Beidouxing Industrial Chemistry Research Institute, Haidian District, Beijing
Home>Products>Beidou Instrument Petroleum Condensation Point Online Testing System
Beidou Instrument Petroleum Condensation Point Online Testing System
The Beidou Instrument Petroleum Condensation Point Online Testing System is a petroleum condensation point online system that uses electronic refriger
Product details

Beidou Instrument Petroleum Condensation Point Online Testing System

Purpose:

Online analysis of liquid pour point, cloud point, freezing point, and freezing point.

?Measurement principle:

This instrument is based on the principle of cold mirror measurement. The probe consists of a cold pump and a mirror surface located on its cold side, and the temperature sensor is embedded in the mirror surface; The heat generated by the third and fourth stage cold pumps is dissipated through heat pipes and fans. The optical reflection system composed of a light-emitting tube and a receiving tube detects the condensation state. By detecting the light signal, the refrigeration current is closed-loop controlled to maintain the condensation state and achieve continuous detection. The temperature sensor directly measures the condensation point temperature. Analysis standards: ASTM D 5949, SH/T 0771-2005 Chinese National Standard.

?Product features:

lMeasuring the condensation point is more direct and accurate than other principles, and can avoid errors caused by inertia and hysteresis

lThe system is very stable and does not require recalibration for long-term use

lMeasure balance indicator. Capable of self judging the measurement process and indicating whether the measurement is balanced

Beidou Instrument Petroleum Condensation Point Online Testing System

?Technical parameters:

lMeasurement parameter: condensation point temperature

lMeasurement range:- 60 ℃ maximum and below 10 ℃ ambient temperature

-60 ℃ and 20 ℃ ambient temperature

-55 ℃ 35 ℃ ambient temperature

-45 ℃ 40 ℃ ambient temperature

lresolving power:0.1℃

lRepetition accuracy: ≤ ±2℃

lAccuracy: ≤ ±4℃

  • electricity  Voltage: 12 or 24 VDC

  • work  Rate: 60W

  • Environmental temperature: -20 ℃~50 ℃ (for storage and use)

  • Connection interface: DN25PN1.6 French blue

  • Balance time: 0-8 minutes

  • Sampling liquid flow rate: 0.1-0.5l/min

  • Sampling liquid pressure: minimum 10mbar, standard 1.6MPa, maximum 4.0MPa; Sampling diameter 8mm;

  • Instrument function:

  • Output 1-channel 0-5V, 0/4-20mA linear standard signal (initially 0-20mA). It can be directly used for connecting displays, recorders, or other secondary meters or acquisition systems. Can be enhanced to PID closed-loop control

  • Equipped with RS232/485 communication port, initially tested as STIMcom according to IEEE1451.2 standard, Modbus protocol can be selected

  • Support fieldbus instrument networking

  • The output signal range and alarm limit can be set, with sound and light alarms. The system outputs a 1-channel 0/5V switch alarm signal, which can be connected according to user requirements

  • On site fixed 2 × 16 LCD display data; 4x5 keyboard

Beijing Beidouxing Industrial Chemistry Research Institute

Beijing Beidouxing Technology Co., Ltd

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!