AV3656A/B Vector Network AnalyzerProduct Overview:
AV3656A/B Vector Network AnalyzerSuitable for wireless communication, cable television, education, and automotive electronics fields, it can be used to measure the performance of RF components such as filters, amplifiers, antennas, cables, and cable TV taps. This product uses the Windows operating system; Equipped with error calibration function, time-domain function, and fixture simulator function; It has multiple display formats such as logarithmic amplitude, linear amplitude, standing wave, phase, group delay, Smith chart, polar coordinates, etc; Provide multiple calibration methods, including frequency response, single port, response isolation, enhanced response, full dual port, fast SOLT calibration, and electrical calibration functions; Capable of displaying multiple channels and windows; It has USB interface, LAN interface, GPIB interface, and VGA interface. It can quickly and accurately measure the amplitude, phase, and group delay characteristics of the S-parameters of the tested object, and has efficient and powerful error correction capabilities.
Main features:
●With a dynamic range of up to 125dB, it can accurately measure high suppression ratio devices;
●Can you choose 75? Test port impedance options for measuring cable TV components;
●The trace noise of 0.001dBrms enables the network analyzer to have higher testing accuracy;
●Provide up to 64 independent measurement channels to quickly execute complex testing plans;
●Powerful data analysis capabilities, such as ripple testing, bandwidth testing, limit testing, etc., facilitate users to make qualified judgments and improve testing efficiency;
●Equipped with a four port expansion option, it can be used in conjunction with a four port expansion device to achieve measurement of all 16 S-parameters in a four port network with a single connection, and can also perform balanced parameter measurement;
●Standard time domain analysis function;
●The fixture simulator can simulate various measurement scenarios in scientific research and production, and can quickly and real-time obtain corresponding measurement results;
●Equipped with LAN and GPIB interfaces, capable of remote control and system interconnection, and featuring four USB interfaces.
● Large dynamic range
The AV3656A/B has a dynamic range of up to 125dB (IFBW=10Hz), enabling precise measurement of high suppression ratio devices.
Extremely low trace noise
Trace noise is less than 0.001dBrms (IFBW=3kHz) to minimize measurement errors.
● Equipped with time-domain analysis function
The time-domain software function can be used for time-domain measurement of the tested component, comprehensively testing its performance indicators. For cable fault location and length measurement, etc.
●Powerful data analysis capabilities
It has multiple analysis functions such as limit testing, ripple testing, bandwidth testing, and automatic filter statistics, which provide a clear view of loss, ripple, and suppression, and facilitate the debugging of frequency hopping filters.
Typical applications
Production and testing of mobile communication products
The frequency range can meet the production and testing needs of mobile communication products, with characteristics such as fast scanning speed, large dynamic range, and small size. It is very suitable for batch production testing work in factories and can be used for testing RF components such as filters, amplifiers, antennas, cables, etc. It can also be selected as 75? Test components to measure the performance of cable TV components.
Passive multi port device and balancing device testing
The four port vector network analyzer, combined with the AV2813A S-parameter testing device, can measure all 16 S-parameters of the four port network with a single connection, making it very suitable for large-scale production testing of multi port devices in factories; Equipped with a balanced parameter measurement function, using three or four test ports, perform full three or full four port calibration, and select the corresponding working mode (single ended balanced network, single ended single ended balanced network, balanced balanced balanced network) to obtain the mixed S-parameters of the balanced device.
