorine and chlorine can be automatically titrated, calculated, and the measurement results generated automatically.

Technical parameters:

1 Temperature measurement accuracy:0. 1℃;

2 Temperature control accuracy:1100±1℃;

3 Heating time:25Heat up in about minutes1100±1℃;

4 Temperature setting range:100—1200℃;

5 Potential resolution:0.1mV

6 Current opening setting range:0-200

7 Testing method: High temperature combustion hydrolysis method;

8 refined secret Degree: Fluorine meetsGB/ T4633—2014national standard,Measurement range:10-2000ug/g;

Chlorine meetsGB/ Tnational standard,Measurement range:0.003%-45%

9 Power supply:AC220V±10%50Hz

10Overall power:3.5KW

11Weight of the whole machine:60kg

12Titration system size:583*356*361