Firstly, why choose a bottle washing machine?
Traditional manual cleaning
|
Bottle washing machine cleaning
|
Toxic chemicals and solvents can cause harm to the health of laboratory personnel, even irreversible damage for life.
|
Thoroughly clean and disinfect to avoid direct contact of harmful substances with the human body and minimize potential damage. Reduce labor intensity and lower the incidence of occupational diseases.
|
It is difficult to thoroughly clean, requires a lot of manual labor for cleaning, uses a large amount of cleaning agents, and has a high cost.
|
One machine for cleaning, disinfection, and drying replaces manual labor, reduces labor costs, simplifies workflow, and reduces investment in other equipment.
|
Glassware is prone to breakage and has a high bottle breakage rate during manual cleaning.
|
Fully automatic intelligent cleaning extends the service life of glass containers. Continuous flushing in all directions is much more effective than manual or ultrasonic cleaning.
|
The cleaning results are difficult to reproduce
|
Implement standardized cleaning of items to avoid unreliable and inconsistent manual cleaning effects that may affect experimental results;
|
Secondly, an introduction to the SPCC series bottle washing machine with spectral labels (1) Cleaning and disinfection standards:BS EN ISO 15883The medical cleaning and disinfection standards can meet the decontamination requirements of the vast majority of laboratory glassware.
(2) Customer groups used: third-party testing, organic chemicals, petrochemicals, pharmaceuticals, medical, food, disease control centers, fiber testing bureaus, etc.
(3) Scope of cleaning items: test tubes, pipettes, culture dishes, conical flasks, volumetric flasks, beakers, and other necessary glass and metal vessels.
(4) Humanized programming:
Program Name
|
Scope of application
|
Time (min)
|
Standard cleaning procedure |
Cleaning of general contaminated vessels |
60 minutes |
Quick cleaning program |
Cleaning of mildly contaminated vessels |
30 Minutes |
Custom Program
|
Set cleaning parameters for vessels with different levels of pollution on your own
|
Free to set
|
Self cleaning program
|
Periodic descaling treatment of cleaning chambers and pipelines
|
30 Minutes
|
Drying Procedure
|
Use separately for drying vessels
|
1-99 free setting
|
(5) Optional models:
model
|
Dimensions (W * D * H) mm
|
Voltage (V/Hz)
|
Power (KW)
|
Effective volume (L)
|
Water consumption/circulation (L)
|
Noise (dBa)
|
Inlet pressure (Mpa)
|
SPCC-120E (Desktop)
|
980*740*830
|
220/50~60
|
6
|
120
|
10
|
≤50
|
0.3-0.8
|
SPCC-220E (Vertical)
|
710*680*1750
|
380/50~60
|
17
|
220
|
15
|
≤55
|
0.3-0.8
|
SPCC-320E (Vertical)
|
710*680*1900
|
380/50~60
|
19
|
320
|
18
|
≤55
|
0.3-0.8
|
SPCC-420E (Vertical)
|
1100*900*2000
|
380/50~60
|
22
|
420
|
25
|
≤60
|
0.3-0.8
|
Third: Detailed Introduction to the Functions of SPCC Series Bottle Washing Machine with Spectral Labels (Part)
performance index
|
performance parameter
|
advantage
|
heating system
|
According to the requirements of the cleaning items and the different requirements of the cleaning process, the circulating water in the cleaning compartment can be automatically heated to achieve the most suitable cleaning temperature. |
Such as initial rinsing with low temperature water, washing with warm water at 45 ℃ (where the activity of cleaning enzymes is strongest), disinfecting with hot water at 93 ℃, and drying with hot air at a maximum temperature of 110 ℃.(Program adjustable)
|
heating power
|
5KW (for 120L) 15KW (for 120L and above) |
15KW water heating, with a heating temperature of 6.5 ℃ per minute,Shorten the water heating time, thereby shortening the overall cleaning time;
|
Circulating pump (maximum flow rate)
|
800L/min
|
The pump has a large flow rate, fast water circulation speed, and high pressure,The cleaning effect is better than that of a general circulation pump. |
Cleaning program (factory preset reference)
|
5 programs:
Standard program, quick wash program, drying program, self-cleaning program, custom program.