technical specifications
parameter |
AV3656A |
AV3656B |
Frequency range |
100kHz ~ 3GHz |
100kHz ~ 8.5GHz |
frequency resolution |
1Hz |
1Hz |
Frequency accuracy |
±5×10-6(23℃±3℃) |
±5×10-6(23℃±3℃) |
Output power setting range |
-45dBm~+10dBm |
-55dBm~+10dBm |
System dynamic range
|
(10Hz) (3kHz) 100kHz~1MHz 90dB 60dB 1MHz~10MHz 110 dB 80 dB 10MHz~3GHz 125dB 95dB
|
(10Hz) (3kHz) 100kHz~20MHz 110dB 80dB 20MHz~3GHz 125 dB 95 dB 3GHz~6GHz 123dB 93dB 6GHz~8.5GHz 118dB 88dB |
Reflection tracking |
100kHz~10MHz ±0.030dB 10MHz~3GHz ±0.020dB
|
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Transmission tracking |
100kHz~10MHz ±0.030dB 10MHz~3GHz ±0.020dB
|
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Effective directionality |
100kHz~10MHz 49 dB 10MHz~3GHz 46 dB 100kHz~10MHz 49dB (Option 001) 10MHz~3GHz 46dB (Option 001) |
100kHz~3GHz 46dB 3GHz~6GHz 40dB 6GHz~8.5GHz 38dB
|
Effective source matching |
100kHz~10MHz 44dB 10MHz~3GHz 40dB 100kHz~10MHz 43dB (Option 001) 10MHz~3GHz 21dB (Option 001) |
100kHz~3GHz 36dB 3GHz~6GHz 35dB 6GHz~8.5GHz 33dB
|
Payload matching |
100kHz~10MHz 49 dB 10MHz~3GHz 46 dB 100kHz~10MHz 48dB (Option 001) 10MHz~3GHz 41dB (Option 001) |
100kHz~3GHz 44dB 3GHz~6GHz 40dB 6GHz~8.5GHz 36dB
|
Measurement points |
1 to 16001 |
|
IF bandwidth |
Zui is less than 1Hz; The maximum frequency is 5MHz, with steps of 1, 2, 3, 5, and 7. |
|
Port connector form |
N-type connector (female) system impedance 50 ohms N-type connector (female) system impedance 75 ohms (option 001) |
|
Measure the number of ports |
2 of them |
|
Measure the number of receivers |
4 of them |
|
Reference level amplitude setting |
Setting range: ± 500dB Set resolution: 0.001dB |
|
Reference phase setting |
Setting range: ± 500 ° Set resolution: 0.01 ° |
|
Time base reference output |
Output frequency: 10MHz Output level:+ 10dBm±4dB |
|
Digital Interface |
GP-IB interface, USB interface, Ethernet interface, and VGA display interface |
|
operating system |
Windows XP |
|
Display mode |
10.4-inch high brightness LCD display |
|
Measurement domain |
Frequency domain Time domain |
|
External dimensions |
435 * 233 * 348 (width x height x depth) (including pads, feet, side straps, input/output ports) |
|
power consumption |
150W |
|
Power input form |
50Hz single-phase 220V or 50Hz/60Hz single-phase 110V AC |
|
weight |
16kg |
AV2813A +AV3656A/BTechnical specifications:
parameter |
AV2813A+ AV3656A |
AV2813A +AV3656B |
Frequency range |
100kHz ~ 3GHz |
100kHz ~ 8.5GHz |
Output power setting range |
-15dBm~+10dBm |
-15dBm~+10dBm |
System dynamic range
|
(10Hz) (3kHz) 100kHz~1MHz 80dB 55dB 1MHz~10MHz 100 dB 75dB 10MHz~3GHz 115dB 90dB
|
(10Hz) (3kHz) 100kHz~20MHz 100dB 80dB 20MHz~3GHz 115 dB 93 dB 3GHz~6GHz 113dB 90dB 6GHz~8.5GHz 108dB 85dB |
Reflection tracking |
100kHz~10MHz ±0.050dB 10MHz~3GHz ±0.030dB
|
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Transmission tracking |
100kHz~10MHz ±0.050dB 10MHz~3GHz ±0.030dB
|
100kHz~3GHz ±0.030dB 3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Effective directionality |
100kHz~3GHz 46 dB
|
100kHz~3GHz 46dB 3GHz~6GHz 40dB 6GHz~8.5GHz 38dB |
Effective source matching |
100kHz~3GHz 36dB
|
