Principle: The structural turbine flowmeter is a velocity flowmeter. Place a turbine at the center of the pipeline, supported by bearings at both ends
Product details

Principle, structure

Turbine flowmeter is a type of velocity flowmeter. Place a turbine at the center of the pipeline, supported by bearings at both ends. When fluid passes through the pipeline, it impacts the turbine blades, generating a driving torque on the turbine, which overcomes friction torque and fluid resistance torque to rotate. Within a certain flow range, the viscosity of the fluid medium and the rotational angular velocity of the turbine are proportional to the fluid flow velocity. Therefore, the fluid flow velocity can be obtained by the rotational angular velocity of the turbine, and the fluid flow rate through the pipeline can be calculated. The speed of the turbine is detected by a sensing coil installed outside the casing. When the turbine blades cut the magnetic field lines generated by the permanent magnet inside the casing, it will cause changes in the magnetic flux in the sensing coil. The sensing coil sends the detected magnetic flux periodic change signal to the preamplifier, amplifies and shapes the signal, generates a pulse signal proportional to the flow rate, and sends it to the unit conversion and flow integration circuit to obtain and display the accumulated flow value; At the same time, the pulse signal is also sent to the frequency current conversion circuit, which converts the pulse signal into an analog current quantity and indicates the instantaneous flow rate value.

涡轮流量计

main features

Excellent repeatability, suitable for ingredients

Excellent low flow velocity measurement performance

Extremely fast response, suitable for use in batch control and proportioning control scenarios

Multi blade structure rotor with high precision

Steam cleaning is allowed

Compact type suitable for equipment installation

application

Finished oil, light crude oil, gasoline, light oil, jet fuel, light diesel, naphtha, ethylene, etc

Lubricating oil, hydraulic oil, etc

Water, pure water, distilled water, deionized water, desalinated water, softened water, etc

Alcohol, benzene, toluene, xylene, butadiene, carbon tetrachloride, methylamine, acrylonitrile, etc

Formaldehyde, oxalic acid, caustic soda, carbon disulfide, etc

Milk, coffee, etc

High temperature media such as thermal oil and kerosene

Indicator parameters

performance parameter
Accuracy: There are two types of rates: 0.5% of rate and 0.25% of rate
Repeatability: ± 0.1% of the measured value
Response time: Maximum 50 milliseconds relative to input change
Stability: Stability for more than 6 months is ± 0.1% of the measured value
The impact of environmental temperature: Exceeding the working temperature range is ± 0.25% of the measured value
The impact of installation location: It is necessary to ensure that the sensor is fully loaded and that there are sufficient straight pipe sections in front and behind, in order to ensure installation without any impact
Start time: Starting from zero traffic takes 50 milliseconds
Preheating time: It takes 5 minutes from power on to reaching the rated measurement accuracy
Sensor parameters
Size: DN4 to DN250
Temperature range of the tested fluid: -40... 120 ℃, (>120 ° C and ≤ 180 ° C for customized models, please contact the sales engineer by letter)
Sensor body material: Stainless steel 1.4301 (304), stainless steel 1.4435 (316L)
Material of impeller and accessories: Material of impeller and accessories: 430F stainless steel, stainless steel 1.4435 (316L)
Voltage resistance level: PN10 to PN63
Coil impedance: 1600Ω
Terminal box parameters
Environmental temperature range: -20 to 140° F (-29 to 60 ℃ )
Material of junction box: Stainless steel 1.4301 (304), IEC60529 IP66 (standard), customizable stainless steel 1.4435 (316L)
Converter sealing ring: O-ring rubber seal
Power Supply: DC 12V to 30V, 1A quick fuse;
Protection level: IP65&IP67
Electrical interface: PG13.5
Power: max 0.3 W
Output: Pulse output (for total quantity)

Sensor size and flow range

Size (mm) Measurable flow range (flow velocity affects accuracy) Size (mm) Measurable flow range (flow velocity affects accuracy)
Minimum m ³/h Maximum m ³/h Minimum m ³/h Maximum m ³/h
4
0.04
0.25
50
4
40
6
0.1
0.6
65
8
80
10
0.2
1.2
80
10
100
15
0.6
6
100
20
200
20
0.8
8
125
30
300
25
1
10
150
40
400
32
1.2
12
200
80
800
40
2
20
250
120
1200

