Testing the time characteristics of high-voltage switch closing, opening, and contactor suction, release time, bounce, synchronization, and mechanical life operation of the contactor. It is suitable for testing the characteristics of high-voltage switches (or double coil independent opening and closing self locking contactors and air switches) with independent closing and opening coils (with locking mechanisms), as well as for testing the characteristics of contactors with only a single coil (electrically holding, without locking mechanisms) for opening and closing.
Use power supply
◇ Working power supply: voltage AC220V ± 10%, frequency 50Hz ± 10%
◇ Control power supply: external AC 0-380, DC 0-250
Output control: The output voltage can control the output.
Usage environment
◇ Environmental temperature: -20 ℃~50 ℃
Relative humidity: ≤ 80%
safety performance
◇ Insulation resistance:>2M Ω
◇ Leakage current: < 3 5mA
◇ Dielectric strength: The power supply incoming line can withstand 1500V (50Hz effective value) for 1 minute to withstand voltage to the casing.
Time testing
|
|
Absorption (release) time |
Three phases with different time periods |
unit of time |
|
display range |
0~999 |
999 |
ms |
|
error |
≤1 |
≤1 |
ms |
|
print data |
0~999.9 |
999.9 |
ms |
|
resolution |
≤0.1 |
≤0.1 |
ms |
◇ Operating cycle: 2 seconds