Detu testo316-3 refrigerant leak detector (refrigerant leak detector)Can detect CFC, HCFCs, HFC refrigerants, including sensors, instrument boxes, factory reports, batteries, spare filters, and operation manuals.
high sensitivity
The small leak detection sensitivity is 4 g/a (grams per year), which complies with SAE J1627/EN 14624 regulations and also meets F-GAS (fluorinated gas) related regulations. Testo 316-3 can effectively assist users in complying with relevant regulatory requirements for their refrigeration systems.
Automatic zeroing, easy to operate
The zero adjustment function of testo 316-3 effectively eliminates the interference of environmental background factors, and can accurately detect leaks even in environments contaminated with gas or other refrigerants. At the same time, the instrument can be operated with just one click, without the need for pre settings, and can be turned on to start testing.
LED sound and light alarm
The five level graded LED indicator light quickly and real-time indicates the leakage point and the leakage amount. It can also provide sound alarm for customers to use in situations where LED display cannot be observed.
Sensors can be replaced by themselves
Detu testo316-3 refrigerant leak detector (refrigerant leak detector)Using a "heated diode" to ensure a service life of 80-100 hours. Customers can replace the sensors themselves to ensure that the sensitivity of the refrigerant leak detector remains in good condition.
Detu testo316-3 refrigerant leak detector (refrigerant leak detector)List of advantages:
Leak detection sensitivity 4 g/a (g/year)
Leak detection applicable to all commonly used refrigerants
One click operation, no preset required, start detection immediately upon startup
LED indicator light, quickly and clearly detect leakage points and their sizes
Automatic zeroing function effectively eliminates interference from environmental background factors
Compliant with SAE J1627/EN 14624 regulations
Users can replace the sensor themselves
Detu testo316-3 refrigerant leak detector (refrigerant leak detector)
Technical Parameter | |
sensitivity | 4g/a (grams per year) |
Detectable refrigerant | R22, R134a, R-404A, R-410A, R507, R438, as well as all CFCs, HFCs, and HCFCs |
Compliance with regulations | SAE J1627、EN14624、EG 2004/108/EG |
call the police | LED and sound alarm |
operate temperature | - 20 ~ 50°C |
Operating humidity | 20 ~ 80%RH |
storage temperature | 0 ~ 50°C |
power supply | Two D-type No.1 batteries |
storage temperature | 0 ~ 50°C |
power supply | Two D-type No.1 batteries |
BATTERY LIFE | Continuous use for 16 hours |
Sensor lifespan | 80~100 hours |
weight |
About 500g (including battery) |