Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER FD115 drying oven
BINDER FD115 drying oven
BINDER FD115 drying oven
Product details

BINDER FD115 drying oven

1、 Product Introduction:

1. Temperature range: ambient temperature plus 10 ℃ to 300 ℃

2. Up to 30% more energy-efficient than common devices on the market

3. Utilizing APT.line ™ Technology achieves high temperature accuracy

4. Circulating air

5. Controller with LCD display

6. Exhaust valve electromechanical control

7. 2 chrome plated sockets

8. Stackable

9. Integrated independently adjustable temperature safety device level 2 (DIN 12880) with optical alarm

10. Ergonomic handle design

11. USB interface for recording data

2、 Technical parameters:

PRODUCT MODEL FD115-230V1 FD115UL-120V1
Choose a model standard standard
Item code 9010-0305 9010-0306
measure
Internal volume [L] 116 116
Net weight of equipment (unloaded) [kg] 50 50
Maximum total load [kg] 150 150
Maximum load per partition [kg] 30 30
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 710 710
Net weight at height [mm] 735 735
Depth net weight [mm] 605 605
Wall distance from rear [mm] 160 160
Wall to side distance [mm] 100 100
Internal dimensions
Width [mm] 550 550
Height [mm] 550 550
Depth [mm] 385 385
The number of doors
Outer door 1 1
Data related to the environment
Energy consumption at 150 ℃ [Wh/h] 340 340
Sound pressure level [dB (A)] 43 43
firmware
Number of partitions (hours/maximum) 2/5 2/5
Temperature performance data
The temperature range exceeds the indoor temperature by 10 ℃ to [℃] 300 300
Temperature deviation is 150 ℃ [± K] 1.7 1.7
Temperature fluctuation at 150 ℃ [± K] 0.3 0.3
Heating time to 150 ℃ [min] 18 18
The recovery time after opening the door in 30 seconds is 150 ℃ [min] 4 4
Electric data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 1.3 1.4
Equipment safety device [A] 6.3 12.5
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!