FR55-F flange type external dimensions

FR55-F法兰型外形尺寸
Size (mm) Flange end face size L (mm) Outer diameter of flange D (mm) Height H (mm) Approximately weight (kg)
PN16 PN40 PN16 PN40 PN16 PN40
10 80 90 90 144 144 3.0 3.0
15 75 95 95 146 146 3.0 3.0
20 85 105 105 151 151 4.0 4.0
25 100 115 115 156 156 4.5 4.5
32 120 140 140 169 169 6.0 6.0
40 140 150 150 180 180 7.0 7.0
50 150 165 165 192 192 9.0 9.0
65 175 185 185 210 210 11.0 11.0
80 200 200 200 224 224 13 13
100 220 220 235 244 251 16.0 19.0
125 250 250 270 271 281 23 27
150 300 285 300 300 307 31.0 37.0
200 360 340 375 353 370 43 53
250 420 395 450 406 433 64.0 80.0

FR55-T threaded connection type external dimensions

FR55-T螺纹连接型外形尺寸

FR55-T external dimensions thread type

Size (mm) End face size L (mm) Outer diameter of the body A (mm) thread specification Height H (mm)
4 50 36 M30*1.5 109
6 50 36 M30*1.5 109
10 50 36 M30*1.5 109
15 75 40 G1 113
20 85 44 G1 117
25 100 52 G1-1/4 125
32 120 58 G1-1/2 131
40 140 69 G2 142
50 150 81 G2-1/2 154

FR55-C clamp connection type external dimensions

FR55-C external dimensions clamp connection

Size (mm) End face size L (mm) Outer diameter of the body A (mm) thread specification Height H (mm)
15 75 51 51 124
20 80 51 51 124
25 100 51 51 124
32 120 51 51 124
40 140 64 64 137
50 150 77.5 77.5 151
65 175 91 91 164

Model Selection Table

FR55- turbine meter
orifice
DN4 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 (special pipe diameters such as DN300 are agreed upon for delivery)
output signal
Pulse+4 to 20mA current signal
Pulse+0 to 5V voltage signal
High point low point normally open contact signal (switch value full range setting)
Connection method
Threaded sealed connection
Flange connection
Quick sealing hose connector
Sanitary grade clamp connection
accuracy
Accuracy 0.2% (applicable to pipelines above DN15)
Accuracy 0.5% (applicable to pipelines above DN10)
Accuracy 1.0%
Material of the liquid receiving body
Stainless steel 1.4301 (304)
Stainless steel 1.4435 (316L)
Voltage resistance level
EN 1092-1(DIN) PN10 ASME B16.5(ANSI)CLASS150
EN 1092-1(DIN) PN16 ASME B16.5(ANSI)CLASS300
EN 1092-1(DIN) PN25 ASME B16.5(ANSI)CLASS600
EN 1092-1(DIN) PN40 ASME B16.5(ANSI)CLASS900
EN 1092-1(DIN) PN63 ASME B16.5(ANSI)CLASS1500
EN 1092-1(DIN) PN100 ASME B16.5(ANSI)CLASS2500
EN 1092-1(DIN) PN250 JIS 10K
EN 1092-1(DIN) PN400 JIS 20K
Special standards for product application areas
System power supply mode
12 to 24V DC
86 to 265V AC
3.6V lithium battery (for pulse signal or display selection only)
BODY MATERIAL
Stainless steel 1.4301 (304)
Stainless steel 1.4435 (316L)
Hastelloy C
Internal impeller and accessory material
430F stainless steel
Stainless steel 1.4435 (316L)
Hastelloy C
Bearing material
Stainless steel 440C ball bearing (non water environment)
Ceramic journal bearings
Graphite journal bearing
Tungsten carbide journal bearing
(Special alternative) VARIO
Customized with special parameters
The above selection table does not include selection codes. If you need selection codes, please contact us or fill in your information
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!