Hangzhou Qikun Technology Co., Ltd
Home>Products>CD-800s/800 Total Organic Carbon Analyzer
CD-800s/800 Total Organic Carbon Analyzer
The CD-800s/800 Total Organic Carbon Analyzer is independently developed and produced by Hangzhou Qikun Technology Co., Ltd. It uses the high-temperat
Product details

Principle of CD-800s/800 Total Organic Carbon Analyzer

By using high-performance oxidation catalysts in a combustion furnace, the sample is fully burned and decomposed into carbon dioxide and water at high temperatures. The water vapor is removed after cooling by a condenser, and the carbon dioxide is measured using a non dispersive infrared detector (NDIR) to determine the total organic carbon content in the sample; The inorganic carbon in the sample is decomposed into carbon dioxide and water using an acid reagent. The water vapor is removed by cooling with a condenser, and the carbon dioxide is measured using a non dispersive infrared detector (NDIR) to determine the total inorganic carbon (TIC) content in the sample; Total organic carbon TOC=TC-TIC.

Technical parameters of CD-800s/800 total organic carbon analyzer

Analysis method: High temperature oxidation NDIR detection principle

Detectable items: TC、IC、TOC、NPOC

TOC detection range: 0.050~35000mg/L

Detection accuracy: 0.050mg/L

Combustion furnace temperature: up to 1100 ℃

Accuracy error: ≤ ±5%

Injection volume: 20-1000ul

Analysis time: 3-8 minutes

Repetitive error: ≤ 3%

Zero drift: ≤ ±2%/D

Range drift: ≤ ±2%/D

Acid reagent: phosphoric acid solution

Carrier gas: high-purity oxygen (≥ 99.999%)

Environmental temperature: 0-40 ℃

Relative humidity: ≤ 85%

Power requirements: 220V AC ≤± 10% 50Hz (reliably grounded)

Power: 800W

Basic dimensions: 60cm × 43cm × 42cm

Weight: 40kg

Product Features

1. 7-inch touch screen, user-friendly interface, easy and convenient operation;

2. Three tube electronic condensation dehydration technology ensures the dehydration efficiency of the entire system;

3. A highly reflective gold-plated chamber, a highly concentrated infrared light source, and a highly sensitive infrared detector ensure excellent performance of NDIR, with sufficient sensitivity and accuracy for measuring ppb level data;

4. The maximum temperature can reach 1100 ℃, and different catalysts (such as CeO, Pt, CuO) and temperatures can be selected according to the sample;

5. The detection curve is visible in real-time, making it more intuitive;

6. Automatic injection of liquid samples, precise electromagnetic metering pump to ensure the accuracy and stability of the injection volume;

7. Real time self-monitoring of temperature, pressure, and flow at multiple locations;

8. The combustion furnace heating adopts multiple protections, and overheating can automatically cut off the heating, improving product safety performance;

9. The inorganic carbon reaction tank is designed with a heating device, which eliminates the tailing of sample peaks and shortens the sample measurement time;

10. Built in needle printer to reduce space occupation;

11. 2-year data storage capacity, easy to query, and can be queried by time period;

12. It has password protection function;

13. Optional online module for online monitoring;

14. Optional automatic sampling device can be used to achieve unmanned operation, saving manpower and time;

15. Configurable solid sampler for injecting solid samples into the sample boat;

16. Compliant with international standard ISO8245, National Environmental Protection Standard HJ501-2009 of the People's Republic of China, and National Metrological Verification Regulations JJG 821-2005 of the People's Republic of China.

Application scope

Clean validation in the pharmaceutical industry

L Tap water, surface water, river and lake water

Domestic sewage and industrial wastewater

Chemical water (cleaning water, cooling water, recycled water, etc.)

Laboratory research


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!