The ChannelMaster type horizontal acoustic Doppler current profiler (referred to as CM type H-ADCP) is a new generation ADCP product from RDI company. It has a compact structure, high standard configuration, strong functionality, and a wide range of applications.
The main features of ChannelMaster type H-ADCP are:
Adopting RDI's broadband patented technology.
High precision, high spatial and temporal resolution. Smaller units can be used
Obtain accurate flow velocity data within a shorter sampling time step.
High quality test data can also be obtained for low flow rates and unsteady flows that are difficult to test.
Standard configuration: 1-128 optional units, 0.1-10 m optional unit length, 1
-300 m profile range (depending on system frequency). You can get more
Flow rate data has great flexibility.
Standard configuration includes ultrasonic water level gauge and pressure type water level gauge.
• Standard configuration inclinometer. Tiltmeter for adjusting H-ADCP installation bracket and monitoring
The tilt variation of the installation bracket plays an important role in ensuring the quality of test data.
Standard stainless steel mounting base makes H-ADCP installation very convenient.
Throughout its more than 20 years of development, RDI has always been at the forefront of ADCP technology
Leading position. RDI company has passed ISO9001 international quality system certification.
Application of H-ADCP:
Real time measurement of flow velocity and flow rate at river hydrological or hydrological stations (using indicator flow rate method or numerical method to calculate flow rate)
Real time measurement of open channel flow velocity and flow rate
Real time measurement of irrigation channel flow velocity and flow rate
Real time monitoring of the total amount of river water quality monitoring stations
Collect flow field data in river and estuary areas to provide calibration or validation data for flow field numerical models.
Real time monitoring of the flow field in port waters provides flow velocity data to ensure the safety of incoming and outgoing ships.
Real time monitoring of flow field near offshore oil platforms
ChannelMaster type H-ADCP technical specifications
Flow velocity profile measurement (broadband patented technology):
System frequency 300kHz, 600 kHz, 1200 kHz
Unit number 1-128 1-128 1-128
Minimum unit length (m) 1 0.5 0.1
Maximum unit length (m) 10 8 4
Maximum cross-sectional range (m) 300 90 20
1st unit starting point (m) 2-10 1-10 0.3-10
Flow velocity range (m/s) ± 5 ± 5 ± 5
Accuracy ± 0.5% ± 0.5% ± 0.5%
±0.2cm/s ±0.2cm/s ±0.2cm/s
Resolution (mm/s) 1 1
Note: The maximum profile range depends on parameters such as temperature, salinity, and sediment concentration.
Standard configuration sensor:
Flow velocity measurement transducer: configuration: dual beam, ± 20 º beam angle
Beam width: 1200kHz/600kHz: 1.5 º
300kHz:2.2º
Ultrasonic water level gauge: Range: 0.1-10 m
Accuracy: ± 2 mm
resolving power: 0.1 mm
Pressure type water level gauge: Range: 0.1-10 m
Accuracy: ± 2 mm
resolving power: 1.0 mm
Temperature probe: Range:- 4º to 35ºC
Accuracy: ±0.2ºC
resolving power: 0.01º C
Tiltmeter: Range: ± 15º
Accuracy: ±0.5º
resolving power: 0.01º
Communication: RS-232、RS-422、RS-485、SDI-12
• Supports SDI-12 v 1.3
• Simultaneously supports RS-232 SDI-12、 Memory recording
Baud rate: 300-115,200 bps
Memory: 2 MB
Software: Data collection and playback: WinHADCP
System detection: BBTalk
Shell: Polyurethane cast shell, titanium alloy connector
Base: Stainless steel installation base
Power supply: Voltage: 9-18 VDC
Maximum current: 1.5A
Note: Power consumption depends on the flow rate measurement parameter settings. Contact RDI company.
Weight:
System frequency 300kHz, 600kHz, 1200kHz
Weight in air (kg) 6.80 4.76 3.40
Weight in water (kg) 3.17 2.00 1.58
Dimensions (horizontal installation):
System frequency 300kHz, 600kHz, 1200kHz
Height (cm) 18.3 18.3 18.3
Width (cm) 32.5 26.4 18.3
Depth (cm) 19.8 19.3 18.9
Homework temperature:- 5º to 45ºC
Storage temperature:- 30º to 75ºC