Special process conditions, such as positive pressure state orFor negative pressure operation, please contact us when selecting
1、 Fluoroplastic Magnetic Pump CQB-F Product Features:
The leak proof design eliminates the shaft seal and uses magnetic coupling to indirectly drive, completely eliminating the trouble of dripping and not polluting the usage site. Due to the use of "fluoroplastic alloy" for the overcurrent part of the pump. It can continuously transport corrosive media such as acids, alkalis, and strong oxidants of any concentration without damage.
2、 Working principle of CQB-F fluoroplastic magnetic drive pump:
The driving device adopts an active magnetic coupling directly installed on the motor shaft, and the pump chamber is completely enclosed. The impeller with a magnet on the pump shaft is indirectly driven by magnetic coupling, which is compact, reliable and energy-saving.
The sturdy and durable pump body structure, although the liquid contact part is made of fluoroplastic, the pump housing is made of metal material, so the pump body is able to withstand the weight of the pipeline and withstand mechanical impacts.
3、 Installation and commissioning of CQB-F fluoroplastic magnetic drive pump:
(1) Magnetic pumps should be installed horizontally and not vertically. The plastic magnetic drive pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must be facing upwards.
(2) When the suction liquid level is higher than the pump centerline, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump centerline, the pipeline needs to be equipped with a bottom valve.
(3) Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal noise, and all fasteners should be tightened.
(4) Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.
(5) After the motor starts, slowly open the discharge valve and adjust it to the desired opening after the pump enters normal working condition.
(6) Before the pump stops working, the discharge valve should be closed first, and then the power should be cut off.
4、 CQB-F Fluoroplastic Magnetic Drive Pump Product Usage:
The CQB-F fluoroplastic magnetic drive pump is widely used in industries such as petrochemicals, acid and alkali production, non-ferrous metal smelting, acid washing processes in automotive manufacturing, rare earth separation, pesticides, dyes, pharmaceuticals, papermaking, electroplating, and radio.
Operating temperature: -20 ℃ to 12 ℃0 ℃.
CQB65-50-160FA |
|||
CQB |
Magnetic driven chemical pump |
65 |
The imported diameter is 65mm |
50 |
The outlet diameter is 50mm |
160 |
The nominal diameter of the impeller is160mm |
F |
The overcurrent component is made of fluoroplastic |
A |
improved |
model | internet traffic (m³/h) |
Head (m) | Speed (2900r/min) | caliber (mm) |
Motor power (KW) | |
NPSH (m) cavitation allowance | Import | Export | ||||
CQB16-12-50F | 0.5 | 2 | 9 | 16 | 12 | 0.025 |
0.8 | 1.5 | |||||
CQB15-15-65F | 0.8 | 3.5 | 6 | 15 | 15 | 0.18 |
1 | 2.8 | |||||
CQB20-15-75F | 1.6 | 7 | 6 | 20 | 15 | 0.18 |
1.8 | 6 | |||||
CQB25-20-100F | 2.5 | 10 | 6 | 25 | 20 | 0.37 |
CQB32-20-110F | 4 | 13.5 | 6 | 32 | 20 | 0.55 |
5.5 | 13 | |||||
CQB32-20-125F | 2.5 | 21 | 6 | 32 | 20 | 0.75 |
3.6 | 20 | |||||
CQB32-20-160F | 3.6 | 32 | 5 | 32 | 20 | 1.5 |
CQB40-25-120F | 6.3 | 15 | 5 | 40 | 25 | 0.75 |
CQB40-25-125F | 6.3 | 20 | 4.5 | 40 | 25 | 1.1 |
CQB40-25-160F | 4 | 33 | 5 | 40 | 25 | 3 |
6.3 | 32 | |||||
8 | 29 | |||||
CQB40-25-200F | 4 | 51 | 3.7 | 40 | 25 | 1.1 |
6.3 | 50 | |||||
8 | 48 | |||||
CQB40-40-125F | 6.3 | 17.5 | 3.7 | 40 | 40 | 1.1 |
CQB50-32-125F | 7 | 22 | 3.5 | 50 | 32 | 1.5 |
12.5 | 20 | |||||
15 | 19 | |||||
CQB50-32-160F | 7 | 33 | 3.5 | 50 | 32 | 4 |
12.5 | 32 | |||||
15 | 29 | |||||
CQB50-32-200F | 7 | 52 | 3.5 | 50 | 32 | 7.5 |
12.5 | 50 | |||||
15 | 45 | |||||
CQB65-50-125F | 15 | 22 | 4 | 65 | 50 | 4 |
20 | 20 | |||||
25 | 15 | |||||
CQB65-50-150F | 15 | 27 | 4 | 65 | 50 | 4 |
20 | 25 | |||||
25 | 20 | |||||
CQB65-50-160 | 15 | 33 | 4 | 65 | 50 | 5.5 |
20 | 32 | |||||
25 | 28 | |||||
CQB65-50-160FA | 10 | 35 | 4 | 65 | 50 | 4 |
17.5 | 32 | |||||
19 | 25 | |||||
CQB65-50-180F | 15 | 40 | 5.5 | 65 | 50 | 5.5 |
20 | 38 | |||||
25 | 32 | |||||
CQB65-40-200F | 15 | 51 | 4 | 65 | 40 | 11 |
20 | 50 | |||||
25 | 45 | |||||
CQB80-65-125F | 35 | 22 | 4 | 80 | 65 | 7.5 |
50 | 20 | |||||
60 | 15 | |||||
CQB80-65-160F | 35 | 34 | 4 | 80 | 65 | 11 |
50 | 32 | |||||
60 | 28 | |||||
CQB80-50-200F | 35 | 51 | 4 | 80 | 50 | 18.5 |
50 | 50 | |||||
60 | 45 | |||||
CQB100-80-125F | 65 | 22 | 5 | 100 | 80 | 11 |
100 | 20 | |||||
120 | 18 | |||||
CQB100-80-160F | 70 | 34 | 5 | 100 | 80 | 18.5 |
100 | 32 | |||||
120 | 28 | |||||
CQB100-65-200F | 100 | 50 | 4 | 100 | 65 | 30 |
Note: If the specifications and models exceed this range, our factory can adjust them according to user requirements |
use and maintenance
Installation and precautions of fluoroplastic magnetic pump:
