Dongguan Haotian Testing Equipment Co., Ltd
Home>Products>Characteristics of identifiable high-temperature moist heat oven products
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15899907907
  • Address
    Building 2, No. 25 Yuanxia Road, Changping Town, Dongguan City
Contact Now
Characteristics of identifiable high-temperature moist heat oven products
The high temperature test chamber is an essential testing equipment in fields such as aviation, automotive, home appliances, and scientific research.
Product details

Purpose of high temperature test chamber:

High temperature test chamber is an essential testing equipment in aviation, automotive, home appliances, scientific research and other fields, used to test and determine the temperature environment changes or parameters and performance of electrical, electronic and other products and materials for high temperature or constant testing.

model: ST-512


Programmable battery explosion-proof testing equipment

High temperature test chamber is an essential testing equipment in the fields of aviation, automotive, home appliances, scientific research, etc. It is used to test and determine the parameters and performance of electrical, electronic, and other products and materials after high-temperature or constant temperature environmental changes. Programmable battery explosion-proof testing equipment


This product is suitable for testing according to the national standard GB/T2423.2 "Environmental Testing Test B: High Temperature Test Method for Electrical and Electronic Products". Meets the requirements of GB/T2423.2 test method standard.

It has the following performance characteristics:

The shell is made of high-quality thin steel plate and the surface is sprayed with plastic; The inner liner is made of stainless steel sheet;

Fuji temperature controller from Japan;

■ Wide temperature test range;

■ Pt100 platinum resistor as sensor;

High temperature control sensitivity and good temperature uniformity;

■ Equipped with leakage protection, over temperature alarm, and over temperature protection functions.



controller

Imported microcomputer temperature and humidity integrated controller (temperature directly displays percentage)

Accuracy range

Setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% R? H, Indication accuracy: Temperature ± 0.1 ℃, Temperature ± 0.1% R? H

Temperature and humidity sensor

Platinum resistance? PT100Ω

heating system

Completely independent system, nickel chromium alloy electric heating heater

Humidification system

External isolation type, all stainless steel boiler type shallow surface evaporative humidifier

Dehumidification system

Adopting evaporator coil dew point temperature laminar contact humidifier

Water supply system

The humidification water supply adopts automatic control and can recycle residual water, saving water and reducing consumption

refrigeration system

Fully enclosed air-cooled single-stage compression refrigeration method/Original "Taikang"/Fully enclosed air-cooled double selection compression refrigeration method

circulatory system

Temperature resistant and low-noise air conditioning motor, multi blade centrifugal fan


1. Observe whether the indoor circulating fan is working properly. If it is burnt out and does not work, the evaporation cannot function properly, resulting in the inability to cool down.

2. Determine if there is voltage supplied to the compressor, such as whether the AC contactor connected to the compressor unit is engaged? Is the wire connecting the compressor constantly breaking or poorly connected? And determine whether the voltage meets the rated voltage requirements of the compressor.

3. To determine the current of the compressor unit, the current must reach the rated current of the compressor. If the voltage is normal but the current does not meet the requirements, it indicates a lack of refrigerant.

4. If the high-temperature test chamber is a stacked unit, observe whether both units are running. If one unit is not working, it should be stopped immediately for inspection. Identify the cause of the malfunctioning compressor and analyze and resolve it.

5. Observe whether the cooling fan of the condenser is working and whether the direction of the cooling fan is normal? During normal operation, the wind direction should blow outward.

6. Determine whether the compressor in the high-temperature test chamber is lacking refrigerant, and use a pressure gauge to observe whether the pressure after the compressor is started is normal when the equipment is working? Or feel the temperature of the high-pressure exhaust pipe of the compressor by hand. Normally, the temperature should be very high and hot to the touch. If it is a dual unit refrigeration system, it is necessary to determine which compressor is lacking refrigerant.



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!