BXS-800 expandable test boxThe test chamber is mainly used in industries such as pharmaceuticals, medicine, biotechnology, food industry, electronics industry, and all related fields including life sciences. It is a scientific method to create a long-term stable temperature, humidity, and lighting environment for drug failure evaluation. It is suitable for pharmaceutical companies to conduct accelerated testing, long-term testing, and high-temperature testing of drugs and new drugs. It is the best choice for pharmaceutical companies to conduct drug stability testing.
BXS-800 expandable test boxLCD touch screen, oversized4.3inchTFT16True color display;
Touch based operation makes experimental operations simpler;
blurPIDControl, programmatic multi segment parameter settings:30paragraph99Cycle design;
Adopting imported energy-saving and environmentally friendly compressors and imported high-performance fans;
Data storage function, capable of saving25Ten thousand data records;
Real time viewing of instrument temperature record data (latest time)1600Article);
Variable frequency refrigeration system, temperature quickly recovers after opening the door;
Screen saver password lock function prevents unauthorized operation;
Improve protection functions: over temperature limit alarm and shutdown protection, door opening alarm, sensor fault alarm;
USBDirectly export memory data and instrument event records (including startup, shutdown, menu parameter settings, fault alarms, etc. with exact time);
Design of glass internal observation door;
C.H.Circulating heat system, improving the utilization of residual heat and reducing heating time;
Device ConfigurationUSBInterfaceRS232andRS485Interface;
Standard mechanical lock to prevent unauthorized opening of doors;
Standard embedded printer;
OptionalGPRSSMS alarm,FDA/GMP computer monitoring.

Model:BXS-800
Temperature control range:0-70℃
Resolution:0.1℃
Volatility(At 25 ℃:±0.5℃
Uniformity(At 25 ℃:±1.5℃
input power2100W
Timing range:30 paragraphs99 cycles/Each paragraph1-9999 hours
Inner container size (length)X widthX High)(mm):1220×585×1123
Dimensions (length)X widthX High)(mm):1503×910×1820
Load carrier (standard)/At most:8 yuan/16 yuan
Scalable system:
name |
configuration |
feature |
Humidity control system |
Imported high-precision humidity sensor, water level sensor, humidification water tank, humidification electric heating tube and other complete humidity control systems |
Real time viewing of instrument temperature and humidity record data (latest time)1600Article); |
Lighting control system |
Shelf type lighting module: including a complete set of lighting control modules such as lighting sensors, driver modules, and a set of shelf type lighting systems |
The illuminance is infinitely adjustable and can run for a timed time. It will automatically turn off when the total value is reachedLEDLamp; |
Shelf type lighting source |
The illuminance is automatically adjusted by the lighting module and cannot be displayed or printed |
|
UV control system |
Shelf type UV module: including a complete set of UV control modules such as UV amplitude sensor, driver module, and a set of shelf type UV system |
The UV value is infinitely adjustable, and the controller is equipped with a UV radiation value total calculator. When the total value is reached, the UV lamp will automatically turn off; |
Shelf type UV light source |
The UV value is automatically adjusted by the UV module and cannot be displayed or printed |
Technical parameters for humidity expansion:
Moisture control range:30%-95%
Humidity fluctuations:±5%
input power2700W
Note: The temperature control range, resolution, fluctuation, uniformity, timing range, inner container size, external dimensions, and load carrier are the same as the basic model.
Light (UV) extension technical parameters:
Temperature control range: in the absence of light0-70 ℃, under illumination10-70℃
Range of illumination:0-10000 Lux (infinitely adjustable)
Illuminance deviation:±500Lux
UV amplitude value:0~2W/m2
UV spectral range:320~400nm
input power/Number of illuminated shelves:2400W/2 sets
Shelf type lighting (UV) module:1 group
Shelf type UV light source (maximum):5 groups
Note: The resolution, fluctuation, uniformity, timing range, inner container size, external dimensions, and loading bracket are all the same as the base model.
The UV amplitude value and UV spectral range parameters are applicable to the UV extended version.
humidity+Light (UV) extension technical parameters:
Temperature control range: in the absence of light0-70 ℃, under illumination10-70℃
Moisture control range:35%-95%
Humidity fluctuations:±5%
Range of illumination:0-10000 Lux (infinitely adjustable)
Illuminance deviation:±500Lux
UV amplitude value:0~2W/m2
UV spectral range:320~400nm
input power/Number of illuminated shelves:3000W/2 sets
Shelf type lighting (UV) module:1 group
Shelf type UV light source (maximum):5 groups
Note: The resolution, fluctuation, uniformity, timing range, inner container size, external dimensions, and loading bracket are all the same as the base model.
The UV amplitude value and UV spectral range parameters are applicable to humidity+UV extension.
Note: Working environment temperature:10~30℃Working power supply:~220V±10V50/60Hz
Optional accessories:
name |
description |
|
Humidity control module |
Including humidity control system and complete set of humidification accessories |
|
Shelf typemodule |
Single light illumination |
Including a complete lighting control system, a set of shelf style lighting modules, and a set of shelf style lighting sources |
Single Purple Outside |
Including a complete UV control system, a set of shelf mounted UV modules, and a set of shelf mounted UV light sources |
|
Illumination UV |
Including a complete set of lighting UV control system, a set of shelf type lighting UV modules, and a set of shelf type lighting UV light sources |
|
Shelf type light source |
Single light illumination |
The illuminance is automatically adjusted by the lighting module and cannot be displayed or printed |
Single Purple Outside |
The UV value is automatically adjusted by the UV module and cannot be displayed or printed |
|
Illumination UV |
The illuminance and UV value are automatically adjusted by the UV module, and cannot be displayed or printed |
|
monitoring software |
FDAedition |
satisfiableFDArequirement |
GMPedition |
satisfiableGMPrequirement |
|
Additional shelves |
In addition to the standard shelves, optional shelves are also required |
|
GPRStext message alert |
After the alarm is generated, send the alarm status SMS to the designated mobile phone |
|
Wireless temperature and humidity recorder |
Comes with data analysis software that can convert analyzed data into various formats for user calibration and verification |
|
Wireless temperature recorder |
Comes with data analysis software that can convert analyzed data into various formats for user calibration and verification |
|
3QVerification document |
Provide complianceGMPrequired3QVerification document |
|
Wireless Temperature Recorder Measurement Certificate |
3A point(0℃The60℃The121℃) |
|
Wireless Temperature and Humidity Recorder Measurement Certificate |
3A combination(15℃/40%RHThe20℃/60%RHThe30℃/80%RH) |
|