AvaSR-96 portable solar spectral reflectometer
AvaSR-96 portable solar spectral reflectometer is specifically designed for national standardsThe product developed in accordance with JGJ/T287 "Energy saving Testing Standard for Building Heat Reflective Coatings" has a wavelength range of 350-2500 nm. It is mainly used for on-site measurement of solar reflectance of exterior wall heat reflective coatings, energy-saving glass, paint, metal and other materials in the field of building energy conservation. It is also suitable for formula research and production testing of coatings, paints and other materials, and can be used for both on-site and laboratory testing in engineering.
The AvaSR-96 portable solar spectral reflectometer has the characteristics of high cost-effectiveness, fast and accurate measurement, simple operation, and easy portability. It is equipped with complete engineering field testing accessories, and can be used not only for solar reflectance measurement but also for colorimetric measurement.
Instrument characteristics
1. A specialized spectral analysis software for measuring the solar reflectance of heat reflective coatings. The software has the functions of calculating the building's solar reflectance, reflection color, building energy-saving effect, and issuing test reports. It can intelligently prompt the testing weather and sampling number, and can view the original data points and 96 standard data points in real time. The administrator function ensures data security
2. Support national standards, industry standards, and international standards, such as GBT 25261-2010 "Reflective Thermal Insulation Coatings for Buildings"; JGJ/T287-2012 "Testing Standard for Building Heat Reflective Coatings"; JG/T235-2014 "Reflective Thermal Insulation Coatings for Buildings"; JC/T1040-2007 "Heat Reflective Thermal Insulation Coatings for Exterior Surfaces of Buildings"; ASTM C1549-2009 in the United States; And local application technical regulations and standards such as Guangdong DBJ15-75-2010, Hainan DBJ/46-023-2012, Shanghai DGTJ 08-2200-2016, Anhui DB34/T1505-2011, Chongqing DBJ/T50-076-2008, Guangxi DBJ/T45-001-2013, Jiangsu JG/T026-2009, Jiangxi DB36/J009-2012/T, Sichuan DBJ51/T021-2013.
3. Real time measurement of CIE1931 and CIE1964 color parameters is possible; X, Y, Z, x, y, z, L, a*, b*, H, C, u, v; Can display R, G, and B color images simultaneously, and can calculate the color difference with the reference color
4. The software has the ability to automatically calculate the energy savings per hour, per day, per month, and per year based on the solar reflectance and hemispherical emissivity data of the coating, and calculate the standard coal savings
5. Handle type specialized test probe; Real time portable wall mounted measurement
6. Wireless transmission of spectral data to achieve wireless remote measurement
7. Display of solar reflectance data, with customizable detection range for solar reflectance; Determine the pass rate
8. For different coating thicknesses (h=2.0, 1.5, 1.0, 0.5mm); Specialized integrating ball positioning plate that meets national standards
9. The host is dustproof and waterproof, safe and reliable;
10. Impact resistant instrument box (pull rod type), easy to carry.
technical data
parameter |
AvaSR-96 |
wavelength range |
350 - 2500 nm |
spectral resolution |
1.5 nm @ 350-1100 nm 15 nm @ 1050-2500 nm |
sampling interval |
0.6 nm @ 350-1100 nm 6 nm @ 1050-2500 nm |
Wavelength accuracy |
± 0.3 nm @ 350-1100 nm ±3 nm @ 1050-2500 nm |
Wavelength Repeatability |
± 0.1 nm @ ± 10 ° C temperature variation |
detector |
Back illuminated CCD detector, 2048 pixels, pixel size 14x500um 256 pixel InGaAs array, TE cooling |
linear |
Better than 99% |
integration time |
0.01 - 100 ms |
communication model |
wireless communication |
Handle type specialized probe |
Sampling port 10mm |
Temperature/humidity range |
0 ° C to 40 ° C (working state)- 15 ° C to 55 ° C (storage state); Dry until no condensation occurs; |
Host size/weight |
310x270x135mm/5.2kg |