BD series/natural convection microbial incubator
The BD series incubator is designed specifically for sensitive microorganisms, and the newly designed product has a uniform temperature distribution, ensuring an ideal cultivation environment and obtaining perfect experimental results.
• Performance characteristics and equipment
-Electronic controlled APT.line® Internal preheating technology
-Temperature range: from 5 ° C above ambient temperature to 100 ° C\
-Controller with LCD display screen
-Independent adjustable temperature safety device, Class 3.1 (DIN12880), equipped with optical alarm
-Mechanical controlled ventilation opening
-The door handle conforms to the principles of ergonomics
-Interior door made of safety glass (ESG)
-Used for communication software APT COM® The Data Control SystemRS422 interface
-Boxes of 115 liters or less can be stacked
-2 chrome plated shelves
Only BINDER products: Accurate regardless of size - even for 20 liter desktop boxes.
Technical specifications of BD series
BD23 |
BD56 |
BD115 |
BD260 |
BD400 |
BD720 |
|
Dimensions |
||||||
Width (millimeters) |
435 |
560 |
710 |
810 |
1235 |
1235 |
Height (millimeters) |
495 |
625 |
735 |
965 |
1025 |
1530 |
Depth (millimeters) |
520 |
565 |
605 |
760 |
765 |
865 |
Add door handle, I-panel, and exhaust pipe (in millimeters) |
90 |
90 |
90 |
90 |
90 |
90 |
Distance between the rear and the wall (in millimeters) |
100 |
100 |
100 |
100 |
100 |
100 |
Distance between side and wall (mm) |
160 |
160 |
160 |
160 |
160 |
160 |
Steam space volume (liters) |
36 |
70 |
142 |
283 |
457 |
808 |
Number of doors |
1 |
1 |
1 |
1 |
2 |
2 |
Internal dimensions |
||||||
Width (millimeters) |
222 |
360 |
510 |
610 |
1000 |
1000 |
Height (millimeters) |
330 |
420 |
530 |
760 |
800 |
1200 |
Depth (millimeters) |
277 |
380 |
420 |
545 |
500 |
600 |
Internal volume (liters) |
20 |
57 |
112 |
253 |
400 |
720 |
Chrome plated shelves (standard quantity/maximum quantity) |
2/4 |
2/4 |
2/5 |
2/8 |
2/9 |
2/15 |
Load per shelf (kg) |
12 |
30 |
30 |
40 |
35 |
45 |
Allowable total load (kg) |
25 |
70 |
150 |
270 |
90 |
120 |
Weight (empty container) (kg) |
27 |
39 |
54 |
85 |
135 |
191 |
temperature data |
||||||
Temperature range: 5 ° C to (° C) above ambient temperature |
100 |
100 |
100 |
100 |
100 |
100 |
Temperature deviation: 37 ° C(±K)
|
05 |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
Temperature fluctuation range: 37 ° C(±k) |
0.2 |
0.2 |
0.1 |
0.2 |
0.1 |
0.1 |
Heating time: to 37 ° C (minutes) |
59 |
45 |
55 |
65 |
120 |
110 |
Recovery time after opening the door for 30 seconds: at 37 ° C (minutes) |
20 |
16 |
16 |
19 |
10 |
15 |
Electric data |
||||||
Protection level of enclosure in accordance with EN60529 standard |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Nominal voltage(±10%) 50/60 Hz (V) |
230 1N~ |
230 1N~ |
230 1N~ |
230 1N~ |
230 1N~ |
230 1N~ |
Nominal power (watts) |
200 |
300 |
350 |
850 |
850 |
1250 |
Energy consumption at 37 ° C (wh/h) |
11 |
25 |
25 |
40 |
56 |
80 |
Equipment safety device (A) |
12.5 |
6.3 |
6.3 |
8 |
12.5 |
16 |
All data is only applicable to22±3 ° C ambient temperature and±Standard specification unloaded equipment under 10% power supply voltage fluctuation. Determine temperature data according to BINDER factory standards and DIN12880:2007, and adapt to the recommended wall gap of 10% of the inner chamber height, width, and depth. For the series of devices, all data are typical averages, and technical changes are reserved.