Principle, structure
Turbine flowmeter is a type of velocity flowmeter. Place a turbine at the center of the pipeline, supported by bearings at both ends. When fluid passes through the pipeline, it impacts the turbine blades, generating a driving torque on the turbine, which overcomes friction torque and fluid resistance torque to rotate. Within a certain flow range, the viscosity of the fluid medium and the rotational angular velocity of the turbine are proportional to the fluid flow velocity. Therefore, the fluid flow velocity can be obtained by the rotational angular velocity of the turbine, and the fluid flow rate through the pipeline can be calculated. The speed of the turbine is detected by a sensing coil installed outside the casing. When the turbine blades cut the magnetic field lines generated by the permanent magnet inside the casing, it will cause changes in the magnetic flux in the sensing coil. The sensing coil sends the detected magnetic flux periodic change signal to the preamplifier, amplifies and shapes the signal, generates a pulse signal proportional to the flow rate, and sends it to the unit conversion and flow integration circuit to obtain and display the accumulated flow value; At the same time, the pulse signal is also sent to the frequency current conversion circuit, which converts the pulse signal into an analog current quantity and indicates the instantaneous flow rate value.

main features
Excellent repeatability, suitable for ingredients
Excellent low flow velocity measurement performance
Extremely fast response, suitable for use in batch control and proportioning control scenarios
Multi blade structure rotor with high precision
Steam cleaning is allowed
Compact type suitable for equipment installation
application
Finished oil, light crude oil, gasoline, light oil, jet fuel, light diesel, naphtha, ethylene, etc
Lubricating oil, hydraulic oil, etc
Water, pure water, distilled water, deionized water, desalinated water, softened water, etc
Alcohol, benzene, toluene, xylene, butadiene, carbon tetrachloride, methylamine, acrylonitrile, etc
Formaldehyde, oxalic acid, caustic soda, carbon disulfide, etc
Milk, coffee, etc
High temperature media such as thermal oil and kerosene
Indicator parameters
performance parameter | |
Accuracy: | There are two types of rates: 0.5% of rate and 0.25% of rate |
Repeatability: | ± 0.1% of the measured value |
Response time: | Maximum 50 milliseconds relative to input change |
Stability: | Stability for more than 6 months is ± 0.1% of the measured value |
The impact of environmental temperature: | Exceeding the working temperature range is ± 0.25% of the measured value |
The impact of installation location: | It is necessary to ensure that the sensor is fully loaded and that there are sufficient straight pipe sections in front and behind, in order to ensure installation without any impact |
Start time: | Starting from zero traffic takes 50 milliseconds |
Preheating time: | It takes 5 minutes from power on to reaching the rated measurement accuracy |
Sensor parameters | |
Size: | DN4 to DN250 |
Temperature range of the tested fluid: | -40... 120 ℃, (>120 ° C and ≤ 180 ° C for customized models, please contact the sales engineer by letter) |
Sensor body material: | Stainless steel 1.4301 (304), stainless steel 1.4435 (316L) |
Material of impeller and accessories: Material of impeller and accessories: | 430F stainless steel, stainless steel 1.4435 (316L) |
Voltage resistance level: | PN10 to PN63 |
Coil impedance: | 1600Ω |
Terminal box parameters | |
Environmental temperature range: | -20 to 140° F (-29 to 60 ℃ ) |
Material of junction box: | Stainless steel 1.4301 (304), IEC60529 IP66 (standard), customizable stainless steel 1.4435 (316L) |
Converter sealing ring: | O-ring rubber seal |
Power Supply: | DC 12V to 30V, 1A quick fuse; |
Protection level: | IP65&IP67 |
Electrical interface: | PG13.5 |
Power: | max 0.3 W |
Output: | Pulse output (for total quantity) |
Sensor size and flow range
Size (mm) | Measurable flow range (flow velocity affects accuracy) | Size (mm) | Measurable flow range (flow velocity affects accuracy) | ||
Minimum m ³/h | Maximum m ³/h | Minimum m ³/h | Maximum m ³/h | ||
4
|
0.04
|
0.25
|
50
|
4
|
40
|
6
|
0.1
|
0.6
|
65
|
8
|
80
|
10
|
0.2
|
1.2
|
80
|
10
|
100
|
15
|
0.6
|
6
|
100
|
20
|
200
|
20
|
0.8
|
8
|
125
|
30
|
300
|
25
|
1
|
10
|
150
|
40
|
400
|
32
|
1.2
|
12
|
200
|
80
|
800
|
40
|
2
|
20
|
250
|
120
|
1200
|
FR55-F flange type external dimensions

