Agilent 1290 Infinity Liquid Chromatography System
Agilent's new 1290 Infinity binary pump brings stable chromatographic performance, compatibility, and flexibility. Active damping combined with low la
Product details
Product Introduction

Agilent 1290 Infinity Liquid Chromatography System
Agilent's new 1290 Infinity binary pump brings stable chromatographic performance, compatibility, and flexibility. Active damping combined with low latency volume technology in Agilent Jet Weaver mixers provides fast gradient response and stable LC/UV and LC/MS performance.

The characteristics are as follows:
1200 bar pressure flow rate of 2 mL/min, 800 bar pressure of 5 mL/min, with analytical speed and separation, as well as compatibility with methods developed on other platforms
Low latency volume of 10 μ L - capable of fast gradient separation compatible with LC/MS and LC/UV applications
Dual core microprocessor - controlled active damping - compensates for solvent properties, provides real-time flow stability control, and reduces noise to a low level
Silicon carbide piston - prolongs the lifespan of the sealing gasket and prolongs the normal operation time of the instrument
Integrated degassing - enables the pump to quickly empty and inject solvents

Stable sensitivity


Featuring optical path design, including Agilent's Max Light cartridge flow cells with microfluidic optical waveguide technology, the 1290 Infinity diode array detector achieves the expected level of UV sensitivity and baseline stability. For LC/MS, Agilent's jet stream ion focusing technology improves the sensitivity of MS and MS/MS by stabilizing the spatial focusing of electric spray droplets.

1290 Infinity diode array detector with stable sensitivity
In order to achieve stable detector sensitivity for UHPLC and conventional HPLC, Agilent's microfluidic optical waveguide technology with a large optical strength card sleeve flow cell enables a 100% optical transmission rate without separation loss caused by cell diffusion effects, eliminating differential refractive index effects and significantly reducing baseline drift.

Low noise and high linearity - using a 10 mm Agilent * large light intensity card sleeve flow cell (Max Light cartridge cell)
• Stable sensitivity - using a 60mm Agilent Max Light high sensitivity cartridge cell with high light intensity and high sensitivity
• Stable peak integration processing due to reduced baseline drift
• Achieve multi wavelength and full spectrum detection at an acquisition rate of 160Hz - matching the speed of liquid chromatography analysis
Programmable slit (1 to 8 nm) - provides stable incident light, achieving stability in sensitivity, linearity, and spectral resolution
RFID barcodes for circulation pools and lights, data traceability and usage tracking
Simplified and user-friendly design - the card sleeve design makes the replacement of the circulation pool quick and easy
Stable flexibility
By using Agilent's quick switching valve in the 1290 Infinity column temperature chamber, a high-throughput, multi method, and automatic method development solution that saves resources has been achieved. A brand new component - the 1290 Infinity Flexible Cube, which can use a fixed quantitative tube injection mode to achieve fast cycle times or automatic needle recoil, reducing cross contamination.
Stable flexibility of 1290 Infinity automatic sampler
The 1290 Infinity automatic sampler is based on a flow-through design and can inject both large and small volume samples without replacing the sample quantification tube.
Designed for stable injection speed and minimal sample loss, this automatic sampler has the following features:

• Accuracy - Injection range 0.1-40 μ L
Low latency volume - suitable for fast gradients
Peltier temperature control range 4 to 40 ° C - suitable for heat sensitive samples
Overlapping injection - making the injection cycle short and fast
Good anti cross contamination performance - achieved through inert sealing gasket and needle seat sealing gasket materials

1290 Infinity Column Temperature Box
The temperature range of the 1290 Infinity column incubator ranges from 10 ° C below room temperature to 100 ° C, providing flexibility in separation in terms of speed and selectivity
The temperature stability parameter is ± 0.05 ° C, which ensures good reproducibility of retention time
Peltier cooling/heating improves application flexibility - two independent temperature control zones ranging from 10 ° C below room temperature to 100 ° C
Low volume heat exchanger - reduces peak diffusion
Spacious column box - can accommodate 3 30 cm chromatography columns or more short columns

Door opening sensor - improves stability and practicality,Achieve an analysis throughput of 2000 samples per day

The high-throughput configuration of 1290 Infinity liquid chromatography improves laboratory efficiency through high sample throughput. When analyzing with one chromatographic column, the regeneration pump cleans and regenerates the second column. With this high-throughput configuration, the cycle time can be reduced by 50%.

Stable Control of 1290 Infinity Liquid Chromatography System

Agilent Chemical Workstation for 1290 Infinity

Liquid chromatography provides stable instrument control. The new graphical user interface allows you to have a clear view of all important status parameters, browse all configured instruments, and directly enter all method settings.

Chemical workstations help improve the efficiency of commonly used separation techniques, including Agilent gas chromatography, liquid chromatography, LC/MS, CE and CE/MS, as well as many third-party detectors. This is a stable chromatographic data system.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!