Jinhu Ouwang Technology Co., Ltd
Home>Products>ECA440A high pressure transmitter
ECA440A high pressure transmitter
Summary: The ECA440A high-pressure transmitter is used to measure gases, liquids, and vapors, and then converts them into a 4-20mADC current signal ou
Product details
summary
ECA440AHigh pressure transmitters are used to measure gases, liquids, and vapors, and then convert them into 4-20mADC current signals for output. The ECA440A can also communicate with the HART275 handheld controller for setting, monitoring, and other purposes.
Functional specifications
output
2-wire system, 4-20mA DC output, digital communication, programmable linear or square root output mode, HART protocol loaded on 4-20mA DC signal.
supply voltage
10.5~42V DC (working state)
10.5-30V DC (intrinsic safety type)
16.4~42V DC (digital communication)
16.4~30V DC (intrinsic safety type)
load
0-1335 Ω working state
250-600 Ω digital communication
HART
Communication Distance
Using multi-core twisted pair cables, the maximum communication distance can reach 1.5km, and the communication distance varies depending on the cable type.
Damping time constant
The sum of damping time constants for amplifier components and membrane enclosures. The damping time constant of amplifier components can be adjusted within the range of 0.2 to 64 seconds
ambient temperature
-40~85℃(-40~185°F)
-30-80 ℃ (-22-176 ° F) [with LCD meter head]
Liquid contact temperature
-40~120℃(-40~248°F)

Performance specifications
Reference accuracy for range adjustment
(Effects of package linearity, hysteresis, and repeatability)
±0.12%
stability
± 0.1% range upper limit/12 months
Pressure transmitter 430A series model and specification code table
model
instrument for drawing circles check take the place of a sign or object indicating number
speak bright
ECA440A
………………………………
High pressure transmitter
output signal
-E……………………………
4~20mA, HART protocol digital communication
Measurement range
(Membrane box)
C……………………………
D……………………………
5~32Mpa(5~320kgf/cm2
5~50Mpa(5~500kgf/cm2
Material of the liquid receiving part
S…………………………
T…………………………
H…………………………
[Body][Membrane box[Exhaust screw
SUS316 SUS316L SUS316
SUS316 TAN SUS316
SUS316 HAS-C SUS316
pipe connection
0………………………
1………………………
2………………………
3………………………
4………………………
5………………………
No process joint (Rcl/4 internal thread on chamber flange)
Process connector with Rcl/4 internal thread
Process connector with Rcl/2 internal thread
Process connector with 1/4NPT internal thread
Process connector with 1/2NPT internal thread
No process joint (1/4NPT internal thread on the chamber flange)
Material of bolts and nuts
A……………………
B……………………
C……………………
[Maximum working pressure
LCapsuleDCapsule
SCM435 32Mpa(320kgf/cm250Mpa(500kgf/cm2
SUS630 32Mpa(320kgf/cm250Mpa(500kgf/cm2
SUH660 32Mpa(320kgf/cm2
Installation method
-2…………………
-3…………………
-6…………………
-7…………………
-8…………………
-9…………………
Vertical installation, high voltage on the right, process connector on top
Vertical installation, high voltage on the right, process connector at the bottom
Vertical installation, high voltage on the left, process connector on top
Vertical installation, high voltage on the left, process connector at the bottom
Horizontal installation, high voltage on the right side
Horizontal installation, high pressure on the left side
electrical interface
0 ………………
2 ………………
3 ………………
4 ………………
5 ………………
7 ………………
8 ………………
9 ………………
G1/2Internal thread, 1 connection port
1/2NPTInternal thread, 2 connection ports
Pg13.5Internal thread, 2 connection ports
M20Internal thread, 2 connection ports
G1/2Internal thread, 2 connection ports with a blind plug
1/2NPTInternal thread, with two electrical interfaces and a blind plug
Pg13.5Internal thread, with two electrical interfaces and a blind plug
M20Internal thread, with two electrical interfaces and a blind plug
Display header
D………………
E………………
F………………
Digital header
Digital header with setting button
(No header)
2-inchPipe installation bracket
A……………
B……………
C……………
D……………
N……………
SECCFlat bracket
SUS304Flat bracket
SECC LType bracket
SUS304 LType bracket
No installation bracket
Additional selection code
/□ Selection specifications
Example: ECA440A-DMS5A-92NN/□
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!