Beidou Instrument Biogas Composition AnalyzerpGAS200

Principle:The gas sensor adopts infrared photometer and electrochemical testing principle

Application:

lFermentation industry gas detection

lGas detection in landfill sites

lRapid analysis of the main components of biogas

Instrument features:

lElectrochemical probe for direct sampling

lSelect the gas to be detected based on the actual situation of the user

lSimultaneous detection of fermentable substances can be achieved on a single instrumentHCCO2H2NH3H2SO2Different gas contents

lEquipped with convenient backpack, printing and reading functions, it is particularly convenient and applicable for on-site testing or laboratory testing of on-site sampling

Instrument function:

lAll operation keyboard settings, window prompts

lsceneLCD 4×20characterSymbol rotation displays multiple environmental parameters

lCan be equipped with a serial micro printer

lSupport calorific value calculation

lQuickly detect parameters and temperature values, and perform temperature correction and cross correction

lInert gas software zeroing, standard sample or substitute calibration

Beidou Instrument Biogas Composition AnalyzerpGAS200

Technical parameters:

ldivide distinguish Rate:0.025%FS

lRepetition accuracy:0.05%FS

lResponse time:<1min

lSampling temperature: 0~40℃

lSampling pressure: 0.9~1.1 kgf/cm2

lpower supplypower supply: 12V rechargeable battery

lSampling temperature: 0~40℃

lSampling pressure: 0.9~1.1 kgf/cm2

lLong term stability:±10% /Year by year(general)

lEnvironmental temperature for use:-10℃~60℃Humidity:10%~90%R(No condensation)

lStorage environment temperature:0℃~50℃Humidity:10%~80%R(No condensation)

pGAS200

Detection parameters:

gas

range

repeatability

hydrocarbonHC

0~100%

5%R

carbon dioxideCO2

0~25/100%

±0.2%

ammoniaNH3

0~1000ppm

1%

hydrogenH2

0~4%

1%

oxygenO2

0.1~30%

1%

hydrogen sulfideH2S

0~500ppm

1%