Formaldehyde gas inlet sensor detection module BYC02
The BYC02 atmospheric air quality automatic observation system for formaldehyde gas import sensor detection module has the following leading advantage
Product details
1、 Introduction to formaldehyde gas import sensor detection module
The BYC02 formaldehyde sensor module adopts imported Dat electrochemical gas sensor calibration output signals TTL and IIC, designed for low-cost application users of integrators. The experimental chamber is uniformly calibrated, and the data is stable and reliable.
2、 Application fields of formaldehyde gas import sensor detection module
This product is widely used in scientific research institutions, portable/handheld detectors, fixed gas transmitters, atmospheric environment detectors, industrial toxic and harmful gas transmitters, etc.
3、 Formaldehyde gas
Formaldehyde is also known as formaldehyde. Colorless gas, with a special irritating odor, has a stimulating effect on human eyes, nose, etc. Easy to dissolve in water and ethanol. The concentration of aqueous solution can reach up to 55%, usually 40%. It is called formaldehyde water, commonly known as formalin, and is a colorless liquid with a pungent odor. The main harm of formaldehyde is its irritating effect on the skin and mucous membranes. When formaldehyde reaches a certain concentration indoors, people feel uncomfortable. Formaldehyde concentrations greater than 0.08mg/m ³ can cause redness, itching, discomfort or pain in the throat, hoarseness, sneezing, chest tightness, wheezing, dermatitis, etc. The newly renovated room has a high formaldehyde content, which is the main cause of many diseases.
4、 Technical parameters of formaldehyde gas import sensor detection module
Technical Parameter | BYC02 |
Detect gas | Formaldehyde (HCHO) |
Detection Principle | Principle of Electrochemical Detection |
measuring range | 0-2.00ppm |
resolution | 0.01ppm |
accuracy | Within 0.5ppm, ± 0.03ppm; 0.5ppm~2ppm, ± 10% reading ± 0.05ppm or ± 0.2ppm (whichever is greater) |
Sensor lifespan | 2-3 years service life |
Warm-up time | <180S |
sampling interval | 3S |
Response time (T90) | <30S |
Nonlinear | ±2% |
repeatability | ±2% |
Supply Voltage | DC 5V or 3.3V |
power consumption | ﹤65 mW |
signal output | TTL and IIC |
work environment | -20~50℃; 0-95% RH (no condensation) |
Environment | -40~60℃; 0-100% RH (no condensation) |
Weight/Size | 32mm (length) x 25mm (width) x 16.7mm (height), with needle arrangement, needle arrangement specification is 2.54 x 7pin |
Fixed hole spacing | 17.7mm × 17.7mm × Φ 3.5 diagonal two through holes (see attached figure) |
notes | |
5、 Packaging size of formaldehyde gas import sensor detection module

6、 Pin definition of formaldehyde gas import sensor detection module
order | Pin marking | Parameter | data | notes |
Pin 1 | SCL | I2C pin | ||
Pin 2 | SDA | I2C pin | ||
Pin 3 | +5V | Supply Voltage | Maximum 5V ± 0.1V | (+5v) |
Pin 4 | GND | Ground (negative pole) | Common ground | |
Pin 5 | TX | TTL UART | 9600BPS, 8-bit, no checksum, 1 stop position The default address is: 01 |
|
Pin 6 | RX | TTL UART | ||
Pin 7 | EA | Serial port output enable control | ||
Pin 1 | 3.3V | |||
Pin 2 | GND |

Online inquiry