DaZu Laser Technology Industry Group Co., Ltd
Home>Products>Air cooled chiller HC025M (SW)~HC200M (SW) dual temperature series
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13802266134
  • Address
    3rd Floor, Building 6, Dazu Laser Equipment Manufacturing Center, 128 Chongqing Road, Fuyong Street, Bao'an District, Shenzhen (at the junction of Chongqing Road and Fuyuan 1st Road)
Contact Now
Air cooled chiller HC025M (SW)~HC200M (SW) dual temperature series
Function introduction: HC025M-HC200M dual temperature series chillers have three commonly used temperature control accuracies to choose from, meeting
Product details

HC025M (SW)~HC200M (SW) Dual Temperature Series

Product Features

  • Multiple temperature control precision options to meet different needs, with optional temperature control accuracies of ± 0.1 ℃, ± 1.0 ℃, and ± 2.5 ℃

  • Dual temperature and dual circulation system, each temperature can be controlled separately (the temperature setting of the secondary circuit needs to be higher than that of the main circuit)

  • Efficient plate heat exchangers or corrosion-resistant titanium tube heat exchangers can be selected

  • External rotor fan, integrated air-cooled heat dissipation (optional water cooling method), upper air outlet method

  • Equipped with liquid level alarm, flow alarm, temperature alarm, phase sequence alarm, pressure alarm, and component fault alarm

  • Equipped with flow alarm, temperature alarm, and temperature ready signal output (optional)

  • Equipped with the function of recording the running time and start stop times of main components (optional)

  • Equipped with external control start and stop functions (optional)

  • Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)

  • Adopting stainless steel water pump and PE water tank, the water circulation system does not contain metals such as copper, aluminum, iron, etc., and will not rust at all

  • Circulating water fine filtration, filtration accuracy can be selected according to actual needs

Function Introduction

  • HC025M-HC200M dual temperature series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2.5KW to 20KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 20KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external circulating cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope

  • Fiber laser 500W/1000W/2000W/4000W/6000W/CNC machine tool/high-speed shaft, etc.

HC025M (SW)~HC200M (SW) Dual Temperature Series

Product Features

  • Multiple temperature control precision options to meet different needs, with optional temperature control accuracies of ± 0.1 ℃, ± 1.0 ℃, and ± 2.5 ℃

  • Dual temperature and dual circulation system, each temperature can be controlled separately (the temperature setting of the secondary circuit needs to be higher than that of the main circuit)

  • Efficient plate heat exchangers or corrosion-resistant titanium tube heat exchangers can be selected

  • External rotor fan, integrated air-cooled heat dissipation (optional water cooling method), upper air outlet method

  • Equipped with liquid level alarm, flow alarm, temperature alarm, phase sequence alarm, pressure alarm, and component fault alarm

  • Equipped with flow alarm, temperature alarm, and temperature ready signal output (optional)

  • Equipped with the function of recording the running time and start stop times of main components (optional)

  • Equipped with external control start and stop functions (optional)

  • Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)

  • Adopting stainless steel water pump and PE water tank, the water circulation system does not contain metals such as copper, aluminum, iron, etc., and will not rust at all

  • Circulating water fine filtration, filtration accuracy can be selected according to actual needs

Function Introduction

  • HC025M-HC200M dual temperature series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2.5KW to 20KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 20KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external circulating cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope

  • Fiber laser 500W/1000W/2000W/4000W/6000W/CNC machine tool/high-speed shaft, etc.

工业冷水机--风冷冷水机HC025M(SW)~HC200M(SW) (2).png

工业冷水机--风冷冷水机HC025M(SW)~HC200M(SW) (3).png

Function Introduction:

HC025M-HC200M dual temperature series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2.5KW to 20KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 20KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external circulating cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope:

Fiber laser 500W/1000W/2000W/4000W/6000W/CNC machine tool/high-speed shaft, etc.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!