Shanghai Huile Electric Co., Ltd
Home>Products>Chinese LCD three-phase multifunction meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1881753568318321031365
  • Address
    No. 95 Shihuxin Road, Shihudang Town, Songjiang District, Shanghai
Contact Now
Chinese LCD three-phase multifunction meter
Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure elec
Product details
  • Chinese LCD three-phase multifunction meter
  • Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input and output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.



    Detailed Introduction


    summary
    Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input and output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.
    TECHNICAL INDEX
    transport
    enter
    measure
    measure
    apparent
    show
    electricity
    press
    RATING AC100V, 400V (please specify when ordering)
    overload Duration: 1.2 times Instantaneous: 2 times/10 seconds
    power consumption < 1VA (per phase)
    impedance >500KΩ
    accuracy RMS measurement, accuracy level 0.5
    electricity
    flow
    RATING AC 1A, 5A (please specify when ordering)
    overload Duration: 1.2 times Instantaneous: 10 times/10 seconds
    power consumption < 0.4VA (per phase)
    impedance <2MΩ
    accuracy RMS measurement, accuracy level 0.5
    frequency 45-55Hz, accuracy 0.01 Hz
    power Active power accuracy level 0.5, reactive power accuracy level 1.0
    electric energy Active power accuracy level 1.0, reactive power accuracy level 2.0
    display Programmable, switchable, looping (LED/LCD) display
    Electric energy display range 0.01-KWh (or KVar)
    power supply scope of work AC/DC 80-270V special requirements can be customized
    power consumption <5VA
    input Switching input 4-channel switch input, remote dry contact mode (optional)
    output Digital Interface RS-485, MODBUS-RTU protocol (optional)
    pulse output 2-channel power pulse output (optional)
    Switching Output 4-channel switch output, relay passive contact mode (optional)
    analog output 4-channel analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional)
    environment work environment -10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m
    Environment -55-85 ℃, relative humidity<85%
    secure pressure resistance Input/power>2KV, input/output>2KV, power/output>1KV
    isolation Input, output, and power supply to the chassis>100M Ω


    List of multifunctional power meter models and functions
    model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
    A B C D E digital communication Switch Module Transmission output electric energy pulse
    HL-42K3E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    120 120 83 112 112 RS-485
    MODBUS
    -RTU
    4-way entry
    Route 4 departs
    4DI/4DO
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    2-channel electrical energy
    pulse output
    HL-42K3EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 120 120 83 112 112
    HL-96K3E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    98 98 83 90 90 RS-485
    MODBUS
    -RTU
    4-way entry
    Route 4 departs
    4DI/4DO
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    2-channel electrical energy
    pulse output
    HL-96K3EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 98 98 83 90 90
    HL-80K3E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    84 84 83 76 76 RS-485
    MODBUS
    -RTU
    2-channel switch
    Quantity output or
    2-channel electrical energy
    pulse output
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    2-channel switch
    Quantity output or
    2-channel electrical energy
    pulse output
    HL-80K3EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 84 84 83 76 76
    HL-72K3E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    75 75 90 67 67 RS-485
    MODBUS
    -RTU
    2-channel switch
    Quantity output or
    2-channel electrical energy
    pulse output
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    2-channel switch
    Quantity output or
    2-channel electrical energy
    pulse output
    HL-72K3EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 75 75 90 67 67

    Wiring example diagram

    Note: 1 "★" is the current input terminal. Please refer to the product's random wiring diagram for specific wiring methods and parameters.
    Order List
    When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
    Example 1: Model: HL-42K3E Power Supply: AC220V Input: 10KV/100V 200A/5A Power Network: Three phase three wire
    Communication: RS485/MODBUA-RTU Function Expansion: 4DI/4DO Quantity: 88 units


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!