BINDER KB720 Low Temperature Incubator
BINDER KB720 Low Temperature Incubator
Product details

BINDER KB720 Low Temperature Incubator

1、 Product Introduction:

1. Temperature range: -5 ℃ to 100 ℃

2 APT.line ™ Internal preheating technology

3. Compared to the previous generation product, it can save up to 30% energy consumption

4. Cooling through a compression cooler

5. Door heating

6. Adjustable fan speed

7. Controller using interval programming and real-time programming

8. Interior door made of safety glass (ESG)

9. Two sockets made of stainless steel

10. 4 casters, 2 with brakes

11. Access hole with silicone plug 30mm, left

12. Independent adjustable temperature safety device, Class 3.1 (DIN 12880), equipped with optical and sound alarms

13. Computer interface: Ethernet

2、 Technical parameters:

Product model KB720-230V1 KB720UL-240V1
Choose a model standard standard
Item code 9020-0204 9020-0306
measure
Internal volume [L] 698 698
Net weight of equipment (unloaded) [kg] 304 304
Maximum total load [kg] 150 150
Maximum load per partition [kg] 45 45
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 1250 1250
Net weight at height [mm] 1925 1925
Depth net weight [mm] 885 885
Wall distance from rear [mm] 100 100
Wall to side distance [mm] 100 100
Internal dimensions
Width [mm] 970 970
Height [mm] 1250 1250
Depth [mm] 576 576
The number of doors
Inner door 2 2
Outer door 2 2
Data related to the environment
Energy consumption at 37 ℃ [Wh/h] 360 360
Sound pressure level [dB (A)] 53 53
firmware
Number of partitions (hours/maximum) 2/15 2/15
Temperature performance data
Temperature range [℃] -5…100 -5…100
The temperature deviation is 37 ℃ [± K] 0.2 0.2
Temperature fluctuation at 37 ℃ [± K] 0.1 0.1
The recovery time after opening the door in 30 seconds is 37 ℃ [min] 3 3
Electrical data
Rated voltage [V] 200…240 200…240
Power frequency [Hz] 50/60 50/60
Rated power [kW] 2.3 2.3
Equipment safety device [A] 16 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.