Size (mm) | Flange end face size L (mm) | Outer diameter of flange D (mm) | Height H (mm) | Approximately weight (kg) | |||
PN16 | PN40 | PN16 | PN40 | PN16 | PN40 | ||
10 | 80 | 90 | 90 | 144 | 144 | 3.0 | 3.0 |
15 | 75 | 95 | 95 | 146 | 146 | 3.0 | 3.0 |
20 | 85 | 105 | 105 | 151 | 151 | 4.0 | 4.0 |
25 | 100 | 115 | 115 | 156 | 156 | 4.5 | 4.5 |
32 | 120 | 140 | 140 | 169 | 169 | 6.0 | 6.0 |
40 | 140 | 150 | 150 | 180 | 180 | 7.0 | 7.0 |
50 | 150 | 165 | 165 | 192 | 192 | 9.0 | 9.0 |
65 | 175 | 185 | 185 | 210 | 210 | 11.0 | 11.0 |
80 | 200 | 200 | 200 | 224 | 224 | 13 | 13 |
100 | 220 | 220 | 235 | 244 | 251 | 16.0 | 19.0 |
125 | 250 | 250 | 270 | 271 | 281 | 23 | 27 |
150 | 300 | 285 | 300 | 300 | 307 | 31.0 | 37.0 |
200 | 360 | 340 | 375 | 353 | 370 | 43 | 53 |
250 | 420 | 395 | 450 | 406 | 433 | 64.0 | 80.0 |
FR55-T threaded connection type external dimensions

FR55-T external dimensions thread type
Size (mm) | End face size L (mm) | Outer diameter of the body A (mm) | thread specification | Height H (mm) |
4 | 50 | 36 | M30*1.5 | 109 |
6 | 50 | 36 | M30*1.5 | 109 |
10 | 50 | 36 | M30*1.5 | 109 |
15 | 75 | 40 | G1 | 113 |
20 | 85 | 44 | G1 | 117 |
25 | 100 | 52 | G1-1/4 | 125 |
32 | 120 | 58 | G1-1/2 | 131 |
40 | 140 | 69 | G2 | 142 |
50 | 150 | 81 | G2-1/2 | 154 |
FR55-C clamp connection type external dimensions
FR55-C external dimensions clamp connection
Size (mm) | End face size L (mm) | Outer diameter of the body A (mm) | thread specification | Height H (mm) |
15 | 75 | 51 | 51 | 124 |
20 | 80 | 51 | 51 | 124 |
25 | 100 | 51 | 51 | 124 |
32 | 120 | 51 | 51 | 124 |
40 | 140 | 64 | 64 | 137 |
50 | 150 | 77.5 | 77.5 | 151 |
65 | 175 | 91 | 91 | 164 |
Model Selection Table
FR55- | turbine meter | ||||||||||||||
orifice | |||||||||||||||
DN4 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 (special pipe diameters such as DN300 are agreed upon for delivery) | |||||||||||||||
output signal | |||||||||||||||
Pulse+4 to 20mA current signal | |||||||||||||||
Pulse+0 to 5V voltage signal | |||||||||||||||
High point low point normally open contact signal (switch value full range setting) | |||||||||||||||
Connection method | |||||||||||||||
Threaded sealed connection | |||||||||||||||
Flange connection | |||||||||||||||
Quick sealing hose connector | |||||||||||||||
Sanitary grade clamp connection | |||||||||||||||
accuracy | |||||||||||||||
Accuracy 0.2% (applicable to pipelines above DN15) | |||||||||||||||
Accuracy 0.5% (applicable to pipelines above DN10) | |||||||||||||||
Accuracy 1.0% | |||||||||||||||
Material of the liquid receiving body | |||||||||||||||
Stainless steel 1.4301 (304) | |||||||||||||||
Stainless steel 1.4435 (316L) | |||||||||||||||
Voltage resistance level | |||||||||||||||
EN 1092-1(DIN) PN10 | ASME B16.5(ANSI)CLASS150 | ||||||||||||||
EN 1092-1(DIN) PN16 | ASME B16.5(ANSI)CLASS300 | ||||||||||||||
EN 1092-1(DIN) PN25 | ASME B16.5(ANSI)CLASS600 | ||||||||||||||
EN 1092-1(DIN) PN40 | ASME B16.5(ANSI)CLASS900 | ||||||||||||||
EN 1092-1(DIN) PN63 | ASME B16.5(ANSI)CLASS1500 | ||||||||||||||
EN 1092-1(DIN) PN100 | ASME B16.5(ANSI)CLASS2500 | ||||||||||||||
EN 1092-1(DIN) PN250 | JIS 10K | ||||||||||||||
EN 1092-1(DIN) PN400 | JIS 20K | ||||||||||||||
Special standards for product application areas | |||||||||||||||
System power supply mode | |||||||||||||||
12 to 24V DC | |||||||||||||||
86 to 265V AC | |||||||||||||||
3.6V lithium battery (for pulse signal or display selection only) | |||||||||||||||
BODY MATERIAL | |||||||||||||||
Stainless steel 1.4301 (304) | |||||||||||||||
Stainless steel 1.4435 (316L) | |||||||||||||||
Hastelloy C | |||||||||||||||
Internal impeller and accessory material | |||||||||||||||
430F stainless steel | |||||||||||||||
Stainless steel 1.4435 (316L) | |||||||||||||||
Hastelloy C | |||||||||||||||
Bearing material | |||||||||||||||
Stainless steel 440C ball bearing (non water environment) | |||||||||||||||
Ceramic journal bearings | |||||||||||||||
Graphite journal bearing | |||||||||||||||
Tungsten carbide journal bearing | |||||||||||||||
(Special alternative) VARIO | |||||||||||||||
Customized with special parameters | |||||||||||||||
The above selection table does not include selection codes. If you need selection codes, please contact us or fill in your information |