Focbar differential pressure transmitter
Stable and reliable, with a long-term drift performance of ± 0.1%/year, an extremely wide measurement range of 100Pa to 60MPa, and an adjustable range
Product details

Working principle

The Focbar (Intelligent) monocrystalline silicon pressure transmitter adopts the world's advanced monocrystalline silicon pressure sensor technology and patented packaging process, and has been carefully developed as an internationally leading technology ultra-high performance pressure transmitter. The monocrystalline silicon pressure sensor is located at the top of the metal body, away from the contact surface of the medium, to achieve mechanical and thermal isolation; The sensor lead integrated with glass sintering achieves high-strength electrical insulation with the metal substrate, improving the flexibility and ability to withstand transient voltage protection of electronic circuits. These innovative monocrystalline silicon pressure sensor packaging technologies ensure that the Focp (intelligent) monocrystalline silicon pressure transmitter can handle extreme chemical and mechanical loads with ease, while also possessing strong electromagnetic interference resistance, capable of handling harsh industrial environmental applications, making it a truly invisible instrument.

Structural components -----------------------------------------------------------------------

1. Front cover of header 2 Front cover lens 3. Header 4. Shell 5. Nameplate label 6. Explosion proof connector 7. Wiring terminal 8. Header back cover 9. Drain valve 10 Bolt 11. Clamp plate 12. Sensor sealing ring 13. Sensor 14. Nut 15. Welded pipe joint assembly

Product Features

Advanced monocrystalline silicon pressure sensor technology and patented packaging process, carefully developed into an internationally leading high-performance pressure transmitter
◆ Dual membrane overload structure, capable of handling high overload tests with ease
A signal transmission module using integrated circuits and surface packaging technology, with a powerful 24 bit ADC to achieve high precision and fast response
The display module can rotate 355 °, and the button parameter operation function is friendly
The setting of key parameters does not affect the electrical protection level, making it safer and faster
◆ High performance Focbar monocrystalline silicon pressure transmitter, perfect combination of international leading technology and Chinese intelligent manufacturing
◆ Sturdy and high-quality stainless steel process flange, thick reinforced structure, indestructible, strong guarantee of high static pressure and high overload

Product Parameters/Product Parameters ------------------------------------------

1. Main technical parameters
name Monocrystalline silicon differential pressure transmitter
application Liquid, gas, steam
measuring range 200pa-10Mpa
accuracy class ± 0.075% range upper limit, optional ± 0.05% range upper limit
Supply Voltage 24V DC
output signal 4-20mA, 4-20mA+HART
operation temperature -40~85℃
medium temperature -40~120℃
DIAPHRAGM MATERIAL 316L, Hastelloy C
protection grade IP67

Product Dimensions/Product Dimensions ---------------------------------------

Range and Range Limits/Range and Range Limits ----------------------------------

Nominal range minimum range Lower Range Limit (LRL) Range upper limit (URL) Static pressure range One way high voltage end overload One way low voltage end overload
6kPa 200Pa -6kPa 6kPa 25MPa 25MPa 16MPa
40kPa 400Pa -40kPa 40kPa 40MPa 25MPa 16MPa
250kPa 2.5kPa -250kPa 250kPa 40MPa 25MPa 16MPa
1MPa 10kPa -500kPa 1MPa 40MPa 25MPa 16MPa
3MPa 30kPa -500kPa 3MPa 40MPa 25MPa 16MPa
10MPa 100kPa -500kPa 10MPa 40MPa 25MPa 16MPa
Requirements for setting high and low limit values: The low limit value (LRV) and high limit value (URV) should be taken within the upper and lower limits of the range. When | URV | ≥ | LRV |, | URV | ≥ minimum range must be met; When | URV | ≤ | LRV |, it is necessary to meet | LRV | ≥ minimum range
1. Performance testing standards and benchmark conditions
Testing standards: GB/T28474/IEC60770; Reference conditions: range starting from zero; Silicone oil filling, 316L stainless steel isolation diaphragm, 4-20mA analog output, fine tune the end group to the set value
2. Performance indicators
The overall performance includes but is not limited to the comprehensive error of reference accuracy, environmental temperature influence, static pressure influence, and other influences
Typical accuracy: ± 0.075% range upper limit
Annual stability: ± 0.2% range upper limit/5 years
3. Reference accuracy
According to standards and testing benchmark conditions, including linearity (BFSL), hysteresis, and repeatability. Calibration temperature: 20 ℃± 5 ℃
Linear output accuracy TD ≤ 10 (Note 1) ± 0.075% upper range limit Nominal range: 6kPa, 40kPa, 250kPa, 1MPa, 3MPa, 10MPa
10<TD≤100 ± 0.0075TD% upper range limit
The square root output accuracy is 1.5 times the linear reference accuracy mentioned above
Note 1: TD (Turn down) refers to the range ratio. When | URV | ≥ | LRV |, TD=URL/| URV |. When | URV | ≤ | LRV |, TD=URL/|LRV|
4. Environmental temperature impact
Total impact within the range of -20-80 ℃ ± (0.1+0.1TD)% range upper limit
5. Static pressure influence
Zero point impact: ± 0.15TD% range upper limit/10MPa, full-scale impact: ± 0.2% range upper limit/10MPa
6. Power supply impact
When the supply voltage varies within 10.5/16.5-55VDC, the changes in zero point and range should not exceed ± 0.005% of the upper range limit/V
7. Installation location impact
Installed at any position, with a maximum pressure not exceeding 400Pa, can be calibrated through the reset function
8. Vibration impact
Tested according to GB/T1827.3/IEC61298-3,<0.1% upper range limit
9. Output signal
Two line 4-20mA, user selectable linear output or square root output, digital process variables superimposed on the 4-20mA signal, suitable for any host that complies with the HART protocol

Specification Parameters/Specification Parameters

1. Time indicator
Total damping time constant: equal to the sum of the damping time constants of electronic circuit components and sensing enclosures
Damping time of electronic circuit components: adjustable within the range of 0-100 seconds
Damping time of sensing membrane box (isolation sensing membrane and silicone oil filling liquid): ≤ 0.2S
Power on startup time after power outage: ≤ 6S
Data recovery to normal usage time: ≤ 31S
2. Weight
Net weight: approximately 4kg (without installation bracket, process connection accessories)
3. Environmental conditions
Net weight: approximately 4kg (without installation bracket, process connection accessories)
Operating temperature range: -40-85 ℃, integrated LCD display:- 20-70℃
Storage environment temperature range: -40-110 ℃, integrated LCD display:- 40-85℃
Temperature range of measuring medium: filled with silicone oil sensor: -40-120 ℃, filled with fluorine oil sensor:- 10-80℃
Operating environment humidity range: 5-100% RH@40 ℃
Protection level: IP67

Power Supply:

project operation condition
Standard/Explosion proof type 10.5-55VDC
HART communication protocol 16.5-55VDC, with a load resistance of 250 Ω during communication
load resistance 0-2119 Ω is the working state, 250-600 Ω
HART communication
Distance <1000 meters
power consumption ≤ 500mW@24VDC , 20.8mA

Power supply and load conditions

Installation and Use/Installation and Use

1. Installation dimension diagram of pipe bending bracket (B1) (unit: mm)
2. Installation dimension diagram of board bending bracket (B2) (unit: mm)
3. Installation dimension diagram of pipe mounted flat bracket (B3) (unit: mm)