Curie point blowing capture thermal desorption instrument JTD-505 Ⅲ/JTD-505M Ⅲ
Curie point blowing capture thermal desorption instrument JTD-505 Ⅲ/JTD-505M Ⅲ
Product details
Instrument Introduction

Realize device miniaturization! Up to 48 samples can be tested continuously!
The new model maintains the highly acclaimed Curie point rapid heating method of JTD-505 II and successfully achieves miniaturization of the equipment. With the miniaturization of equipment, the installation and disassembly of instruments have become more convenient, and the installation space has become more abundant.


On the other hand, the equipment continues the characteristics of JTD-505 II, using PAT tubes that can directly place electronic components and polymer samples for analysis. It can complete gas analysis such as indoor and clean room gases, environmental trace analysis, and thermal decomposition devices for gases generated by electronic products.


In addition, this device can be used in conjunction with peripheral products such as PAT burning devices and various degassing collection devices to complete the analysis of all volatile components.

main features

1. It is possible to set 1 to 15+α=any number of samples from a maximum of 48 samples at a time, achieving unmanned operation in conjunction with TD-GC/MS.
On the PAT sampler, a maximum of 15 PAT tubes can be loaded at a time, but continuous analysis of up to 48 experiments can be achieved through programming. For example, conducting repeated analysis of the same PAT, inserting and replacing PAT midway, and analyzing up to 48 samples.
<Effective Analysis Case>
1) To confirm whether the contamination between samples has been removed, blank tests need to be conducted arbitrarily.
2) For a sample, multiple desorption temperatures need to be continuously analyzed.
2. It can achieve a wide range and high sensitivity analysis from low boiling point components to high boiling point components.
3. By using the unique Curie point heating method, clearer spectra can be obtained.
4. Using the industry's largest PAT tube (sample tube), it can capture a large amount of atmospheric samples
5. Due to the use of the industry's largest PAT tube (sample tube), small samples and granular materials can be directly placed into the sample tube for volatile component analysis. (Internal volume: 10ml, inner diameter 12mm. Height within 50mm)
6. The device is equipped with a highly effective separation mode for direct sample import, which can be combined with effective methods for volatile gas analysis of samples or granular materials after direct heating.
(To remove the gas continuously generated from the sample, a clean blank sample tube can be used to replace it, so that there will be no residual memory peaks in the next sample.)
7. Adopting a two-stage flow separation method, even samples with large degassing volumes can be introduced into chromatography for analysis without worrying about contaminating the chromatography.
8. Archive and save analysis conditions to achieve high repeatability analysis. 16 analysis conditions can be classified and saved for easy access to settings.
9. The usage of liquid nitrogen can be determined through a liquid nitrogen flowmeter.
10. The latest 48 analysis results can be classified and saved for easy comparison of results.
11. Regardless of the type of GC or GC/MS used domestically or internationally.

Technical Parameter

JTD-505Ⅲ

JTD-505MⅢ

Host

PAT heated withdrawal device

-99 ℃~350 ℃ (resistance heating)

Transmission pipeline

Room temperature+10 ℃~300 ℃ (resistance heating), metal capillary tube

SAT heating and desorption device

Curie point heating method (standard: 280 ℃)

SAT

Quartz tube (for hot foil filling) containing Tenax filler

SAT cooling

To -99 ℃ (liquid nitrogen cooling)

SAT heating furnace

200 ℃ (resistance heating)

syringe

Room temperature+10 ℃~300 ℃ (resistance heating)

GC connection method

Connect directly to the chromatographic column or connect using an injection needle

Size and weight

355(W)×210(H)×130(D) mm・3.1 Kg

Sample injector

PAT rack

Load a maximum of 15+1 PAT units

——

Conveyor Drive

Motor driven

——

PAT import plunger

Air pressure 0.5MPa

——

Size and weight

215 (W) × 250 (H) × 763 (D) mm · 14.5 Kg

——

Control device

Touch button

Set the temperature, flow rate, valve switching, etc. of each device

Size and weight

350(W)×250(H)×500(D) mm・14 Kg

power supply

AC100 V, 50/60 Hz, 15 A (universal interface is 8A)

RF power supply

High frequency power supply

600 KHz、48 W

Built in device

Built in shunt valve and transformer

Size, power supply

350(W)×180(H)×500(D) mm・15 Kg

Liquid nitrogen vacuum bottle and siphon tube

Liquid nitrogen vacuum bottle

Capacity 50 L (siphon type)

Volume 20 L (siphon type)

Size and weight

(Outer diameter) 460 mm × (H) 930 mm · 24.8 Kg

(Outer diameter) 460 mm × (H) 930 mm · 24.8 Kg

siphon

1000mm long (1300mm when extracted from siphon bottle), equipped with solenoid valve and pressure safety valve

Standard attachments

PAT (Tenax GR filling)

5 pieces

1 unit

PAT (empty)

3 pieces

1 unit

PAT clamp

16 of them

——

PAT manual clamp

1 piece

2 pieces

PAT cover

16 of them

——

Needle heater

1 set

GC adapter

1 set

cable

1 set

Piping

1 set

tool

1 set

Operating Instructions

1 volume

Sample injection component

1 set

Optional anti overheating device

temperature sensor

4 of them

power supply

15A、 Induction current 30mA, equipped with emergency stop switch

Size and quality

350(W)×500(D)×170(H )mm・8 Kg