KD-15typedrinking water15Parameter water qualitytestinginstrument
(Select parameters as needed, can be extended)53Item parameters)
1Product Introduction:
PH、 Conductivity is measured using electrodesamount,Turbidity is measured by light scattering or scattering+The transmission principle is used, and other parameters are measured using optical colorimetry,The measurement range is wider and simpler.
This instrument can freely combine parameters such as heavy metals and inorganic salts (including residual chlorine, total chlorine, chlorine dioxide, turbidity, chromaticity, copper, hexavalent chromium, manganese, iron, zinc, aluminum, cyanide, phosphate, sulfate, nitrite, nitrate, ammonia nitrogen, hardness, etc.) according to user needs. Widely applicable for the determination of drinking water, surface water, and ground water.
IIProduct features:
1.When measuring samples, the wavelength is automatically selected without the need for calibration.
2. LCDLarge screen LCD Chinese display, easy and intuitive operation.
3.The instrument is easy to carry and can be used for on-site testing.
4.The optical colorimetric method and electrochemical detection are implemented on the same instrument, and the detection interface is displayed on the same screen.
5.Having data storage capabilitydeleteFunction,Can store curves and have time labelsofdata,The memory used is ferroelectric memory.
6.beltUSBInterfaceAnd the data acquisition software of the upper computer,Can transfer data records to a computer.
7.Cold light source, narrowband interference optical system, good optical stability.
8.Data power-off protection function.It has the function of recording and printing.
9.Rechargeable lithium battery power supply,And it has battery detection function.
10.Imported high-performance turbidity and chromaticity sensors, enablingLow range turbidity and chromaticity measurements are more accurate.
11. Scalable and customizable testing projects.
IIItechnical parameter
1.measuring range、Test project | ||||
15 chemical indicators |
||||
Serial number |
Measurement project |
Measurement range |
Company |
accuracy |
1 |
PH (electrode method), including water temperature |
0-14 |
PH |
±0.05 |
2 |
chroma |
0-500PCU |
PCU |
3% |
3 |
turbidity |
0.00-400.00NTU |
NTU |
2% |
4 |
Aluminum (low)、High range) |
0.01-0.40,0.40-4.00 |
mg/L |
5%(F.S) |
5 |
Iron (low)、High range) |
0.0-5.00,5.0-10.00 |
mg/L |
0.1 or 5% |
6 |
manganese |
0.02-5.00 |
mg/L |
0.05 or 5% |
Manganese (low)、High range) |
0.01-0.10,0.10-1.0 |
mg/L |
5%(F.S) |
|
7 |
Copper (low)、High range) |
0.02-1.0,1.0-10.0 |
mg/L |
5%(F.S) |
8 |
zinc |
0.2-5.0 |
mg/L |
5%(F.S) |
9 |
Chloride ion (chloride) |
0.20-10.0 |
mg/L |
5%(F.S) |
10 |
sulfate |
5.00-200.00 |
mg/L |
5%(F.S) |
11 |
conductivity(Electrode method) |
0.00µs/cm-199.9ms/cm |
ms/cm |
1.0% (F.S) |
12 |
Total hardness (low)、High range) |
0.0-5.0,5.0-200.0 |
mg/L |
5%(F.S) |
13 |
oxygen consumptionCODmn(Manganese method) |
0.00-10.00 |
mg/L |
0.2 or 5% |
14 |
Volatile phenols (low)、High range) |
0.20-5.0,5.0-10.0 |
mg/L |
5%(F.S) |
15 |
Anionic surfactant |
0.01-1.00mg/L |
mg/L |
5%(F.S) |
2..Repeatability:≤3%
3.Optical stability: The absorbance value of the instrument is within20minInternal drift less than0.002A
4.Reading mode: concentration, absorbance, transmittance
5.External dimensions:410mm×300mm×130mm
6.Weight:4kg
4Product Configuration Checklist:
host1Common parameters for table and reagent preparation10Set, colorimetric tube10Zhi, colorimetric dish2Only,
Portable case1One,USBLine1Root, data collection installation CD1One, charging power supply1One,
an instruction manual1Copy, Product Qualification Certificate1Copy and warranty card1Share.