|
PLC control system,The number of program groups can be freely groupedUsers can combine and adjust programs at any time according to cleaning requirements, and develop multiple programs to reflect the concept of humanized design.
|
Soft water function
|
Optional features
|
The instrument has two inlet channels, one for tap water and the other for pure water, and does not require a soft water function. Usually, to ensure the final cleaning effect, it is required to rinse with pure water.
|
Number of peristaltic pumps
|
Two of them
|
The unique dual pump structure and dual stainless steel filter screen for automatic sewage discharge separate stains and automatically eliminate them; Dual pump design: one for cleaning and one for discharge to reduce the possibility of cross contamination.
|
Main control system
|
PLC control system
|
(1) PLC is an industrial grade control component with stability, long lifespan, temperature and moisture resistance, and no electromagnetic radiation interference from other precision instruments; (2) Microcontrollers, commonly known as computer boards, have the biggest drawback of being greatly affected by environmental temperature and humidity. Compared to PLCs, they are more susceptible to damage and may cause electromagnetic interference to high-precision equipment;
|
control panel
|
Color LCD touch screen
|
High end and high-end, concise, convenient and easy to operate. The display screen has a USB interface: (1) Easy to read and store data in EXCEL format, making it convenient for customers to extract and use information;
(2) Multiple levels of password management permissions can be added;
|
Operation security protection (Automatic fault diagnosis program, buzzer automatically alarms. When the instrument malfunctions, the screen will display fault information, indicating the location of the problem and facilitating maintenance by engineers. The instrument also provides warning information to prompt users to handle it in a timely manner.)
|
(1) Electronic safety lock (2) Inlet flow (cleaning agent) quantity control system (3) Overflow protection (4) Dual temperature monitoring system
|
(1) If the door lock is not in place, there will be an alarm prompt and the machine cannot operate; (2) 1-999ml can be freely added with a precision of 1ml, extremely precise. (3) PLC monitoring for overflow, no need for drip tray assistance. (4) Dual temperature control, monitoring the water temperature in the cleaning chamber and circulation pipeline separately. It can be heated up to 100 ℃ or below, and users can set it according to their needs with an accuracy of 1 ℃.
|
texture of material
|
(1) Internal cavity material (2) Shell material (3) Inner cavity insulation (4) Door body
|
(1) The inner cavity is made of 316 mirror polished stainless steel, which is heat-resistant, corrosion-resistant, and easy to clean. (2) The shell material is high-quality 304 stainless steel. (3)The internal insulation is made of high-quality thermoacoustic materials, which can reduce heat loss and electricity consumptionLow noise design, with a minimum noise level below 50dB. (4) The door is made of 304 stainless steel frame and tempered glass window.Users can observe the cleaning status of internal containers during device operation and stay informed of the cleaning progress at any time.
|
Cleaning rack
|
(1) Standard cleaning rack:
Suitable for cleaning test tubes, beakers, measuring cylinders, triangular bottles, etc. Using a triangular bracket, it can be positioned at any height on the cleaning column to accommodate vessels of different heights. There are three heights for the cleaning column: 90mm, 140mm, and 220mm. (2) Cone bottle cleaning rack:
Using a curved bracket, it can be positioned at any height on the cleaning column to accommodate vessels of different heights. (3) Wide mouth bottle cleaning rack:
Size of the area where containers can be placed: 560 * 510mm; Suitable for cleaning pipettes, burettes, etc.
(4) Culture dish cleaning rack:
Culture dishes with a diameter greater than 60mm can be placed, among which a single layer of 90mm culture dishes can hold 45 sets (bottom+cover), and up to 4 layers of cleaning racks can be placed;
|
All cleaning racks can be completely disassembled for easy cleaning of the rack piping.
|
Cleaning volume
|
Taking SPCC-220E as an example, it can clean 112 pieces per 100ml.
|
This is just using commonly used specifications to define the quantity of cleaning per cycle,Currently, the SPCC series has the highest number of cleaning tasks. |
For more product details, please feel free to contact our sales staff. We will be dedicated to serving you! |
When buying a bottle washing machine, SPCC is the first choice!
Recommended by Guangdong Federation of Science and Technology Laboratories!Credit guarantee, reliable quality!
Our sales engineering team has eight years of technical service experience, so you have no worries!