1. Prepare the concrete foundation according to the basic dimensions, and provide buried foot bolts at the same time.
2. Before installation, the pump and motor should be inspected to ensure that all parts are intact and free of debris inside the pump.
3. Place a pair of wedge pads between the base plate and the foundation, and use high-speed pads to align the level of the pump.
4. The suction and discharge pipelines of the pump should have brackets and cannot be supported by the pump. The diameter of the inlet and outlet pipelines should be consistent with the diameter of the pump inlet and outlet.
5. When installing the FZB series self-priming pump, the inlet pipe should be connected first, and the outlet pipe should be connected after filling with liquid to correct the direction of rotation. The inlet pipeline of the pump must be matched with the pump and the total length cannot exceed 5 meters.
6. After installation, turn the coupling by hand and check for any scratches.
7. Magnetic pumps are strictly prohibited from extracting media containing particles.
8. To prevent debris from entering the pump, a filter should be installed at the inlet, with a filtration area greater than 3-4 times the cross-sectional area of the pipeline.
9. Pumps with high head should also be equipped with check valves on the outlet pipeline to prevent water hammer damage caused by sudden shutdown.
10. It is necessary to ensure that the installation height of the pump meets the cavitation allowance of the pump, and consider pipeline losses and medium temperature.
11. When the medium temperature is too high, cooling measures should be taken for the mechanical seal to prevent deformation and cracking of the static ring.
Fluoroplastic magnetic pump startup and operation:
1. Before driving, the pump should be filled with the liquid to be transported (if the pump is suction), the outlet gate valve should be closed, and the power supply should be connected.
2. Connect the power and check if the pump's direction of rotation is correct.
3. Test run the unit for 3-6 minutes, and if there are no abnormal phenomena, it can be put into operation.
4. When shutting down, the gate valve at the outlet should be closed first, and then the power should be cut off.
Repair and maintenance of fluoroplastic magnetic pump:
1. Regularly inspect the pump and motor, and replace vulnerable parts.
2. When the pump is not in use for a long time, the flow channel inside the pump should be cleaned and the power should be cut off
3. Air freight transfer is strictly prohibited.
Faults and troubleshooting methods
Fluoroplastic magnetic pump cannot produce liquid:
1. There is air in the suction pipe. 2. There is air leakage in the suction pipe. 3. Insufficient liquid filling in the pump. 4. Blockage of debris in the suction pipe. 5. Pump reversal. 6. The suction height is too high
solution
1. Refill the liquid or evacuate the gas 2. Check the suction line 3. Refill the liquid 4. Remove blockages and debris 5. Adjust the steering 6. Lower the installation height
Insufficient flow rate of fluoroplastic magnetic pump:
1. Impeller damage 2. Insufficient speed 3. Blockage of debris in the pipeline
solution
1. Replace the impeller 2. Check the motor and power supply circuit 3. Remove blockages and debris
Fluoroplastic magnetic pump with excessive power:
1. The specific gravity of the conveying medium is too high. 2. The error between the pump axis and the motor axis is too large. 3. There is mechanical friction
solution
1. Reduce viscosity or increase infusion pressure 2. Adjust again 3. Check where the friction is and perform maintenance
Insufficient head of fluoroplastic magnetic pump:
1. There is air in the conveying medium. 2. The impeller is damaged. 3. The speed is insufficient. 4. The specific gravity of the conveying medium is too high
solution
1. Refill the liquid or evacuate the gas. 2. Replace the impeller. 3. Check the motor and power supply lines. 4. Reduce viscosity or increase injection pressure
Vibration of fluoroplastic magnetic pump assembly:
1. The error between the pump axis and the motor axis is too large. 2. The suction height is too high, causing cavitation. 3. There is mechanical friction
solution
1. Adjust again. 2. Lower the installation height. 3. Check where the wear is and conduct maintenance
Fluoroplastic magnetic pump shaft end leakage and sealing leakage:
1. The clearance between the shaft end snap rings is too large, and the snap rings are loose. 2. The suction height is too high, causing cavitation. 3. The mechanical seal dynamic and static rings are worn, and the spring pressure is low. 4. The mechanical seal dynamic and static rings do not fit well
solution
1. Adjust the snap ring screw. 2. Lower the installation height. 3. Replace the worn material and adjust the spring. 4. Adjust the dynamic and static rings