100kHz~3GHz 36dB 3GHz~6GHz 35dB 6GHz~8.5GHz 33dB |
Payload matching |
100kHz~3GHz 44 dB
|
100kHz~3GHz 44dB 3GHz~6GHz 40dB 6GHz~8.5GHz 36dB |
Port connector form |
N-type connector (female) system impedance 50 ohms |
|
Measure the number of ports |
4 of them |
|
Dimensions (AV2813A) |
435mm * 102mm * 364mm (width x height x depth) (including pads, feet, side straps, input/output ports) |
|
Weight (AV2813A) |
8.0kg |
Ordering Information
host:AV3656A Vector Network Analyzer 100kHz~3GHz
standard configuration:
Serial Number |
name |
describe |
1 |
Power cord components |
Standard three core power cord |
2 |
USB mouse |
|
3 |
Quick User Guide |
|
4 |
certificate of conformity |
|
5 |
Random disc |
|
option:
number |
name |
function |
AV3656A-001 |
75 Ω port impedance system |
|
AV3656A-002 |
N-type test cable (GORE-OSZKUZKU0240) |
Shuangyang, 60cm |
AV3656A-003 |
N-type test cable (GORE-OSZKUZKV0240) |
Yin Yang, 60cm |
AV3656A-004 |
English options |
Button, front panel, label |
AV3656A-005 |
AV20205 N-type Calibration Component |
DC~3GHz |
AV3656A-006 |
AV20204 N-type 75 Ω Calibration Component |
|
AV3656A-007 |
ET06-NMSM-0.8M economical test cable |
N-type to 3.5mm connector, double male, 80cm |
AV3656A-008 |
ET06-NMNF-0.8M economical test cable |
N-type connector, yin-yang, 80cm |
AV3656A-009 |
ET06-NMNM-0.8M economical test cable |
N-type connector, double positive, 80cm |
AV3656A-010 |
197C-NMSM-0.8M Economic Stable Phase Test Cable |
N-type to 3.5mm connector, double male, 80cm |
AV3656A-011 |
197C-NMNF-0.8M Economic Stable Phase Test Cable |
N-type connector, yin-yang, 80cm |
AV3656A-012 |
197C-NMNM-0.8M Economic Stable Phase Test Cable |
N-type connector, double positive, 80cm |
AV3656A-013 |
75 Ω test cable 24-0800-51 M1-51M1 |
|
AV3656A-014 |
AV20402 electronic calibration component |
300kHz~18GHz, N-type (Yin Yang), 2-port |
AV3656A-015 |
AV20403 electronic calibration component |
10MHz~26.5GHz, 3.5mm (Yin Yang), 2 ports |
AV3656A-016 |
AV20405 electronic calibration component |
10MHz~20GHz, 3.5mm (female head), 4-port |
AV3656A-017 |
AV3656 Series Chinese User Manual |
|
AV3656A-018 |
AV3656 Series Chinese Programming Manual |
|
AV3656A-019 |
Front panel jumper |
Support four port expansion and receiver direct test |
AV3656A-020 |
AV2813A Four Port Testing Device |
Option AV3656A-019 is required to support |
AV3656A-021 |
Aluminum alloy transport box |
|
AV3656A-022 |
AV3656 Series English User Manual |
|
AV3656A-023 |
AV3656 Series English Programming Manual |
|
host:AV3656B Vector Network Analyzer 100kHz~8.5GHz
standard configuration:
Serial Number |
name |
describe |
1 |
Power cord components |
Standard three core power cord |
2 |
USB mouse |
|
3 |
Quick User Guide |
|
4 |
certificate of conformity |
|
5 |
Random disc |
|
option:
Number |
name |
function |
AV3656B-001 |
English options |
Button, front panel, label |
AV3656B-002 |
N-type test cable (GORE-OSZKUZKU0240) |
Shuangyang, 60cm |
AV3656B-003 |
N-type test cable (GORE-OSZKUZKV0240) |
Yin Yang, 60cm |
AV3656B-004 |
AV20201 N-type Calibration Kit |
DC~9GHz |
AV3656B-005 |
AV20202 3.5mm Calibration Kit |
DC~9GHz |
AV3656B-006 |
AV32111 waveguide calibration component |
