Composite salt spray test chamber | Salt spray constant temperature and humidity composite test
Composite salt spray test chamber | Salt spray constant temperature and humidity composite test
Product details
product name
Salt spray composite test chamber/Salt spray constant temperature and humidity composite test chamber
application
The salt spray composite test chamber has been upgraded and installed on the traditional corrosion chamber, which can support salt spray corrosion, humidity (high temperature and high humidity, low temperature and low humidity), air drying (hot drying, air drying) and other tests simultaneously.
Box Structure
The salt spray composite test chamber is integrally molded and welded at high temperatures, corrosion-resistant, easy to clean, and leak free.
The design of a super large saltwater tank eliminates interruptions in testing due to a lack of saltwater.
The salt spray test box adopts a water sealed structure between the box cover and the box body, without salt spray overflow.
The circuit control system is fixed in a location that is easy to inspect and maintain, and adopts a door lock opening edge cover door.
The tower spray system is equipped with a salt liquid filtration system, without a crystallization nozzle, the salt spray is evenly distributed, and the sedimentation is freely adjusted.
control system
The salt spray composite test chamber adopts the "Youyi Control" brand temperature and humidity instrument imported from Japan, with a 7-inch high-definition true color LCD touch display screen.
The controller operation interface is available in both Chinese and English, and the real-time operation curve chart can be displayed on the screen.
It has a capacity of 1000 program segments, each segment can cycle 999 steps, with a maximum time setting of 99 hours and 59 minutes per segment, and 10 sets of program linking functions.
The controller panel comes standard with a 10M/100M Ethernet interface, which automatically obtains IP addresses for remote control. It supports real-time monitoring, historical curve playback, program editing, FTP upload and download, historical fault viewing, remote setting/program control, and other functions.
Composite testing method
a、 neutralisation test
Laboratory: 35 ℃± 2 ℃ Saturated air tank: 47 ℃± 2 ℃
b、 acid test
Laboratory: 50 ℃± 2 ℃ Saturated air tank: 63 ℃± 2 ℃
c、 Moisture test
Laboratory: 40 ℃± 2 ℃, relative humidity 90%~95% R • H (equipment can meet the set temperature up to 60 ℃, relative humidity up to 98% R • H)
Heating is achieved through an inner tank style heating and humidification method, which heats up quickly and distributes temperature and humidity evenly
Saturated air tank adopts automatic water replenishing. After continuous spray for about 20 hours, water replenishing will begin. After 1-2 minutes, water replenishing will end and spray will continue
d、 Drying test
Drying treatment is carried out using a blower fan, and the specimen is dried for 24 hours under standard atmospheric conditions of temperature (15 ℃~35 ℃) and relative humidity not exceeding 50%
Compliant with standards
TSH1555G, TSH3131G Appearance Coating Quality, ASTMB-117, GB/T2423.17-2008, GB/T 2423.18-2000 "Basic Code for Electrical and Electronic Products - Test Ka", Salt Spray Test Method and GB/T10125-1997、GB/T10587-2006、GB10593.2-1990、GB/T1765-1979、GB/T1771-2007、GB/T12967.3-2008、GB/T5170.8-2008 And equivalent relevant standards such as IEC, MIL, DIN, etc



model
YWX/F-150
YWX/F-250
YWX/F-750
YWX/F-010
YWX/F-020
Studio size D × W × H (mm)
450×600×400
600×900×500
750×1100×500
850×1300×600
900×2000×600
Dimensions D × W × H (mm)
700×1200×1100
950×1500×1200
1100×1700×1250
1150×2100×1550
1250×2800×1600
power
1.3(kw)
1.5(kw)
2.3(kw)
4.5(kw)
6.5(kw)
performance index
temperature range
Room temperature+5 ℃~60 ℃
Humidity range
30~98%RH
temperature uniformity
±2℃
temperature fluctuation
±0.5℃
Salt spray deposition amount
1~2ml/80cm²·h
spray mode
Choose between continuous and periodic options
Temperature and humidity operation control system
temperature control
Imported programmable touch LCD with Chinese English dialogue display Microcomputer integrated controller
temperature sensor
Platinum resistance PT100Ω/MV
Heating system
Fully independent system, nickel chromium alloy electric heating heater
Spraying Systems
Tower spray device with non crystallization nozzle (finer and evenly distributed particles)
spray time
1~9999 (SMH) and adjustable cycle
Salt collection
Equipped with standard funnel and standard measuring cylinder
Salt liquid filtration
Install a water quality filter at the suction tube (to prevent nozzle blockage and terminate the test)
Preheating of salt solution
The temperature of the salt solution is balanced with the temperature inside the box (so that the low temperature of the salt solution does not affect the test temperature)
Standard configuration
1 round rod, 1 V-shaped sample holder, 2 nozzles, 2 funnels, and 2 sets of measuring cylinders
Safety protection
Leakage, short circuit, overheating, water shortage, end of test, overcurrent protection
supply voltage
AC220V±10% 50Hz / AC380V±10% 50Hz
Environmental temperature for use
5℃~+30℃ ≤85%RH
seal
Adopting a water sealed structure, there is no salt spray overflow
Note: Wet heat test or salt spray test can be conducted separately
Customizable according to user needsLarge walk-in salt spray laboratory
This technical information is subject to change without prior notice