Double machine cascade refrigeration unit
This product is suitable for various industries such as chemical, mechanical, pharmaceutical, etc. that require low-temperature refrigerant as a refri
Product details
The RX (FD) series cascade refrigeration unit is designed to provide users with low-temperature refrigerant for cyclic use from -35 ℃ to -80 ℃.
This product is suitable for various industries such as chemical, mechanical, pharmaceutical, etc. that require low-temperature refrigerant as a refrigerant.
1. Compressor: Adopting Bock imported from Germany Bitzer has stable performance and low failure rate. Refrigerant: Low temperature environmentally friendly refrigerant R404A/R23
2. Siemens industrial grade PLC+color LCD touch screen control system from Germany, with high degree of automation and precise control without human monitoring. Can meet the 24-hour continuous production demand.
3. Convenience: The unit adopts advanced PLC control technology, achieving one click startup and fully automatic operation. We can also achieve multi machine linkage and remote control according to your requirements.
4. The refrigeration unit has been fully debugged and qualified before leaving the factory. Users only need to connect the water source and power supply to use it.
PRODUCT MODEL
project
unit
RXH35D(FD)
RXH40D(FD)
RXH45D(FD)
RXG54D(FD)
RXG75D(FD)
RXG98D(FD)
Refrigerant temperature/cooling capacity
-45℃~-50℃
kW
29.7
34
38.5
45.9
54.1
83.4
-55℃~-60℃
19.2
22.1
25.3
32.2
44.37
58.2
-65℃~-70℃
11.5
14.8
16.5
20.6
33.6
37.8
power supply
Distribution power
kW
33
43
50
68
88
102
Primary compressor
Operating power
kW
17.7
19.4
23
35.9
45.6
51
refrigerant
start mode
Partial coil startup
Secondary compressor
Operating power
kW
16.35
19.2
21.1
25.2
33.2
41.6
refrigerant
start mode
evaporator condenser
type
evaporator
type
Refrigerant flow rate
m³/h
12.7
14.6
16.5
19.7
23.2
35.7
condenser
type
discharge
m³/h
10.9
12.4
14.2
18.3
22.8
30.2
Refrigerant control
expansion valve
Safety protection device
 
Take over specifications
condenser
mm
DN40
DN50
DN50
DN65
DN65
DN80
evaporator
mm
DN50
DN50
DN65
DN65
DN80
DN80
External dimensions
Long (L)
mm
2000
2200
2400
2600
2800
3000
Width (W)
mm
1000
1000
1100
1100
1200
1200
High (H)
mm
1650
1700
1700
1750
1750
1800
weight
net weight
kg
870
1053
1323
1695
1860
2280
Operating weight
kg
957
1158
1455
1865
2046
2508
PRODUCT MODEL
project
unit
RXG106D(FD)
RXG130D(FD)
RXG143D(FD)
RXG168D(FD)
RXG178D(FD)
RXG195D(FD)
RXG211D(FD)
RXG232D(FD)
Refrigerant temperature/cooling capacity
-45℃~-50℃
kW
90.8
110.7
121.5
143.2
151.2
165.4
179.1
197.2
-55℃~-60℃
63.4
77.3
84.8
99.9
105.6
115.5
125.2
137.7
-65℃~-70℃
40.8
49.8
54.6
64.3
68.2
71.8
80.6
88.6
power supply
3φ-380V-50Hz
Distribution power
kW
113
128
148
158
168
188
208
238
Primary compressor
Operating power
kW
59.7
67.1
76.4
80.3
88.3
96.1
105.2
124.3
refrigerant
R404a
start mode
Y - △ Start
Secondary compressor
Operating power
kW
45.6
55.6
60.5
68.2
71.7
78.9
86.1
95.7
refrigerant
R23
start mode
Y - △ Start
evaporator condenser
type
plate heat exchanger
evaporator
type
Refrigerant flow rate
m³/h
38.9
47.4
52.1
61.4
64.8
70.9
76.8
84.5
condenser
type
shell and tube heat exchanger
discharge
m³/h
33.6
40.0
44.3
50.0
53.3
58.4
63.5
71.5
Refrigerant control
expansion valve
Temperature sensitive external pressure equalization thermal expansion valve/electronic expansion valve
Safety protection device
 
High and low voltage protection, anti freezing, anti heat, dual protection, safety valve, overload protection, phase loss, reverse phase, undervoltage, overvoltage, water flow protection, etc
Take over specifications
condenser
mm
DN80
DN80
DN80
DN100
DN100
DN100
DN100
DN100
evaporator
mm
DN80
DN100
DN100
DN100
DN100
DN100
DN100
DN100
External dimensions
Long (L)
mm
3200
3400
3600
3800
3800
4000
4100
4200
Width (W)
mm
1300
1400
1500
1500
1500
1600
1600
1800
High (H)
mm
1850
1900
1900
2000
2000
2100
2100
2200
weight
net weight
kg
2880
3285
3480
3540
3600
3780
4140
4650
Operating weight
kg
3168
3614
3828
3894
3960
4158
4554
5115
Note:
1. The cooling capacity is measured under the following temperature conditions: the refrigerant is alcohol; The inlet/outlet temperature of the cooling water is 32/37 ℃.
2. Scope of work:
The outlet temperature of the cooling water is between 22 ℃ and 37 ℃
The temperature difference at the inlet of the cooling water ranges from 3.5 ℃ to 10 ℃
The outlet temperature of the frozen liquid is -40 ℃ to -80 ℃
The temperature difference between the inlet and outlet of the refrigerant is 2.5 ℃ to 10 ℃
3. Paired cooling water and refrigerant inlet and outlet connecting flanges are provided at the factory, and the refrigerant (alcohol) is provided by the user.
4. If there are any changes to the above specifications without prior notice, this will help our company to bring the latest technological achievements to customers at any time.