1.72~2.61GHz |
AV3656B-007 |
AV32112 waveguide calibration component |
2.60~3.95GHz |
AV3656B-008 |
AV32113 waveguide calibration component |
3.94~6.00GHz |
AV3656B-009 |
AV32114 waveguide calibration component |
4.64~7.05GHz |
AV3656B-010 |
AV32115 waveguide calibration component |
5.88~8.17GHz |
AV3656B-011 |
AV32116 waveguide calibration component |
7.00~10.0GHz |
AV3656B-012 |
AV20402 electronic calibration component |
300kHz~18GHz, N-type (Yin Yang), 2-port |
AV3656B-013 |
AV20403 electronic calibration component |
10MHz~26.5GHz, 3.5mm (Yin Yang), 2 ports |
AV3656B-014 |
AV20405 electronic calibration component |
10MHz~20GHz, 3.5mm (female head), 4-port |
AV3656B-015 |
AV3656 Series Chinese User Manual |
|
AV3656B-016 |
AV3656 Series Chinese Programming Manual |
|
AV3656B-017 |
AV3656 Series English User Manual |
|
AV3656B-018 |
AV3656 Series English Programming Manual |
|
AV3656B-019 |
Front panel jumper |
Support four port expansion and receiver direct test |
AV3656B-020 |
AV2813A Four Port Testing Device |
Option AV3656B-019 support is required |
AV3656B-021 |
Aluminum alloy transport box |
|
host:AV2813A S parameter testing device+(019 option) 100kHz~8.5GHz
standard configuration:
Serial Number |
name |
describe |
1 |
Power cord components |
Standard three core power cord |
2 |
usb cable |
|
3 |
Semi rigid cable |
6 pieces (2 N-type connectors, 4 3.5mm connectors) |
4 |
3.5mm torque wrench |
|
5 |
Quick User Guide |
|
6 |
certificate of conformity |
|
7 |
Random disc |
|
Options:
|
number |
name |
function |
open up or clear out by poking or jabbing use select piece |
AV2813A-001 |
N-type test cable (GORE-OSZKUZKU0240) |
Shuangyang, 60cm |
AV2813A-002 |
N-type test cable (GORE-OSZKUZKV0240) |
Yin Yang, 60cm |
|
AV2813A-003 |
AV2813A Chinese User Manual |
|
|
AV2813A-004 |
AV3656 Series Chinese Programming Manual |
|
|
AV2813A-005 |
AV3656 Series English Programming Manual |
|
|
AV3656A Four port option
|
AV2813A-006 |
AV20205 N-type Calibration Component |
DC~3GHz |
AV2813A-007 |
ET06-NMSM-0.8M economical test cable |
N-type to 3.5mm connector, double male, 80cm |
|
AV2813A-008 |
ET06-NMNF-0.8M economical test cable |
N-type connector, yin-yang, 80cm |
|
AV2813A-009 |
ET06-NMNM-0.8M economical test cable |
N-type connector, double positive, 80cm |
|
AV2813A-010 |
197C-NMSM-0.8M Economic Stable Phase Test Cable |
N-type to 3.5mm connector, double male, 80cm |
|
AV2813A-011 |
197C-NMNF-0.8M Economic Stable Phase Test Cable |
N-type connector, yin-yang, 80cm |
|
AV2813A-012 |
197C-NMNM-0.8M Economic Stable Phase Test Cable |
N-type connector, double positive, 80cm |
|
AV3656B Four port option |
AV2813A-013 |
AV20201 N-type Calibration Kit |
DC~9GHz |
AV2813A-014 |
AV20202 3.5mm Calibration Kit |
DC~9GHz |
|
AV2813A-015 |
AV32111 waveguide calibration component |
1.72~2.61GHz |
|
AV2813A-016 |
AV32112 waveguide calibration component |
2.60~3.95GHz |
|
AV2813A-017 |
AV32113 waveguide calibration component |
3.94~6.00GHz |
|
AV2813A-018 |
AV32114 waveguide calibration component |
4.64~7.05GHz |
|
AV2813A-019 |
AV32115 waveguide calibration component |
5.88~8.17GHz |
|
AV2813A-020 |
AV32116 waveguide calibration component |