structure and principle
This machine mainly consists of a fixed frame, weighing frame, bearing seat, tension sensor, universal joint bearing amplifier, and microcomputer. When the tape conveyor transports materials, the weight of the materials will be transmitted to the tension sensor through the weighing frame, and through the microcomputer automatic processing system, the gravity signal will be converted into a flow signal and displayed.
Main technical parameters
Applicable bandwidth: 500mm -2000mm
Flow rate: 0.1-2000t/h
Measurement accuracy: ± 0.25% - ± 1.0% (cumulative amount)
Usage speed: ≤ 2.0m/s
Material temperature: ≤ 80 ℃ Tilt angle: ≤ 18°
Flow limit: Relay contacts
Ton pulse: arbitrary setting (NPN, CE junction)
Lower limit of flow: relay contact